45
1
ON
2 3 4 5 6
Error details
(No error)
Over voltage
Under voltage
Input current sensor error
Abnormal power synchronous signal
ACTM error
Code
00
01
02
04
08
20
U9 Error details (To be shown while
error call is deferred.)
Code
display
1
ON
2 3 4 5 6
Requested capacity step (Q STEP)
0 to 7
0 to 7
Step
SW2 setting
Display detail
Explanation for display
Unit
:
Comp. surface temperature (TH33)
3 to 217 <VHA2(-BS)>
−52•to•221•<VHA2R1/R3/R4/R5(-BS)>
3 to 217 <VHA2(-BS)>
−52•to•221•<VHA2R1/R3/R4/R5(-BS)>
(When the temperature is 100
:
or more, the
hundreds digit, tens digit and ones digit are
displayed by turns.)
(Example) When 130
:
;
0.5 s 0.5 s 2 s
1
ON
2 3 4 5 6
1
30
Display examples for multiple errors:
Overvoltage (01) + Undervoltage (02) = 03
Undervoltage (02) + Power-sync signal error (08) = 0A
Input current sensor error (04) + ACTM error (20) = 24
OCH465D