272
(9) Module-based parameter data (address: 0126
H
to 0128
H
, 0146
H
to 0148
H
)
Address
Name
Description
Default
CH1
CH2
0126
H
0146
H
Counter function
selection
• Set the counter function which becomes valid when the value in CH
Operation mode setting (address: 0120
H
, 0140
H
) is Normal Mode (0).
• The following shows the setting range.
0: Count Disable Function
1: Latch Counter Function
2: Sampling Counter Function
3: Periodic Pulse Counter Function
4: Count disable/Preset/replace Function
5: Latch counter/Preset/replace Function
• The reflection timing of the setting value
When Initial data setting request flag (RY9) is turned off then on
0
0127
H
0147
H
Function input logic
setting
• Set the logic setting of CH
Function input terminal (FUNC1, FUNC2).
• CH1 FNC LED and CH2 FNC LED turn on with any setting value when a
voltage is applied.
• The following shows the setting range.
0: Positive Logic
1: Negative Logic
• The reflection timing of the setting value
When Initial data setting request flag (RY9) is turned off then on
0
0128
H
0148
H
Latch counter input
logic setting
• Set the logic setting of CH
Latch counter input terminal (LATCH1,
LATCH2).
• CH1 LAT LED and CH2 LAT LED turn on with any setting value when a
voltage is applied.
• The following shows the setting range.
0: Positive Logic
1: Negative Logic
• The reflection timing of the setting value
When Initial data setting request flag (RY9) is turned off then on
0
Summary of Contents for NZ2GFCF-D62PD2
Page 1: ......
Page 2: ......
Page 54: ...52 Memo ...
Page 206: ...204 Memo ...
Page 303: ......
Page 304: ......