This manual confers no industrial property rights or any rights of any other kind,
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be
held responsible for any problems involving industrial property rights which may
occur as a result of using the contents noted in this manual.
Warranty
Exclusion of loss in opportunity and secondary loss from warranty liability
Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to:
(1) Damages caused by any cause found not to be the responsibility of Mitsubishi.
(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products.
(3) Special damages and secondary damages whether foreseeable or not, compensation for
accidents, and compensation for damages to products other than Mitsubishi products.
(4) Replacement by the user, maintenance of on-site equipment, start-up test run
and other tasks.
For safe use
This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
This product has been manufactured under strict quality control. However
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.
•
•
•
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
Side
A
Side
B
JAPANESE
ENGLISH
JY997D43401E
Side
B
Safety Precautions
(Read these precautions before use.)
This manual classifies the safety precautions into two categories:
and
.
Depending on the circumstances, procedures indicated by
may also
cause severe injury.
It is important to follow all precautions for personal safety.
Associated Manuals
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Manual name
Manual No.
Description
FX
3U
-16CCL-M
User's Manual
JY997D43601
MODEL CODE:
09R724
Describes details of the FX
3U
-
16CCL-M CC-Link master block.
FX
3G
Series
User’s Manual
- Hardware Edition
JY997D31301
MODEL CODE:
09R521
Explains the FX
3G
Series PLC
specifications for I/O, wiring,
installation, and maintenance.
FX
3GC
Series
User’s Manual
- Hardware Edition
JY997D45401
MODEL CODE:
09R533
Explains the FX
3GC
Series PLC
specifications for I/O, wiring,
installation, and maintenance.
FX
3U
Series
User’s Manual
- Hardware Edition
JY997D16501
MODEL CODE:
09R516
Explains the FX
3U
Series PLC
specifications for I/O, wiring,
installation, and maintenance.
FX
3UC
Series
User’s Manual
- Hardware Edition
JY997D28701
MODEL CODE:
09R519
Explains the FX
3UC
Series PLC
specifications for I/O, wiring,
installation, and maintenance.
FX
3S
/FX
3G
/FX
3GC
/
FX
3U
/FX
3UC
Series
Programming Manual
- Basic & Applied
Instruction Edition
JY997D16601
MODEL CODE:
09R517
Describes PLC programming for
basic/applied instructions and
devices.
MELSEC iQ-F FX5U
User’s Manual
(Hardware)
JY997D55301
MODEL CODE:
09R536
Explains the FX5U PLC
specifications for I/O, wiring,
installation, and maintenance.
MELSEC iQ-F FX5UC
User’s Manual
(Hardware)
JY997D61401
MODEL CODE:
09R558
Explains the FX5UC PLC
specifications for I/O, wiring,
installation, and maintenance.
How to obtain manuals
For product manuals or documents, consult with the Mitsubishi Electric dealer from
who you purchased your product.
Certification of UL, cUL standards
FX
3U
-16CCL-M units comply with the UL standards (UL, cUL).
UL, cUL File Number:E95239
Regarding the standards that comply with the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.
Compliance with EC directive (CE Marking)
This note does not guarantee that an entire mechanical module produced in
accordance with the contents of this note will comply with the following standards.
Compliance to EMC directive and LVD directive for the entire mechanical module
should be checked by the user / manufacturer. For more information please consult
with your nearest Mitsubishi product provider.
Regarding the standards that comply with the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.
Requirement for Compliance with EMC directive
The following products have shown compliance through direct testing (of the identified
standards below) and design analysis (through the creation of a technical construction
file) to the European Directive for Electromagnetic Compatibility (2014/30/EU) when
used as directed by the appropriate documentation.
Attention
This product is designed for use in industrial applications.
Type:
Programmable Controller (Open Type Equipment)
Models:
MELSEC FX
3U
series manufactured
from August 1st, 2011
FX
3U
-16CCL-M
Caution for EC Directive
•
Installation in Enclosure
Programmable controllers are open-type devices that must be installed and used
within conductive control cabinets. Please use the programmable controller while
installed within a conductive shielded control cabinet. Please secure the cabinet
door to the control cabinet (for conduction). Installation within a control cabinet
greatly affects the safety of the system and aids in shielding noise from the
programmable controller.
•
Control cabinet
- The control cabinet must be conductive.
- Ground the control cabinet with the thickest possible grounding cable.
- To ensure that there is electric contact between the control cabinet and its door,
connect the cabinet and its doors with thick wires.
- In order to suppress the leakage of radio waves, the control cabinet structure
must have minimal openings. Also, wrap the cable holes with a shielding cover
or other shielding devices.
- The gap between the control cabinet and its door must be as small as possible
by attaching EMI gaskets between them.
*1 These wires are used to improve the conductivity between the door and control
cabinet.
Standard
Remark
EN61131-2:2007
Programmable controllers
- Equipment requirements
and tests
Compliance with all relevant aspects of the
standard.
EMI
• Radiated Emission
• Conducted Emission
EMS
• Radiated electromagnetic field
• Fast transient burst
• Electrostatic discharge
• High-energy surge
• Voltage drops and interruptions
• Conducted RF
• Power frequency magnetic field
Shielding cover
Shielded cable
Wires
*1
EMI gasket
•
Configuration example inside control cabinet
•
Wiring simplified diagram
•
Notes for compliance with EN61131-2:2007
General notes on the use of the power supply cable.
- The FX
3U
-16CCL-M unit requires that the cable used for power supply is 30 m or
less.
- When the cable used for power supply exceeds 30 m, a noise filter (Ex. TDK-
Lambda MBS1205-22 or similar) should be placed on the 24 V DC power cabling
as close (within 500 mm) to the FX
3U
-16CCL-M termination points as possible,
refer to following figure.
1. Introduction
The CC-Link master block FX
3U
-16CCL-M is a special function block which assigns an
FX
3G
/FX
3GC
/FX
3U
/FX
3UC
/FX5U/FX5UC PLC as the master station of a CC-Link system.
Only one FX
3U-
16CCL-M unit can be connected to a single programmable controller
main unit.
→
For details, refer to the FX
3U
-16CCL-M User's Manual.
1.1 Major Features of the FX
3U
-16CCL-M
1) Compatible with CC-Link Ver. 2.00 and Ver. 1.10
The FX
3U-
16CCL-M is compatible with CC-Link Ver. 2.00, and enables expanded
cyclic transmission to facilitate the handling of applications requiring multiple
points of data processing.
In addition to Ver. 2.00, Ver. 1.10 is also supported by the FX
3U-
16CCL-M.
2) The FX
3U-
16CCL-M supports connection of intelligent device stations
Remote I/O stations, remote device stations and intelligent device station can also
be connected to the FX
3U-
16CCL-M.
[Caution]
Local stations can not be connected.
1.2 Incorporated Items
Check to ensure the following product and items are included in the package.
Included Item
FX
3U
-16CCL-M
1 unit
Special unit/block No. label
1 sheet
Te r m i n a l
resistor
For CC-Link dedicated cable
110
Ω
1/2 W (color cable: brown, brown and brown)
2 cables
For CC-Link dedicated high-performance cable
130
Ω
1/2 W (color cable: brown, orange and brown)
2 cables
Dust proof protection sheet
1 sheet
Manuals (Japanese version, English version)
1 manual each
Main unit
Conductive control cabinet
CC-Link dedicated cable
24+ 24-
DA DB
SLD
DG
L N
Power
cable
24V DC power
supply
Ground
cable
Cable clamp
(AD75CK,
MITSUBISHI)
Ground
cable
FX
3U
-16CCL-M
DA
DB
DG
SLD
DA
DB
DG
SLD
FG
DA
DB
DG
SLD
FG
(Blue)
(White)
(Yellow)
Termi-
nating
resistor
Termi-
nating
resistor
Other
station
Other
station
FX
3U
-16CCL-M
CC-Link
Dedicated
Cable
CC-Link
Dedicated
Cable
Exceeding 30 m
24 V DC
500 mm or less
Noise
Filter
24 V DC power
supply
FX
3U
-16CCL-M
1.3 External Dimensions and Part Names
1.4 Power and status LEDs
1.5 Terminal Layout
[1] Extension cable
[7]
DIN rail mounting hook
[2] Direct mounting hole
2 holes of
φ
4.5 (0.18")
(mounting screw: M4 screw)
[8]
Power supply terminal block
[3] Power LED (green)
[9]
Extension connector
[4] Status LEDs
[10] CC-Link connection terminal block
[5] Name plate
[11] Transmission rate setting switch
[6] DIN rail mounting groove
(DIN rail: DIN46277,
35 mm (1.38") width)
[12] Station number setting switch
LED
display
LED
Color
Status
Description
POWER Green
OFF
Power is not being supplied from the external
power supply (24 V DC).
ON
Power is being supplied from the external power
supply (24 V DC).
RUN
Green
OFF
FX
3U
-16CCL-M has failed.
ON
Under FX
3U
-16CCL-M normal operation.
ERR.
Red
OFF
No errors.
Flicker
Communication error has occurred in some
stations.
ON
Communication error has occurred in all stations,
error in the settings, error in the parameter details,
error with the communication, error with the H/W.
L RUN
Green
OFF
Offline.
ON
Data link is being executed (host station).
L ERR.
Red
OFF
No communication error.
Flicker
The switch setting was changed after start.
There is no terminating resistor.
Influence from noise.
ON
There is a data linking error (host station).
There is a setting error.
SD
Green
OFF
Data is not being sent.
ON
Data is being sent.
RD
Green
OFF
Data is not being received.
ON
Data is being received.
Without top cover
2-
φ
4.5 mounting holes
[1]
[3]
[2]
[4]
[5]
[9]
[8]
[11]
[12]
[6]
[7]
87 (3.43")
55 (2.17")
90 (3.55")
Unit: mm (inches)
MASS (Weight): Approx. 0.3 kg (0.66 lbs)
9 (0.36")
4 (0.16")
80 (3.15")
(mounting hole pitch)
[10]
24+
24-
DA
DB
SL
D
DG
Power supply
terminal block
CC-Link connection
terminal block
•
Terminal screw and terminal block mounting screw size, and tightening torque
Power supply terminal block, CC-Link connection terminal block:
M3 screw, 0.42 to 0.58 N
•
m
CC-Link connection terminal block mounting screw (black):
M3.5 screw, 0.66 to 0.91 N
•
m
Do not tighten the terminal block mounting screws with a torque outside the
above-mentioned range.
Failure to do so may cause equipment failures or malfunctions.
CC-Link connection terminal block can be detached or attached. Make sure to cut
off all phases of the power supply externally.
For details on the wiring and the types of connection cables needed to connect to
the terminal blocks shown in the figure above, refer to the following manual.
→
Refer to the FX
3U
-16CCL-M User's Manual.
1.6 Switch setting
With regard to the switch setting for station number, transmission rate, line test,
hardware test, the switch settings become valid after FX
3U
-16CCL-M startup.
If the switch settings are changed after FX
3U
-16CCL-M startup, the L ERR. LED
will flicker.
To change the switch setting, power OFF the FX
3U
-16CCL-M once, and power it
ON again.
For details on the switch setting, refer to the following manual.
→
Refer to the FX
3U
-16CCL-M User's Manual.
1.6.1
Station number setting
1.6.2
Transmission rate setting, line test, hardware test
2. Installation
For details on installation, refer to the following manual.
→
Refer to the FX
3U
-16CCL-M User's Manual.
Setting items
Range
Description
×
10
0,1
Online: 0 (Master station)
Line test: 0 to 16
17 to 99 is the setting error.
×
1
0 to 9
Setting
Description
Status
0
Transmission rate 156 Kbps
Online
1
Transmission rate 625 Kbps
2
Transmission rate 2.5 Mbps
3
Transmission rate 5 Mbps
4
Transmission rate 10 Mbps
5
Transmission rate 156 Kbps
Line test
•
When the station number
setting switch is 0:
Line test 1
•
When the station number
setting switch is 1 to 16:
Line test 2
6
Transmission rate 625 Kbps
7
Transmission rate 2.5 Mbps
8
Transmission rate 5 Mbps
9
Transmission rate 10 Mbps
A
Transmission rate 156 Kbps
Hardware test
B
Transmission rate 625 Kbps
C
Transmission rate 2.5 Mbps
D
Transmission rate 5 Mbps
E
Transmission rate 10 Mbps
F
Unusable
Unusable
INSTALLATION
PRECAUTIONS
•
Make sure to cut off all phases of the power supply externally before attempting installation
work. Failure to do so may cause electric shock or damage to the product.
INSTALLATION
PRECAUTIONS
•
Use the product within the generic environment specifications described in PLC main unit
manual (Hardware Edition).
Never use the product in areas with excessive dust, oily smoke, conductive dusts, corrosive
gas (salt air, Cl
2
, H
2
S
,
SO
2
or NO
2
), flammable gas, vibration or impacts, or expose it to high
temperature, condensation, or rain and wind. If the product is used in such conditions, electric
shock, fire, malfunctions, deterioration or damage may occur.
•
Do not touch the conductive parts of the product directly.
Doing so may cause device failures or malfunctions.
•
Install the product securely using a DIN rail or mounting screws.
•
Install the product on a flat surface. If the mounting surface is rough, undue force will be applied
to the PC board, thereby causing nonconformities.
•
When drilling screw holes or wiring, make sure or cutting or wire debris does not enter the
ventilation slits. Failure to do so may cause fire, equipment failures or malfunctions.
•
Be sure to remove the dust proof sheet from the PLC's ventilation slits when installation work is
completed.
Failure to do so may cause fire, equipment failures or malfunctions.
•
Make sure to attach the top cover, offered as an accessory, before turning on the power or
initiating operation after installation or wiring work. Failure to do so may cause electric shock.
•
Connect extension cables securely to their designated connectors. Loose connections may
cause malfunctions.
2.1 Connection with PLC
Only one FX
3U
-16CCL-M can be connected to the right side of a PLC main unit or
extension unit/block (including special function units/blocks).
For connection to an FX
3GC
/FX
3UC
Series PLC or FX
2NC
Series extension block, an
FX
2NC
-CNV-IF or FX
3UC
-1PS-5V is required.
For connection to FX5U/FX5UC PLC, FX5-CNV-BUS or FX5-CNV-BUSC is required.
For details, refer to the respective PLC manual.
→
Refer to the FX
3G
Series User's Manual - Hardware Edition.
→
Refer to the FX
3GC
Series User's Manual - Hardware Edition.
→
Refer to the FX
3U
Series User's Manual - Hardware Edition.
→
Refer to the FX
3UC
Series User's Manual - Hardware Edition.
→
Refer to the MELSEC iQ-F FX5U User's Manual (Hardware).
→
Refer to the MELSEC iQ-F FX5UC User's Manual (Hardware).
2.2 Mounting
The product is mounted by the following method.
•
DIN rail mounting
•
Direct mounting (mounting screw: M4 screw)
For details, refer to the respective PLC manual.
→
Refer to the FX
3G
Series User's Manual - Hardware Edition.
→
Refer to the FX
3GC
Series User's Manual - Hardware Edition.
→
Refer to the FX
3U
Series User's Manual - Hardware Edition.
→
Refer to the FX
3UC
Series User's Manual - Hardware Edition.
→
Refer to the MELSEC iQ-F FX5U User's Manual (Hardware).
→
Refer to the MELSEC iQ-F FX5UC User's Manual (Hardware).
3. Specification
For details on specifications, refer to the following manual.
→
Refer to the FX
3U
-16CCL-M User's Manual.
3.1 Applicable PLC
DESIGN
PRECAUTIONS
•
When executing control (data changes) to an operating PLC, construct an interlock circuit in the
sequence program so that the entire system operates conservatively.
Additionally, when executing control such as program changes and operation status changes (status
control) to an operating PLC, thoroughly read the manual and sufficiently confirm safety in advance.
Especially in control from external equipment to a PLC in a remote place, problems in the PLC may
not be able to be handled promptly due to abnormality in data transfer. Construct an interlock circuit
in the sequence program. At the same time, determine the actions in the system between the
external equipment and the PLC for protection against abnormalities in data transfer.
•
Make sure to have the following safety circuits outside the PLC to ensure safe system operation even
during external power supply problems or PLC failure. Otherwise, malfunctions may cause serious
accidents.
1) Most importantly, have the following: an emergency stop circuit, a protection circuit, an interlock
circuit for opposite movements (such as normal vs. reverse rotation), and an interlock circuit (to
prevent damage to the equipment at the upper and lower positioning limits).
2) Note that when the PLC CPU detects an error, such as a watchdog timer error, during self-
diagnosis, all outputs are turned off. Also, when an error that cannot be detected by the PLC
CPU occurs in an input/output control block, output control may be disabled.
External circuits and mechanisms should be designed to ensure safe machinery operation in
such a case.
DESIGN
PRECAUTIONS
•
Make sure to observe the following precautions in order to prevent any damage to the machinery or
accidents due to abnormal data written to the PLC under the influence of noise:
1) Do not bundle the control line together with or lay it close to the main circuit or power line. As a
guideline, lay the control line at least 100 mm (3.94") or more away from the main circuit or
power line. Noise may cause malfunctions.
2) Ground the shield wire or shield of a shielded cable. Do not use common grounding with heavy
electrical systems.
•
Install module so that excessive force will not be applied to the power supply terminal block or CC-
Link connection terminal block.
Failure to do so may result in wire damage/breakage or PLC failure.
DISPOSAL
PRECAUTIONS
•
Please contact a certified electronic waste disposal company for the environmentally safe recycling
and disposal of your device.
TRANSPORTATION AND
STORAGE PRECAUTIONS
•
The PLC is a precision instrument. During transportation, avoid impacts larger than those specified in
the general specifications of the PLC main unit manual by using dedicated packaging boxes and
shock-absorbing palettes. Failure to do so may cause failures in the PLC.
After transportation, verify operation of the PLC and check for damage of the mounting part, etc.
Model name
Applicability
FX
3G
Series PLC
Ver. 1.00 and later
*3
Only one FX
3U-
16CCL-M unit can be connected in a main unit.
FX
3GC
Series PLC
Ver. 1.40 and later
*3
Only one FX
3U-
16CCL-M unit can be connected in a main unit.
FX
3U
Series PLC
Ver. 2.20 and later
*3
Only one FX
3U-
16CCL-M unit can be connected in a main unit.
FX
3UC
Series PLC
*1
Ver. 2.20 and later
*3
Only one FX
3U-
16CCL-M unit can be connected in a main unit.
FX5U PLC
*2
From first production
Only one FX
3U-
16CCL-M unit can be connected in a CPU module.
FX5UC PLC
*2
From first production
Only one FX
3U-
16CCL-M unit can be connected in a CPU module.
*1 An FX
2NC
-CNV-IF or FX
3UC
-1PS-5V is necessary to connect the FX
3U-
16CCL-
M with the FX
3GC
/FX
3UC
PLC.
*2 An FX5-CNV-BUS or FX5-CNV-BUSC is necessary to connect the FX
3U-
16CCL-
M with the FX5U/FX5UC PLC.
*3 The version number can be checked by reading the last three digits of device
D8001/D8101.
3.2 General Specifications
Items other than the following are equivalent to those of the PLC main unit.
For general specifications, refer to the manual of the PLC main unit.
→
Refer to the FX
3G
Series User's Manual - Hardware Edition.
→
Refer to the FX
3GC
Series User's Manual - Hardware Edition.
→
Refer to the FX
3U
Series User's Manual - Hardware Edition.
→
Refer to the FX
3UC
Series User's Manual - Hardware Edition.
→
Refer to the MELSEC iQ-F FX5U User's Manual (Hardware).
→
Refer to the MELSEC iQ-F FX5UC User's Manual (Hardware).
3.3 Power Supply Specification
3.4 Performance Specification
Item
Specification
Dielectric withstand
voltage
500 V AC for one minute
Between all terminals and ground
terminal
Insulation
resistance
5 M
Ω
or higher by 500 V
DC insulation resistance
tester
Item
Specification
External power
supply
Power supply
voltage
24 V DC +20% -15%
Ripple (p-p) within 5%
Permitted
instantaneous power
failure time
O p e r a t i o n c o n t i n u e s w h e n t h e
instantaneous power failure is shorter than
PS1:1 ms.
Current consumption
240mA
Internal power
supply
Power supply voltage
5 V DC of PLC is not used. (5 V DC is
converted from 24 V DC external power
supply.)
Make sure to observe the power-on timing
and the procedure.
Current consumption
Item
Specification
Applicable function
Master station function (The local station and standby
master station functions are not provided.)
CC-Link applicable version
Ver. 2.00 (Ver. 1.10 also supported.)
Station number
0 (set by rotary switch)
Transmission rate
156 Kbps/625 Kbps/2.5 Mbps/5 Mbps/10 Mbps
(set by rotary switch)
Maximum total cable length
(maximum transmission
distance)
1 , 2 0 0 m m a x i m u m ( v a r i e s d e p e n d i n g o n t h e
transmission speed.)
For details, refer to the FX
3U
-16CCL-M User's Manual.
Connection cable
*1
CC-Link dedicated cable/
CC-Link dedicated high-performance cable/
Ver. 1.10 compatible CC-Link dedicated cable
M a x i m u m n u m b e r o f
connectable stations
1) Remote I/O stations: 8 maximum
(Each stations occupies 32 I/O points of the PLC.)
2) Remote device st Intelligent device
stations: 8 maximum
(The total number of RX/RY points is 256 or less.)
Maximum number of I/O
points per system
When using an FX
3U
/FX
3UC
/FX5U/FX5UC PLC
1) + 2) total number of points
≤
384 points
1) (Actual number of PLC I/O points) + (Number of
points occupied by special function blocks) +
(Number of points occupied by the FX
3U
-16CCL-
M: 8 points)
≤
256 points
2) 32
×
Number of remote I/O stations
≤
256 points
When using an FX
3G
/FX
3GC
PLC
32
×
Number of remote I/O stations
≤
128 points
Number of link points per
station
*2
Remote I/O (RX, RY): 32 points
Remote register (RWw):
4 points (Master station
→
Remote device station/
intelligent device station)
Remote register (RWr):
4 points (Remote device station/intelligent device
station)
→
Master station)
Communication with PLC
*3
By FROM and TO instructions or direct specification of
buffer memory (FX
3U
/FX
3UC
) via the buffer memory.
Number of I/O occupied
points
8 points
Number of connectable
units to the main unit
1 (An FX
3U
-16CCL-M cannot be attached to main unit
with an FX
2N
-16CCL-M.)
*1 CC-Link dedicated cables, Ver. 1.10 compatible CC-Link dedicated cable
and CC-Link dedicated high-performance cable cannot be used together.
Also attach the terminating resister which matches the kind of the cable.
*2 Indicates the number of link points for remote net ver. 1 mode. For the
number of link points for remote net ver. 2 mode/remote net additional
mode, refer to the FX
3U
-16CCL-M User's Manual.
*3 For details of other applied instructions and methods, refer to the FX
3S
/
FX
3G
/FX
3GC
/FX
3U
/FX
3UC
Programming Manual.
Note: This symbol mark is for China only.
含有有害6物质的名称,含有量,含有部品
本产品中所含有的有害6 物质的名称,含有量,含有部品如下表
所示。
产品中有害物质的名称及含量
本表格依据SJ/T 11364的规定编制。
○:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572
规定的限量要求以下。
×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T
26572规定的限量要求。
部件名称
有害物质
铅
(Pb)
汞
(Hg)
镉
(Cd)
六价铬
(Cr(VI))
多溴联苯
(PBB)
多溴
二苯醚
(PBDE)
可编程
控制器
外壳
印刷基板
○
○
○
○
○
○
○
○
○
○
○
×
「电器电子产品有害物质限制使用标识要求」的表示方式
基于中国标准法的参考规格:GB/T15969.2
FX
3U
-16CCL-M
INSTALLATION MANUAL
This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and the manuals of all relevant
products fully to acquire proficiency in handling and operating the product. Make
sure to learn all the product information, safety information, and precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration:
The company and product names described in this manual are registered
trademarks or the trademarks of their respective companies.
Effective May 2018
Specifications are subject to change without notice.
©
2011 Mitsubishi Electric Corporation
Manual Number JY997D43401
Revision
E
Date
May 2018