background image

1.2

Dimensions and Specifications

1.2.1

FX-50DU-TK(S)-C Dimensions

1.2.2

Unit Characteristics

MODEL

SCREEN TYPE

KEYS

IP RATING

FX-50DU-TK-C

320 

 240 dots

40 

 15 chars

96 

 72 mm

TOUCH SCREEN

Monochrome LCD

Complete Touch

Key operation

16 

 8 zones

(32 per 32

global)

IP 65

(Based on

manufacturer’s

own tests)

FX-50DU-TKS-C

8 color LCD

1.2.3

Basic Specifications

MODEL

POWER SUPPLY

DIMENSIONS (mm, inch)

WEIGHT

W

H

D

kg (lbs)

FX-50DU-TK-C

24V DC

+10%

-15%

220mA

170 (6.69)

130 (5.12)

66 (2.60)

1.0 (2.2)

(includes brackets:

0.1 (0.22))

FX-50DU-TKS-C

250mA

66 (2.60)

5.5

(0.22)

120

(4.72)

about 110 (4.33)

130

(5.12)

160 (6.30)

170 (6.69)

Graphic FX-50DU-TK(S)-C Units

Introduction    1

1 – 3

Summary of Contents for MELSEC-F FX-50DU-TK-C

Page 1: ...HARDWARE MANUAL GRAPHIC FX 50DU TK S C UNITS MELSEC F ...

Page 2: ...e attempting to install or use the unit If in doubt at any stage during the installation of the FX 50DU TK S C always consult a professional electrical engineer who is qualified and trained to the local and national standards If in doubt about the operation or use of the FX 50DU TK S C please consult the nearest Mitsubishi Electric distributor This manual is subject to change without notice ...

Page 3: ...nd diagrams shown in this manual are intended only as an aid to understanding the text not to guarantee operation Mitsubishi Electric will accept no responsibility for actual use of the product based on these illustrative examples Owing to the very great variety in possible application of this equipment you must satisfy yourself as to its suitability for your specific application ...

Page 4: ...GRAPHIC FX 50DU TK S C UNITS Hardware Manual Manual number JY992D64301 Manual revision A Date January 1997 Graphic FX 50DU TK S C Units i ...

Page 5: ...d be trained to use that product in a safe and co ordinated manner in compliance to established safety practices The operators should also be familiar with all documentation which is connected with the actual operation of the completed equipment Note the term completed equipment refers to a third party constructed device which contains or uses the product associated with this manual Note s on the ...

Page 6: ...The following variations of the FX 50DU TK S C conform to the identified standards Graphic FX 50DU TK S C Units iii ...

Page 7: ...Power Terminals 2 2 2 2 RS232C Connector 2 2 2 3 RS422 Connector 2 2 3 Installation 3 1 Product Outline 3 2 3 2 FX 50DU TK S C Dimensions 3 3 3 3 Environment Specification 3 3 3 4 Data Access Unit Mounting 3 4 3 5 Control Devices 3 5 4 General Wiring 4 1 Wiring Cautions 4 2 4 2 Termination at screw terminals 4 2 4 3 Power Supply wiring 4 2 4 4 Power Supply Wiring Cautions 4 2 4 5 Communication Cab...

Page 8: ...1 Introduction 2 Terminal Layouts 3 Installation Notes 4 Wiring 5 Diagnostics 6 Index Graphic FX 50DU TK S C Units Introduction 1 1 1 ...

Page 9: ...ns and installation instructions for the following graphic data access units FX 50DU TK C monochrome FX 50DU TKS C STN 8 colors 1 1 The Complete Family Of Graphic Data Access Units FX 25DU E FX 30DU E FX 40DU TK E Graphic FX 50DU TK S C Units Introduction 1 1 2 ...

Page 10: ...peration 16 8 zones 32 per screen 32 global IP 65 Based on manufacturer s own tests FX 50DU TKS C 8 color LCD 1 2 3 Basic Specifications MODEL POWER SUPPLY DIMENSIONS mm inch WEIGHT W H D kg lbs FX 50DU TK C 24V DC 10 15 220mA 170 6 69 130 5 12 66 2 60 1 0 2 2 includes brackets 0 1 0 22 FX 50DU TKS C 250mA 66 2 60 5 5 0 22 120 4 72 about 110 4 33 130 5 12 160 6 30 170 6 69 Graphic FX 50DU TK S C U...

Page 11: ...g into a panel A seal is also supplied and when all mounting brackets are properly fitted IP 65 is possible 1 4 Optional Accessories For communication with an FX or A system the FX 40DU CAB cable is required For programming and set up the FX PCS DU AT C software can be used Please see the appropriate manuals for more information Figure 1 1 F2 40BL Figure 1 2 Mounting Brackets 6 Figure 1 3 Seal Fig...

Page 12: ...g and screen data Must be Epsom ESC P compatible E IBM PC compatible to create read and write screen data FX PCS DU AT C software F EPROM Writer to store screen data G EPROM Type 27C1001 or equivalent 1 5 2 Connection Details REF 1 FX 40DU CAB 2 FX 40DU CAB FX 20P CADP 3 4 5 F2 232CAB or compatible RS232 cable 6 Connect according to the specifications of the ROM Writer 7 After programming the EPRO...

Page 13: ...mple D only DISPLAY LIST Show sampled data as a list DISPLAY GRAPH Show sampled data as a graph CLEAR DATA YES NO ALARM MODE DISPLAY STATUS Display acknowledge active alarms DISPLAY HISTORY Alarm occurrence history DISPLAY FREQUENCY Alarm occurrence frequency CLEAR HISTORY YES NO TEST MODE USER SCREEN Show programmed screens including common screen DATA BANK View set data bank values OTHER MODE SE...

Page 14: ...reens ENGLISH JAPANESE CHINESE TRADITIONAL CHINESE SIMPLIFIED ENGLISH BOLD PLC TYPE FX SERIES FX0 FX0S FX0N FX FX2C A SERIES All A MPUs except QnA and A0J2 SERIAL PORT RS232C SPEED 300 9600 baud DATA BIT 7 or 8 STOP BIT 1 or 2 PARITY Odd Even None HANDSHAKING DSR DTR XON XOFF PRINTER USE or DON T USE OPENING SCREEN DISPLAY TIME seconds MAIN MENU CALL KEY Screen location to return to SELECT MODE me...

Page 15: ...MEMO Graphic FX 50DU TK S C Units Introduction 1 1 8 ...

Page 16: ...1 Introduction 2 Terminal Layouts 3 Installation Notes 4 Wiring 5 Diagnostics 6 Index Graphic FX 50DU TK S C Units Terminal Layouts 2 2 1 ...

Page 17: ...o directly program the MPU using standard programming software such as MEDOC 2 3 RS422 Connector The RS422 connector is used to connect the FX 50DU TK S C to the MPU being monitored The FX 40DU CAB is required for this purpose Note The FX 40DU CAB is provided separately 24VDC Screw size M3 0 12 inch Figure 2 1 FX 50DU TK S C power terminals Figure 2 2 25 pin D shell female RS232C RS422 RS232C RS42...

Page 18: ...1 Introduction 2 Terminal Layouts 3 Installation Notes 4 Wiring 5 Diagnostics 6 Index Graphic FX 50DU TK S C Units Installation Notes 3 3 1 ...

Page 19: ...nes 8 color FX 50DU TKS C or monochrome FX 50DU TK C Touch key pad 16 8 zones 32 per screen 32 global B Power LED ON when power is applied RS232C connector Used for sending alarm or sampled data to a printer or to upload download data to from a computer RS422 connector Used to communicate with the monitored MPU FX 40DU CAB required Power terminals 24v DC and earth C Access door to EPROM socket for...

Page 20: ...0G Noise immunity tested by noise simulator 1000 Vpp 1µs at 30 to 100Hz Dielectric withstand voltage tested between External I O pins power terminals and ground 500V AC for over 1min Insulation resistance tested between External I O pins power terminals and ground 500V DC at more than 5MΩ Ground not required where impossible Class 3 100Ω Operating ambience to be free of corrosive gases Dust should...

Page 21: ...es on the unit 5 with the lugs facing towards the back 6 of the unit The screws can then be inserted into the brackets 7 and tightened up to the panel Tighten to a torque of 3 to 5 kg cm 2 6 to 4 3 inlb 4 fit all 6 brackets Figure 3 3 Securing with brackets 66 2 60 120 4 72 5 0 20 or less about 110 4 33 FX 40DU CAB seal Figure 3 4 Allowed clearances 5 fit hook into hole 6 lugs backwards 7 insert s...

Page 22: ... software Bit Devices Description Direction Mn Clear Alarm History MPU ð DU Mn 1 Alarm On MPU ï DU Mn 2 Back Light Off after set time MPU ð DU Mn 3 Clear Sampling MPU ð DU Mn 4 Sampling Active MPU ï DU Mn 5 Data Change in Progress User Screen Mode MPU ï DU Mn 6 Battery Low MPU ï DU Mn 7 Not Used Data Devices Description Direction Dn Dn 1 Dn 2 PLC Request Screens MPU ð DU Dn 3 Dn 4 Dn 5 Current Dis...

Page 23: ...MEMO Graphic FX 50DU TK S C Units Installation Notes 3 3 6 ...

Page 24: ...1 Introduction 2 Terminal Layouts 3 Installation Notes 4 Wiring 5 Diagnostics 6 Index Graphic FX 50DU TK S C Units Wiring 4 4 1 ...

Page 25: ...ion 4 3 Power Supply wiring The power supply for these units can be connected in one of two ways First by connecting to the service supply of the FX MPU and secondly from and independent source Both methods are shown opposite 4 4 Power Supply Wiring Cautions The wires used for the power supply wiring should have a cross sectional area of at least 0 75mm2 0 001in2 to ensure that there is no voltage...

Page 26: ... 2 Amps B MPU Service Supply 24V C External 24V Power Supply SELV D Earth class 3 Table 4 1 Feature Table Spec Power Supply Voltage 24V DC 10 15 Power Supply Ripple 200 mV or less Current Consumption FX 50DU TK C 220 mA FX 50DU TKS C 250 mA Momentary Power Down 5 ms or less Recommended Fuse Rating 2A Table 4 2 Power Supply Specification D Graphic FX 50DU TK S C Units Wiring 4 4 3 ...

Page 27: ...K S C it is necessary to earth the FX 40DU CAB cable at the MPU Some printers and PCs use a 9 pin connector for RS232C A standard conversion cable as shown opposite can be used Alternatively the cable F2 232CAB 1 can be used This cable already has a 9 pin connector for use with such printers and computers Figure 4 4 FX 40DU CAB connections Figure 4 5 F2 232CAB connections Figure 4 6 Convert 25 pin...

Page 28: ...1 Introduction 2 Terminal Layouts 3 Installation Notes 4 Wiring 5 Diagnostics 6 Index Graphic FX 50DU TK S C Units Diagnostics 5 5 1 ...

Page 29: ...controller power ON Defective cable connection or defective cable Check the cable connection connect properly Or replace the cable A CPU Error has occurred at the MPU Remedy the cause of the CPU Error and restart the system Screen data sampled data alarm history or data bank data cannot be found Check for references to undefined data and either create the data or remove the reference User Mode sta...

Page 30: ...D instead of a bit device X Y etc Refer to the DU software manual to check the devices that can be used Data Entry The data value entered is outside the range of possible values for this object Check the allowed range for this object and re enter SET NUMBER IS INCORRECT SET DEVICE IS INCORRECT PLC PROGRAM IS DESTROYED Graphic FX 50DU TK S C Units Diagnostics 5 5 3 ...

Page 31: ... light 5 2 3 Battery Replacement The battery life is about 5 years Switch OFF the power to the DU and open the User Access panel at the back of the unit Remove the battery A from the holder B and disconnect at C Connect C the new battery and re fit into the holder B Close the cover and restore the power The new battery should be connected within 30 second of removing the old one to retain all the ...

Page 32: ...1 Introduction 2 Terminal Layouts 3 Installation Notes 4 Wiring 5 Diagnostics 6 Index Graphic FX 50DU TK S C Units Index 6 6 1 ...

Page 33: ...1 4 4 F2 40BL See Battery Function List Menu Options 1 6 Fuse Rating 4 3 FX 40DU CAB 4 4 Connections 4 4 FX PCS DU AT C 1 4 3 5 G General Maintenance 5 4 Grounding 3 3 4 2 H Humidity 3 3 I Installation 3 1 Insulation Resistance 3 3 Introduction 1 1 IP Rating 1 3 K Keys 1 3 L LCD Display 5 4 Life 5 4 M Maintenance 5 4 Menu Options 1 6 Mounting 3 4 Clearances 3 4 Cut out Dimensions 3 4 MPU Service S...

Page 34: ...pecification Basic 1 3 Environmental 3 3 Power Supply 1 3 4 3 T Temperature Operating 3 3 Storage 3 3 Terminal Layouts 2 1 Power Terminals 2 2 RS232C Connector 2 2 Trouble Shooting Error Messages 5 2 U Unit Accessories See Accessories User Access Door 3 2 Battery Replacement 5 4 EPROM Installation 5 4 V Vibration Resistance 3 3 W Weight 1 3 Wiring 4 1 Cautions 4 2 General Wiring 4 2 Power Supply 4...

Page 35: ...MEMO Graphic FX 50DU TK S C Units Index 6 6 4 ...

Page 36: ...NITS MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE MITSUBISHI DENKI BLDG MARUNOUCHI TOKYO 100 TELEX J24532 CABLE TOKYO HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN JY992D64301A Effective JAN 1997 Specifications are subject to change without notice ...

Reviews: