33
6.1 Contact input signals
6. Functions of Input/Output Signals
4) Manual output 1/ Manual output 2 selection signal
• Signals to switch the manual output to manual output 1 or manual output 2.
• When these signals are OFF, the manual output 1 will be selected.
• During automatic control, when the manual output signal 1 or 2 is turned ON, the control output will
be fixed to manual output 1 or 2.
• During automatic control, when these signals are turned OFF, automatic control will be started using
the output obtained when turning OFF the signal.
• At starting the machine, by using manual output signal 1 and [RUN] input signal as shown in the
following sequence diagram, the control output can be fixed during acceleration, and change in the
tension can be reduced during acceleration at starting the machine. - - - - - - - - Refer to Sec. 5.1.1.
Goes out
Goes out
ON
OFF
ON
OFF
MANUAL indicator
LED(10)
Stop timer
Manual setting 1
Manual output 1
signal
Manual output 2
signal
AUTO indicator
LED(11)
[RUN] signal
Control output
Manual
setting 2
Manual setting 1
Automatic control
Lights
Flashes
Lights
Lights
Flashes
Goes out
Goes out
Goes out
Goes out
Line speed
[RUN] signal
AUTO indicator
LED(11)
Operation speed
Control output
Manual setting 1
Manual output 1
signal
MANUAL indicator
LED(10)
Lights
Flashes
Goes out
Flashes
Summary of Contents for LE-30CTN