background image

5

FAN

VANE

MODE

ECONO COOL

    STOP

     START

HR.

MIN.

I FEEL COOL

DRY

WIDE VANE

LONG

HEAT

RESET CLOCK

Remote controller

How to set the batteries and the current
time

1

Remove the front lid and insert batteries.
Then reattach the front lid.

Insert the minus pole of the batteries first.
Check if the polarity of the batteries is correct.

2

Press the RESET button.

If the RESET button is not pressed, the remote con-
troller may not operate correctly.

3

Press the CLOCK set button.

4

Press the 

HR.

 and 

MIN.

 buttons (TIME SET

buttons) to set the current time.

Each time the 

HR.

 button is pressed, the set time

increases by 1 hour, and each time the 

MIN.

 button

is pressed, the set time increases by 1 minute.

5

Press the CLOCK set button again and close
the front lid.

Press using a
thin stick.

Press using a
thin stick.

Insert the minus pole
of the batteries first.

Remote control-
ler holder

1

Press the EMERGENCY OPERATION switch.

Each time the EMERGENCY OPERATION switch is
pressed, the unit will operate in order of EMER-
GENCY COOL MODE, EMERGENCY HEAT MODE
and STOP MODE.
However, when the EMERGENCY OPERATION
switch is once pressed, the unit will operate in test
run for 30 minutes and then the operation mode
shifts to EMERGENCY MODE.

Details of EMERGENCY MODE are as shown be-
low. However, the temperature control does not
work for 30 minutes in test run and the unit is set
to continuous operation. The fan speed is set to
High in test run and shifts to Medium after 30 min-
utes.

Operation mode

COOL

HEAT

Set temperature

24°C

24°C

Fan speed

Medium

Medium

Horizontal vane

Auto

Auto

Vertical vane

Front

Front

The operation mode is indicated by the Operation
Indicator lamp on the indoor unit as following fig-
ure.

Operation Indicator lamp

When the remote controller cannot be used (emergency operation)

When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation
can be done using the EMERGENCY OPERATION switch.

EMERGENCY HEAT

EMERGENCY COOL

STOP

Handling of the remote controller

The range that the signal can reach is about 6 m when
the remote controller is pointed at the front of the in-
door unit.

When a button is pressed, one or two beeps will be
heard from the indoor unit. If no sound is heard, op-
erate again.

Use the remote controller carefully.
If it is dropped, thrown or it gets wet, the remote con-
troller may not operate.

When installing on a wall, etc.

Install the remote controller holder in a position where
the signal reception sound (beep) can be heard from
the indoor unit when the 

ON/OFF

 button is pressed.

How to install/remove the remote controller

Installing

:Insert the remote controller downward.

Removing :Pull it up.

Dry-cell batteries

 Reference for replacing batteries

Replace the batteries with new AAA alkaline batteries
in the following cases:

·

When the indoor unit does not respond to the remote
control signal.

·

When the display on the remote controller becomes
dim.

·

When a button of the remote controller is pressed, all
displays appear on the screen, and then disappear
immediately.

Do not use manganese batteries. The remote controller
could malfunction.

The service life of an alkaline battery is about 1 year.
However, a battery whose time limit is approaching
may be exhausted soon. The recommended usable
time limit is indicated (month/year) on the bottom of
the battery.

To prevent liquid leakage, take out all batteries when
the remote controller is not going to be used for a
long time.

 CAUTION:

If liquid from the batteries gets onto your skin or
clothes, wash it well with clean water.
If liquid from the batteries gets into your eyes, wash
them well with clean water and consult a doctor at
once.

Do not use rechargeable batteries.

Replace the 2 batteries with new ones of the same
type.

Dispose of exhausted batteries in the correct man-
ner.

PREPARATION BEFORE OPERATION

Operation Indicator

Operation Indicator

Operation Indicator

2

To stop the emergency operation, press the
EMERGENCY OPERATION switch once (in
case of EMERGENCY HEAT MODE) or twice
(in case of EMERGENCY COOL MODE).

Summary of Contents for MSZ-A18 YV Series

Page 1: ...Mitsubishi room air conditioner ely be sure to read this operating instructions fully for later reference d from your dealer and check that the purchased ered correctly installed by the customer Safe...

Page 2: ...dity e g leaving a door or window open In the cooling mode if the unit is operated in a room with high humidity 80 RH or more for a long time water condensed in the air conditioner may drop and wet or...

Page 3: ...or lamp Air inlet back and side Piping Drainage hose Air outlet Drain outlet Catechin air filter ide temperature less than 10 C in the cooling mode operated at low outside temperature less than 10 C w...

Page 4: ...operation mode the set temperature and the fan speed are stored in the memory If a power failure occurs or the main power is turned off during operation Auto restart function sets automatically to st...

Page 5: ...thrown or it gets wet the remote con troller may not operate When installing on a wall etc Install the remote controller holder in a position where the signal reception sound beep can be heard from t...

Page 6: ...rget set temperature In this case please wait until the room temperature drops to within 2 C of the set temperature and then change the set temperature HEAT When the room temperature is 2 C lower than...

Page 7: ...High notch to cool heat the room more If the operating sound of the air conditioner disturbs your sleep use the Low notch To change the AIR FLOW blowing direction vertically press the VANE button Eac...

Page 8: ...w are available Programming timer operation The ON timer and the OFF timer can be used in combination The timer of the set time that is reached first will operate first mark indicates the order of tim...

Page 9: ...d during operation it may cause an injury Cleaning the indoor unit Clean the unit using a soft dry cloth If the dirt is noticeable wipe the unit with a cloth soaked in a solution of mild detergent dil...

Page 10: ...hen replace echin that is contained in tea The catechin air filter deodorizes ammonia and acetaldehyde Moreover it restraints the activity of About once every 4 months 1 Install a new air cleaning fi...

Page 11: ...ng the air inlet or or outdoor unit open Page 10 hausted Page 5 of the batteries correct he remote controller of other being pressed oner start operating again er had operated before the se models are...

Page 12: ...uld not be done by the customer If this is done incorrectly it may cause a fire an electric shock or an injury from the unit falling water leaking etc Consult your dealer Disposal To dispose of this p...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...HEAD OFFICE MITSUBISHI DENKI BLDG 2 2 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79Y329H01...

Reviews: