7

Operation state

This shows that the air conditioner is operating to reach the
target temperature. Please wait until the target temperature
is obtained.

This shows that the room temperature is approaching the
target temperature.

ON/OFF

FAN

TOO

WARM

TOO

COOL

VANE

MODE

    STOP

     START

HR.

MIN.

I FEEL COOL

DRY

AM

PM

CLOCK

˚C

AMPM

HEAT

RESET CLOCK

Details of operation

According to the room temperature when the operation starts, the opera-
tion mode is automatically set to COOL, DRY or HEAT. However, when
operation is started again within 2 hours after it is stopped, the same
operation mode before the operation is stopped is selected. The opera-
tion mode selected first is not changed even if the room temperature
changes. If the operation mode does not match the room condition, se-
lect the appropriate operation mode by pressing the 

MODE

 button.

Details of auto operation

Room temperature

Operation mode

Target temperature

when started

 (initial state)

About 77 °F or higher

COOL

About 75 °F

About 77 °F - 73 °F

DRY

About 73 °F or lower

HEAT

About 79 °F

FAN

VANE

HEAT

MODE

ECONO COOL

    STOP

     START

HR.

MIN.

I FEEL COOL

DRY

I FEEL... AUTO OPERATION

With the “

 (I FEEL...)” auto operation mode,

the optimum room condition can be set automati-
cally with a one-touch operation.

To start operation:

Press the 

ON/OFF

 button.

When the “

 (I FEEL...)” mode is selected, the air

conditioner is automatically controlled at the optimum
temperature.

To stop operation:

Press the 

ON/OFF

 button.

If you feel slightly warm:

Press the 

TOO

WARM

 button to lower the tempera-

ture.

One press lowers the temperature by about 2 °F.

If you feel slightly cool:

Press the 

TOO

COOL

 button to raise the tempera-

ture.

One press raises the temperature by about 2 °F.

When  “  (I FEEL...)” is not selected, press
the 

MODE

 button until it is set.

Each time the button is pressed, the operation mode is
changed in sequence: 

 (I FEEL...) 

 

 (COOL) 

   (DRY)

 

 (HEAT)

NOTE

COOL: When the room temperature is 4 °F higher than the set temperature, the set temperature may not be changed

since the air conditioner is operating to reach the target (set) temperature. In this case, please wait until
the room temperature drops to within 4 °F of the set temperature and then change the set temperature.

HEAT: When the room temperature is 4 °F lower than the set temperature, the set temperature may not be

changed since the air conditioner is operating to reach the target (set) temperature. In this case,
please wait until the room temperature rises to within 4 °F of the set temperature and then change the
set temperature.

Details of display on the indoor unit

The operation indicator at the right side of the indoor unit indicates
the operation state.

MSZ09UN

MSZ12UN

Operation indicator lamp

MSZ09UN

Indication

Difference between target

temperature and room temperature

About 4 °F or more

About 4 °F or less

Operation 

Indicator

Lighted

 

Not lighted

Description of “AUTO RESTART FUNCTION”

These units are equipped with an auto restart function. When the main power is turned on, the air conditioner will start
operation automatically in the same mode as the one set with the remote controller before the shutoff of the main power.

If the unit was set to off with the remote controller before the shutoff of the main power, it will remain stopped even after
the main power is turned on.

If the unit was in the emergency operation before the shutoff of the main power, it will start operation, when main power
comes on, in the same mode as the one set with the remote controller before the emergency operation.

If the unit is operated in “I FEEL ...” mode before power failure, the operation is not stored in the memory. In “I FEEL ...”
mode, the operation is decided by the initial room temperature at (re)start.

Since the air conditioner has been shipped from the factory with the COOL mode saved in the memory for auto restart
function, it starts cooling operation when the user turns on the main power for the first time after installation.

Description of “I FEEL...” mode

Room temperature:
About 77 °F or higher

 COOL

About 77 °F - 73 °F

 DRY

About 73 °F or lower

 HEAT

Lighted

  

Not lighted

Operation Indicator

MSZ12UN

Operation state

This shows that the air conditioner is operating to reach the
target temperature. Please wait until the target temperature
is obtained.

This shows that the room temperature is approaching the
target temperature.

Indication

Difference between target

temperature and room temperature

About 4 °F or more

About 4 °F or less

Summary of Contents for MSZ09UN

Page 1: ......

Page 2: ...IS NOT GOING TO BE USED FOR A LONG TIME 10 MAINTENANCE 11 CLEANING THE AIR FILTER AND THE DEODORIZING FILTER OPTION 11 REPLACEMENT OF THE DEODORIZING FILTER OPTION AIR CLEANING FILTER OPTION 12 BEFORE...

Page 3: ......

Page 4: ...to be operated in an abnormal condition it may cause a fire trouble etc In this case consult your dealer Do not insert your finger or a stick etc into the air inlet outlet Since the fan rotates at hi...

Page 5: ......

Page 6: ...room with high hu midity 80 RH or more for a long time water condensed in the air conditioner may drop and wet or damage furniture etc Do not step onto an un stable bench when main taining the unit e...

Page 7: ......

Page 8: ...ing filter Gray sponge type OPTION Air filter Vertical vane Operation section When the front panel is opened Front panel Air inlet Remote control receiving section Remote controller Display section MS...

Page 9: ......

Page 10: ...P START HR MIN I FEEL COOL DRY AMPM CLOCK AMPM RESET CLOCK F Operation select button Fan speed control button On timer button CLOCK set button HR button MIN button Time set button Vane control button...

Page 11: ......

Page 12: ...ake out all batteries when the remote controller is not going to be used for a long time Dispose of exhausted batteries in the correct man ner on nt in is in When the remote controller cannot be used...

Page 13: ......

Page 14: ...TO RESTART FUNCTION These units are equipped with an auto restart function When the main power is turned on the air conditioner will start operation automatically in the same mode as the one set with...

Page 15: ......

Page 16: ...N Refer to page 7 HEAT Comfortable warmth depends on the temperature difference between the indoor and the outdoor It is recommended that the set temperature in the heating operation does not differ f...

Page 17: ......

Page 18: ...HEAT When the air flow temperature is too low When the air flow temperature rises the air is blown out horizontally the air is blown out downwards 2 COOL DRY The air is blown out horizontally To chang...

Page 19: ......

Page 20: ...ng time Dirt may collect and this may cause a fire 3 Remove the batteries from the remote con troller CAUTION To prevent liquid leakage take out all batteries when the remote controller is not going t...

Page 21: ......

Page 22: ...e detergent 3 After washing with water lukewarm water dry the deodorizing filter well in the shade Do not expose the deodorizing filter to direct sunlight or heat from a fire when drying it 4 Install...

Page 23: ......

Page 24: ...the breaker Otherwise the electrical parts may be damaged 3 Isn t the ON timer set Even if the above items are checked when the air conditioner does not recover from the trouble stop using the air co...

Page 25: ......

Page 26: ...to blow out warm air Defrosting of the outdoor unit is being done Defrost ing operation Since this is completed in 10 minutes please wait When the external temperature is too low and humid ity is too...

Page 27: ......

Page 28: ...bject around the air outlet of the outdoor unit This may lower the capacity or increase the volume of the operating sound If an abnormal sound is heard during operation consult your dealer Relocation...

Page 29: ......

Page 30: ...3400 Lawrenceville Suwanee Road Suwanee Georgia 30024 Toll Free 800 433 4822 Toll Free Fax 800 889 9904 www mrslim com Specifications are subject to change without notice...

Reviews: