background image

This manual confers no industrial property rights or any rights of any other kind, 
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be 
held responsible for any problems involving industrial property rights which may 
occur as a result of using the contents noted in this manual.

Warranty

Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:
(1) Damages caused by any cause found not to be the responsibility of Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.
(3) Special damages and secondary damages whether foreseeable or not, compensation for 

accidents, and compensation for damages to products other than Mitsubishi products.

(4) Replacement by the user, maintenance of on-site equipment, start-up test run 

and other tasks.

For safe use

This product has been manufactured as a general-purpose part for general 
industries, and has not been designed or manufactured to be incorporated in 
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric 
power, aerospace, medicine or passenger movement vehicles, consult with 
Mitsubishi Electric.
This product has been manufactured under strict quality control. However 
when installing the product where major accidents or losses could occur if the 
product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE  : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

Side

A

Side

B

JAPANESE

ENGLISH

JY997D43401E

Side

B

Safety Precautions

 

(Read these precautions before use.)

This manual classifies the safety precautions into two categories:

 and 

.

Depending on the circumstances, procedures indicated by 

 may also

cause severe injury.
It is important to follow all precautions for personal safety.

Associated Manuals

Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.

Manual name

Manual No.

Description

FX

3U

-16CCL-M

User's Manual

JY997D43601

MODEL CODE: 

09R724

Describes details of the FX

3U

-

16CCL-M CC-Link master block.

FX

3G

 Series 

User’s Manual 
- Hardware Edition

JY997D31301

MODEL CODE: 

09R521

Explains the FX

3G

 Series PLC

specifications for I/O, wiring,
installation, and maintenance.

FX

3GC

 Series 

User’s Manual 
- Hardware Edition

JY997D45401

MODEL CODE: 

09R533

Explains the FX

3GC

 Series PLC

specifications for I/O, wiring,
installation, and maintenance.

FX

3U

 Series 

User’s Manual 
- Hardware Edition

JY997D16501

MODEL CODE: 

09R516

Explains the FX

3U

 Series PLC

specifications for I/O, wiring,
installation, and maintenance.

FX

3UC

 Series 

User’s Manual 
- Hardware Edition

JY997D28701

MODEL CODE: 

09R519

Explains the FX

3UC

 Series PLC

specifications for I/O, wiring,
installation, and maintenance.

FX

3S

/FX

3G

/FX

3GC

/

FX

3U

/FX

3UC

 Series 

Programming Manual 
- Basic & Applied 
Instruction Edition

JY997D16601

MODEL CODE: 

09R517

Describes PLC programming for 
basic/applied instructions and 
devices.

MELSEC iQ-F FX5U 
User’s Manual 
(Hardware)

JY997D55301

MODEL CODE:

09R536

Explains the FX5U PLC 
specifications for I/O, wiring, 
installation, and maintenance.

MELSEC iQ-F FX5UC
User’s Manual 
(Hardware)

JY997D61401

MODEL CODE:

09R558

Explains the FX5UC PLC 
specifications for I/O, wiring, 
installation, and maintenance.

How to obtain manuals

For product manuals or documents, consult with the Mitsubishi Electric dealer from
who you purchased your product.

Certification of UL, cUL standards

FX

3U

-16CCL-M units comply with the UL standards (UL, cUL).

UL, cUL File Number:E95239
Regarding the standards that comply with the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.

Compliance with EC directive (CE Marking)

This note does not guarantee that an entire mechanical module produced in
accordance with the contents of this note will comply with the following standards.
Compliance to EMC directive and LVD directive for the entire mechanical module
should be checked by the user / manufacturer. For more information please consult
with your nearest Mitsubishi product provider.
Regarding the standards that comply with the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.

Requirement for Compliance with EMC directive

The following products have shown compliance through direct testing (of the identified
standards below) and design analysis (through the creation of a technical construction
file) to the European Directive for Electromagnetic Compatibility (2014/30/EU) when
used as directed by the appropriate documentation.

Attention

This product is designed for use in industrial applications.

Type:

Programmable Controller (Open Type Equipment)

Models:

MELSEC FX

3U

 series manufactured

from August 1st, 2011

FX

3U

-16CCL-M

Caution for EC Directive

Installation in Enclosure
Programmable controllers are open-type devices that must be installed and used
within conductive control cabinets. Please use the programmable controller while
installed within a conductive shielded control cabinet. Please secure the cabinet
door to the control cabinet (for conduction). Installation within a control cabinet
greatly affects the safety of the system and aids in shielding noise from the
programmable controller.

Control cabinet

- The control cabinet must be conductive.
- Ground the control cabinet with the thickest possible grounding cable.
- To ensure that there is electric contact between the control cabinet and its door, 

connect the cabinet and its doors with thick wires. 

- In order to suppress the leakage of radio waves, the control cabinet structure 

must have minimal openings. Also, wrap the cable holes with a shielding cover 
or other shielding devices.

- The gap between the control cabinet and its door must be as small as possible 

by attaching EMI gaskets between them.

*1 These wires are used to improve the conductivity between the door and control

cabinet.

Standard

Remark

EN61131-2:2007
Programmable controllers

- Equipment requirements

and tests

Compliance with all relevant aspects of the
standard.
EMI
• Radiated Emission
• Conducted Emission
EMS
• Radiated electromagnetic field
• Fast transient burst
• Electrostatic discharge
• High-energy surge
• Voltage drops and interruptions

• Conducted RF
• Power frequency magnetic field

Shielding cover

Shielded cable

Wires

*1

EMI gasket

Configuration example inside control cabinet

Wiring simplified diagram

Notes for compliance with EN61131-2:2007
General notes on the use of the power supply cable.

- The FX

3U

-16CCL-M unit requires that the cable used for power supply is 30 m or 

less.

- When the cable used for power supply exceeds 30 m, a noise filter (Ex. TDK-

Lambda MBS1205-22 or similar) should be placed on the 24 V DC power cabling 
as close (within 500 mm) to the FX

3U

-16CCL-M termination points as possible, 

refer to following figure.

1. Introduction

The CC-Link master block FX

3U

-16CCL-M is a special function block which assigns an

FX

3G

/FX

3GC

/FX

3U

/FX

3UC

/FX5U/FX5UC PLC as the master station of a CC-Link system.

Only one FX

3U-

16CCL-M unit can be connected to a single programmable controller

main unit.

→ 

For details, refer to the FX

3U

-16CCL-M User's Manual.

1.1 Major Features of the FX

3U

-16CCL-M

1) Compatible with CC-Link Ver. 2.00 and Ver. 1.10

The FX

3U-

16CCL-M is compatible with CC-Link Ver. 2.00, and enables expanded

cyclic transmission to facilitate the handling of applications requiring multiple
points of data processing.
In addition to Ver. 2.00, Ver. 1.10 is also supported by the FX

3U-

16CCL-M.

2) The FX

3U-

16CCL-M supports connection of intelligent device stations

Remote I/O stations, remote device stations and intelligent device station can also
be connected to the FX

3U-

16CCL-M.

[Caution]

Local stations can not be connected.

1.2 Incorporated Items

Check to ensure the following product and items are included in the package.

Included Item

FX

3U

-16CCL-M

1 unit

Special unit/block No. label

1 sheet

Te r m i n a l
resistor

For CC-Link dedicated cable
110 

Ω

 1/2 W (color cable: brown, brown and brown)

2 cables

For CC-Link dedicated high-performance cable
130 

Ω

 1/2 W (color cable: brown, orange and brown)

2 cables

Dust proof protection sheet

1 sheet

Manuals (Japanese version, English version)

1 manual each

Main unit

Conductive control cabinet

CC-Link dedicated cable

24+ 24-

DA DB

SLD

DG

L N

Power
cable

24V DC power

supply

Ground
cable

Cable clamp
(AD75CK, 
MITSUBISHI)

Ground
cable

FX

3U

-16CCL-M

DA

DB

DG

SLD

DA

DB

DG

SLD

FG

DA

DB

DG

SLD

FG

(Blue)

(White)

(Yellow)

Termi-
nating
resistor

Termi-
nating
resistor

Other
station

Other
station

FX

3U

-16CCL-M

CC-Link
Dedicated
Cable

CC-Link
Dedicated
Cable

Exceeding 30 m

24 V DC

500 mm or less

Noise

Filter

24 V DC power

supply

FX

3U

-16CCL-M

1.3 External Dimensions and Part Names

1.4 Power and status LEDs

1.5 Terminal Layout

[1] Extension cable

[7]

DIN rail mounting hook

[2] Direct mounting hole

2 holes of 

φ

4.5 (0.18") 

(mounting screw: M4 screw)

[8]

Power supply terminal block

[3] Power LED (green)

[9]

Extension connector

[4] Status LEDs

[10] CC-Link connection terminal block

[5] Name plate

[11] Transmission rate setting switch

[6] DIN rail mounting groove 

(DIN rail: DIN46277, 
35 mm (1.38") width)

[12] Station number setting switch

LED

display

LED

Color

Status

Description

POWER Green

OFF

Power is not being supplied from the external
power supply (24 V DC).

ON

Power is being supplied from the external power
supply (24 V DC).

RUN

Green

OFF

FX

3U

-16CCL-M has failed.

ON

Under FX

3U

-16CCL-M normal operation.

ERR.

Red

OFF

No errors.

Flicker

Communication error has occurred in some
stations.

ON

Communication error has occurred in all stations,
error in the settings, error in the parameter details,

error with the communication, error with the H/W.

L RUN

Green

OFF

Offline.

ON

Data link is being executed (host station).

L ERR.

Red

OFF

No communication error.

Flicker

The switch setting was changed after start.
There is no terminating resistor.
Influence from noise.

ON

There is a data linking error (host station).
There is a setting error.

SD

Green

OFF

Data is not being sent.

ON

Data is being sent.

RD

Green

OFF

Data is not being received.

ON

Data is being received.

Without top cover

2-

φ

4.5 mounting holes

[1]

[3]

[2]

[4]

[5]

[9]

[8]

[11]

[12]

[6]

[7]

87 (3.43")

55 (2.17")

90 (3.55")

Unit: mm (inches)
MASS (Weight): Approx. 0.3 kg (0.66 lbs)

9 (0.36")

4 (0.16")

80 (3.15")

(mounting hole pitch)

[10]

24+

24-

DA

DB

SL
D

DG

Power supply

terminal block

CC-Link connection

terminal block

Terminal screw and terminal block mounting screw size, and tightening torque
Power supply terminal block, CC-Link connection terminal block: 

M3 screw, 0.42 to 0.58 N

m

CC-Link connection terminal block mounting screw (black): 

M3.5 screw, 0.66 to 0.91 N

m

Do not tighten the terminal block mounting screws with a torque outside the
above-mentioned range.
Failure to do so may cause equipment failures or malfunctions.
CC-Link connection terminal block can be detached or attached. Make sure to cut
off all phases of the power supply externally.
For details on the wiring and the types of connection cables needed to connect to
the terminal blocks shown in the figure above, refer to the following manual.

→ 

Refer to the FX

3U

-16CCL-M User's Manual.

1.6 Switch setting

With regard to the switch setting for station number, transmission rate, line test,
hardware test, the switch settings become valid after FX

3U

-16CCL-M startup.

If the switch settings are changed after FX

3U

-16CCL-M startup, the L ERR. LED

will flicker.
To change the switch setting, power OFF the FX

3U

-16CCL-M once, and power it

ON again.
For details on the switch setting, refer to the following manual.

→ 

Refer to the FX

3U

-16CCL-M User's Manual.

1.6.1

Station number setting

1.6.2

Transmission rate setting, line test, hardware test

2. Installation

For details on installation, refer to the following manual.

→ 

Refer to the FX

3U

-16CCL-M User's Manual.

Setting items

Range

Description

× 

10

0,1

Online: 0 (Master station)

Line test: 0 to 16

17 to 99 is the setting error.

× 

1

0 to 9

Setting

Description

Status

0

Transmission rate 156 Kbps

Online

1

Transmission rate 625 Kbps

2

Transmission rate 2.5 Mbps

3

Transmission rate 5 Mbps

4

Transmission rate 10 Mbps

5

Transmission rate 156 Kbps

Line test

When the station number

setting switch is 0:

Line test 1

When the station number

setting switch is 1 to 16:

Line test 2

6

Transmission rate 625 Kbps

7

Transmission rate 2.5 Mbps

8

Transmission rate 5 Mbps

9

Transmission rate 10 Mbps

A

Transmission rate 156 Kbps

Hardware test

B

Transmission rate 625 Kbps

C

Transmission rate 2.5 Mbps

D

Transmission rate 5 Mbps

E

Transmission rate 10 Mbps

F

Unusable

Unusable

INSTALLATION 
PRECAUTIONS

Make sure to cut off all phases of the power supply externally before attempting installation
work. Failure to do so may cause electric shock or damage to the product.

INSTALLATION 
PRECAUTIONS

Use the product within the generic environment specifications described in PLC main unit
manual (Hardware Edition). 
Never use the product in areas with excessive dust, oily smoke, conductive dusts, corrosive
gas (salt air, Cl

2

, H

2

S

,

 SO

2

 or NO

2

), flammable gas, vibration or impacts, or expose it to high

temperature, condensation, or rain and wind. If the product is used in such conditions, electric
shock, fire, malfunctions, deterioration or damage may occur.

Do not touch the conductive parts of the product directly. 
Doing so may cause device failures or malfunctions.

Install the product securely using a DIN rail or mounting screws.

Install the product on a flat surface. If the mounting surface is rough, undue force will be applied
to the PC board, thereby causing nonconformities.

When drilling screw holes or wiring, make sure or cutting or wire debris does not enter the
ventilation slits. Failure to do so may cause fire, equipment failures or malfunctions.

Be sure to remove the dust proof sheet from the PLC's ventilation slits when installation work is
completed. 
 Failure to do so may cause fire, equipment failures or malfunctions.

Make sure to attach the top cover, offered as an accessory, before turning on the power or
initiating operation after installation or wiring work. Failure to do so may cause electric shock.

Connect extension cables securely to their designated connectors. Loose connections may
cause malfunctions.

2.1 Connection with PLC

Only one FX

3U

-16CCL-M can be connected to the right side of a PLC main unit or

extension unit/block (including special function units/blocks).
For connection to an FX

3GC

/FX

3UC

 Series PLC or FX

2NC

 Series extension block, an

FX

2NC

-CNV-IF or FX

3UC

-1PS-5V is required. 

For connection to FX5U/FX5UC PLC, FX5-CNV-BUS or FX5-CNV-BUSC is required.
For details, refer to the respective PLC manual.

→ 

Refer to the FX

3G

 Series User's Manual - Hardware Edition.

→ 

Refer to the FX

3GC

 Series User's Manual - Hardware Edition.

→ 

Refer to the FX

3U

 Series User's Manual - Hardware Edition.

→ 

Refer to the FX

3UC

 Series User's Manual - Hardware Edition.

→ 

Refer to the MELSEC iQ-F FX5U User's Manual (Hardware).

→ 

Refer to the MELSEC iQ-F FX5UC User's Manual (Hardware).

2.2 Mounting

The product is mounted by the following method.

DIN rail mounting

Direct mounting (mounting screw: M4 screw)

For details, refer to the respective PLC manual.

→ 

Refer to the FX

3G

 Series User's Manual - Hardware Edition.

→ 

Refer to the FX

3GC

 Series User's Manual - Hardware Edition.

→ 

Refer to the FX

3U

 Series User's Manual - Hardware Edition.

→ 

Refer to the FX

3UC

 Series User's Manual - Hardware Edition.

→ 

Refer to the MELSEC iQ-F FX5U User's Manual (Hardware).

→ 

Refer to the MELSEC iQ-F FX5UC User's Manual (Hardware).

3. Specification

For details on specifications, refer to the following manual.

→ 

Refer to the FX

3U

-16CCL-M User's Manual.

3.1 Applicable PLC

DESIGN
PRECAUTIONS

When executing control (data changes) to an operating PLC, construct an interlock circuit in the
sequence program so that the entire system operates conservatively. 
Additionally, when executing control such as program changes and operation status changes (status
control) to an operating PLC, thoroughly read the manual and sufficiently confirm safety in advance. 
Especially in control from external equipment to a PLC in a remote place, problems in the PLC may
not be able to be handled promptly due to abnormality in data transfer. Construct an interlock circuit
in the sequence program. At the same time, determine the actions in the system between the
external equipment and the PLC for protection against abnormalities in data transfer.

Make sure to have the following safety circuits outside the PLC to ensure safe system operation even
during external power supply problems or PLC failure. Otherwise, malfunctions may cause serious
accidents.
1) Most importantly, have the following: an emergency stop circuit, a protection circuit, an interlock

circuit for opposite movements (such as normal vs. reverse rotation), and an interlock circuit (to
prevent damage to the equipment at the upper and lower positioning limits).

2) Note that when the PLC CPU detects an error, such as a watchdog timer error, during self-

diagnosis, all outputs are turned off. Also, when an error that cannot be detected by the PLC
CPU occurs in an input/output control block, output control may be disabled.
External circuits and mechanisms should be designed to ensure safe machinery operation in
such a case.

DESIGN
PRECAUTIONS

Make sure to observe the following precautions in order to prevent any damage to the machinery or
accidents due to abnormal data written to the PLC under the influence of noise:
1) Do not bundle the control line together with or lay it close to the main circuit or power line. As a

guideline, lay the control line at least 100 mm (3.94") or more away from the main circuit or
power line. Noise may cause malfunctions.

2) Ground the shield wire or shield of a shielded cable. Do not use common grounding with heavy

electrical systems.

Install module so that excessive force will not be applied to the power supply terminal block or CC-
Link connection terminal block.
Failure to do so may result in wire damage/breakage or PLC failure.

DISPOSAL
PRECAUTIONS

Please contact a certified electronic waste disposal company for the environmentally safe recycling
and disposal of your device.

TRANSPORTATION AND 
STORAGE PRECAUTIONS

The PLC is a precision instrument. During transportation, avoid impacts larger than those specified in
the general specifications of the PLC main unit manual by using dedicated packaging boxes and
shock-absorbing palettes. Failure to do so may cause failures in the PLC. 
After transportation, verify operation of the PLC and check for damage of the mounting part, etc.

Model name

Applicability

FX

3G

 Series PLC

Ver. 1.00 and later

*3

Only one FX

3U-

16CCL-M unit can be connected in a main unit.

FX

3GC

 Series PLC

Ver. 1.40 and later

*3

Only one FX

3U-

16CCL-M unit can be connected in a main unit.

FX

3U

 Series PLC

Ver. 2.20 and later

*3

Only one FX

3U-

16CCL-M unit can be connected in a main unit.

FX

3UC

 Series PLC

*1

Ver. 2.20 and later

*3

Only one FX

3U-

16CCL-M unit can be connected in a main unit.

FX5U PLC

*2

From first production
Only one FX

3U-

16CCL-M unit can be connected in a CPU module.

FX5UC PLC

*2

From first production
Only one FX

3U-

16CCL-M unit can be connected in a CPU module.

*1 An FX

2NC

-CNV-IF or FX

3UC

-1PS-5V is necessary to connect the FX

3U-

16CCL-

M with the FX

3GC

/FX

3UC

 PLC.

*2 An FX5-CNV-BUS or FX5-CNV-BUSC is necessary to connect the FX

3U-

16CCL-

M with the FX5U/FX5UC PLC.

*3 The version number can be checked by reading the last three digits of device

D8001/D8101.

3.2 General Specifications

Items other than the following are equivalent to those of the PLC main unit.
For general specifications, refer to the manual of the PLC main unit.

→ 

Refer to the FX

3G

 Series User's Manual - Hardware Edition.

→ 

Refer to the FX

3GC

 Series User's Manual - Hardware Edition.

→ 

Refer to the FX

3U

 Series User's Manual - Hardware Edition.

→ 

Refer to the FX

3UC

 Series User's Manual - Hardware Edition.

→ 

Refer to the MELSEC iQ-F FX5U User's Manual (Hardware).

→ 

Refer to the MELSEC iQ-F FX5UC User's Manual (Hardware).

3.3 Power Supply Specification

3.4 Performance Specification

Item

Specification

Dielectric withstand 
voltage

500 V AC for one minute

Between all terminals and ground
terminal

Insulation 
resistance

5 M

Ω

 or higher by 500 V

DC insulation resistance
tester

Item

Specification

External power 
supply

Power supply 
voltage

24 V DC +20% -15% 
Ripple (p-p) within 5%

Permitted 
instantaneous power 
failure time

O p e r a t i o n   c o n t i n u e s   w h e n   t h e
instantaneous power failure is shorter than
PS1:1 ms.

