Disassembling procedures
In reverse of assembling procedures.
●
Assembling procedures
1.Connect M007 to M083. (Either direction of the connector can be connected.)
2.Screw the M083 with the one screw(
Ⓐ
).
3.Latch the hook of M007 to the hook.
4.Connect M007 to M081.
M3X6
0.7 +0.2/-0.1
Ⓐ
Tighten torque(N
・m)
Screw
No.
M007: LEAD-CONNECTOR 4P
M083: ASSY-PCB-SENSOR
Ⓐ
M081: ASSY-PCB-ANALOG
Fig. A
Pass the Lead-Connector
to area A of Fig. A.
Latch the Lead-Connector
to the hook.
Hook latch position.
Assembling Angle of M083
Remove the adsorption sheet