6
-
Item
Model
SCM45ZD-S
Cooling capacity
W
4500 (700 ~ 5600)
Heating capacity
W
5600 (700 ~ 6800)
Power source
1 Phase 220/230/240V 50Hz
Power consumption
Cooling
W
1390 (200 ~ 2160)
Heating
1540 (200 ~ 2340)
Running current
Cooling
6.4/6.1/5.9
Heating
A
7.1/6.8/6.5
Sound level
Cooling : 45/45/47 Heating : 47/47/49
Noise level
Power level
dB
Cooling : 60/60/62 Heating : 62/62/64
Exterior dimensions
Height
×
Width
×
Depth
mm
640
×
850
×
290
Color
Stucco white
Net weight
kg
44
Refrigerant equipment
Compressor type & Q’ty
5CS102XFD [Scroll]
×
1
Motor
kW
0.7
Starting method
Direct start
Refrigerant control
Capillary tubes
+
Electric expansion valve
Refrigerant
kg
R410A 1.6 (Pre-charged up to the piping length of 20m)
Refrigerant oil
R
0.48 (RB68A)
Air handling equipment
Fan type & Q’ty
Propeller fan
×
1
Motor
W
35
Air flow (at high)
CMM
40
Shock & vibration absorber
Rubber (for compressor)
Safety equipment
Size
×
Core
×
Number
mm (in)
Liquid line:
φ
6.35 (1/4
″
)
×
2
Gas line:
φ
9.52 (3/8
″
)
×
2
Connecting method
Flare connecting
Attached length piping
—
Insulation
Necessary (Both Liquid & Gas lines)
Power source supply
Terminal block (Screw fixing type)
Size
×
Core number
1.5 mm
2
×
4 cores (Including earth cable)
×
2
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Installation sheet, Manual instruction
SKM22, 25, 28, 35 type,
Indoor units to be combined
STM25, 35 type,
SRRM25, 35 type
(2)
Outdoor unit
Model SCM45ZD-S
Compressor overheat protection, Overcurrent protection
Serial signal error protection
Notes (1) The data are measured at the following conditions.
Refrigerant
piping
Connec-
tion wiring
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27ºC
19ºC
35ºC
24ºC
ISO-T1, JIS C9612
Heating
20ºC
–
7ºC
6ºC
ISO-T1, JIS C9612
(2) The values for capacity and power consumption shown in a range ( ) indicate the minimum and maximum of the range.
(3) If the piping length exceeds 20 m, additional charging is required. (20g/m)