Current consumption

240mA

Internal power 
supply

Power supply voltage

5 V DC of PLC is not used. (5 V DC is
converted from 24 V DC external power
supply.)
Make sure to observe the power-on timing
and the procedure.

Current consumption

Item

Specification

Applicable function

Master station function (The local station and standby
master station functions are not provided.)

CC-Link applicable version

Ver. 2.00 (Ver. 1.10 also supported.)

Station number

0 (set by rotary switch)

Transmission rate

156 Kbps/625 Kbps/2.5 Mbps/5 Mbps/10 Mbps
 (set by rotary switch)

Maximum total cable length
(maximum transmission
distance)

1 , 2 0 0   m   m a x i m u m   ( v a r i e s   d e p e n d i n g   o n   t h e
transmission speed.)
For details, refer to the FX

3U

-16CCL-M User's Manual.

Connection cable

*1

CC-Link dedicated cable/ 
CC-Link dedicated high-performance cable/ 
Ver. 1.10 compatible CC-Link dedicated cable

M a x i m u m   n u m b e r   o f
connectable stations

1) Remote I/O stations: 8 maximum

(Each stations occupies 32 I/O points of the PLC.)

2) Remote device st Intelligent device

stations: 8 maximum
(The total number of RX/RY points is 256 or less.)

Maximum number of I/O
points per system

When using an FX

3U

/FX

3UC

/FX5U/FX5UC PLC

1) + 2) total number of points 

 384 points

1) (Actual number of PLC I/O points) + (Number of

points occupied by special function blocks) +
(Number of points occupied by the FX

3U

-16CCL-

M: 8 points) 

 256 points

2) 32 

× 

Number of remote I/O stations 

≤ 

256 points

When using an FX

3G

/FX

3GC

 

PLC

32 

× 

Number of remote I/O stations 

≤ 

128 points

Number of link points per
station

*2

Remote I/O (RX, RY): 32 points
Remote register (RWw): 
4 points (Master station 

 Remote device station/

intelligent device station)
Remote register (RWr): 
4 points (Remote device station/intelligent device
station) 

 Master station)

Communication with PLC

*3

By FROM and TO instructions or direct specification of
buffer memory (FX

3U

/FX

3UC

) via the buffer memory.

Number of I/O occupied
points

8 points

Number of connectable
units to the main unit

1 (An FX

3U

-16CCL-M cannot be attached to main unit

with an FX

2N

-16CCL-M.)

*1 CC-Link dedicated cables, Ver. 1.10 compatible CC-Link dedicated cable

and CC-Link dedicated high-performance cable cannot be used together.
Also attach the terminating resister which matches the kind of the cable.

*2 Indicates the number of link points for remote net ver. 1 mode. For the

number of link points for remote net ver. 2 mode/remote net additional
mode, refer to the FX

3U

-16CCL-M User's Manual.

*3 For details of other applied instructions and methods, refer to the FX

3S

/

FX

3G

/FX

3GC

/FX

3U

/FX

3UC

 Programming Manual.

Note: This symbol mark is for China only.

含有有害6物质的名称,含有量,含有部品

 本产品中所含有的有害6 物质的名称,含有量,含有部品如下表

所示。

产品中有害物质的名称及含量

本表格依据SJ/T 11364的规定编制。

○:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572

 规定的限量要求以下。 

×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T 
    26572规定的限量要求。

部件名称

有害物质

(Pb)

(Hg)

(Cd)

六价铬

(Cr(VI))

多溴联苯

(PBB)

多溴

二苯醚
(PBDE)

可编程
控制器

外壳

印刷基板

×

「电器电子产品有害物质限制使用标识要求」的表示方式

基于中国标准法的参考规格:GB/T15969.2

FX

3U

-16CCL-M

INSTALLATION MANUAL

This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and the manuals of all relevant
products fully to acquire proficiency in handling and operating the product. Make
sure to learn all the product information, safety information, and precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration:
The company and product names described in this manual are registered
trademarks or the trademarks of their respective companies.

Effective May 2018
Specifications are subject to change without notice.

©

 2011 Mitsubishi Electric Corporation

Manual Number JY997D43401

Revision

E

Date

May 2018

Reviews: