58
MSH-30RV -
MUH-30RV -
E1
E1
Part name
Figure
Check method and criterion
Measure the resistance between the terminals with a tester.
(Part temperature –10˚C ~ 40˚C)
Compressor(MC)
INNER
PROTECTOR
160
i
5
:
ON
90
i
10
:
OFF
Indoor fan motor(MF)
INNER
PROTECTOR
135
i
5
:
ON
Normal
Terminal
C – R
C – S
0.58
"
~ 0.71
"
1.39
"
~ 1.70
"
Abnormal
Open or
short-circuit
Measure the resistance with a tester.
(Part temperature –10˚C ~ 40˚C)
Color of lead wire
WHT – BLK
BLK – RED
Abnormal
Open or
short-circuit
Normal
133
"
~ 144
"
153
"
~ 165
"
Measure the resistance with a tester.
(Part temperature 10˚C ~ 30˚C)
Normal
8 k
"
~ 20 k
"
Abnormal
Open or short-circuit
Room temperature
thermistor(RT11)
Indoor coil thermistor
(RT12(main), RT13(sub))
Discharge temperature
thermistor(RT62)
Ambient temperature
thermistor(RT63)
Outdoor fan motor(MF)
INNER
PROTECTOR
145
i
8
:
ON
( 88
i
15
:
OFF
w
)
Horizontal vane
motor(MV1)
Vertical vane
motor(MV2)
R.V. coil(21S4)
LEV(Expansion valve)
Measure the resistance with a tester.
Before measurement, hold the thermistor with your hands to warm it up.
(Part temperature 0˚C ~ 40˚C)
Normal
120 k
"
~ 800k
"
Abnormal
Open or short-circuit
Normal
5 k
"
~ 60 k
"
Abnormal
Open or short-circuit
Motor part
Sensor part
Measure the resistance between the terminals with a tester.
(Part temperature 10˚C ~ 30˚C)
Color of lead wire
BRN – YLW
YLW – GRY
Abnormal
Remain 0V or 5V
Normal
4.5 ~ 5.5V
Measure the voltage power ON.
(When fan revolved one time)
0V
➔
5V
➔
0V
(Approx.)
Measure the resistance between the terminals with a tester.
(Part temperature –10˚C ~ 40˚C)
Color of lead wire
WHT – BLK
BLK – YLW
YLW – RED
Abnormal
Open or
short-circuit
Normal
55.4
"
~ 67.7
"
49.3
"
~ 60.3
"
22.9
"
~ 28.0
"
Normal
282
"
~ 306
"
Abnormal
Open or short-circuit
Measure the resistance between the terminal with a tester.
(Part temperature 10
°
C ~ 30
°
C)
Measure the resistance between the terminals with a tester.
(Part temperature –10˚C ~ 40˚C)
Normal
2.673 k
"
~ 3.268 k
"
Abnormal
Open or short-circuit
Color of lead wire
WHT – RED
RED – ORN
YLW – BRN
BRN – BLU
Abnormal
Open or
short-circuit
Normal
30.3
"
~ 37.0
"
Measure the resistance with a tester.
(Part temperature : –10˚C ~ 40˚C)
Measure the resistance with a tester.
(Part temperature –10˚C ~ 40˚C)
Normal
5 k
"
~ 60 k
"
Abnormal
Open or short-circuit
Defrost thermistor
(RT61)
BLK
RED
WHT
GR
Y
YL
W
BRN
w
Reference value
P
R
C
S
RED
BLK
WHT
MAIN
AUX.
ORN
BLU
YLW
RED
PNK
ROTOR
RED ORN WHT
YLW
BLK
MAIN
AUX.1 AUX.2
C
P
MAIN
AUX.
P
LEV
WHT
6
RED
1
ORN
4
YL
W
5
BRN
2
BLU
3
:INNER PROTECTOR