OC275-21
2. INDOOR UNIT CONTROL
2-1COOL operation
<COOL operation time chart>
Thermostat
Operation starts by
POWER button
ON.
ON
OFF
Indoor fan
ON
OFF
Auto vane
ON
OFF
Compressor
ON
OFF
w
1 Even if the room temperature rises above the set temperature during this period, the compressor will not start until
this period has ended.
LOW or HIGH
CLOSE
CLOSE
LOW or HIGH
Depends on remote controller setting
MIN. 3 minutes
w
1
Room temperature
becomes equal to
set temperature.
Room temperature
rises above set
temperature.
Operation stops by
POWER button
OFF.
<How to operate>
1
Press POWER ON/OFF button.
2
Press MODE button to set operation mode to COOL.
3
Set desired temperature with or button.
NOTE: 1. Set temperature changes by 2 °F in the range 65~87 °F
each TEMP
or button is pressed.
2. Set temperature is displayed on the LCD.
ON/OFF
TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESET
SET
CLOCK
FAN
˚F
COOL
AM
OC275--1.qxp 01/12/14 3:06 PM Page 21