7 Buffer Memory
7.2 Buffer memory details
36
FX
3U
-64CCL User's Manual
7.2.3
[BFM#24] Transmission rate, hardware test set value
This buffer memory address stores the setting contents of the transmission rate/hardware test switch of the
64CCL.
Setting contents are determined when the 64CCL is started. The contents stored in this buffer memory
address do not change when the setting is changed after startup.
BFM#24 Transmission rate, hardware test set value
Setting
(hexadecimal)
Description
Status
0
Transmission rate 156Kbps
Online
1
Transmission rate 625Kbps
2
Transmission rate 2.5Mbps
3
Transmission rate 5Mbps
4
Transmission rate 10Mbps
5 to 9
Unusable
Setting error
A
Transmission rate 156Kbps
Hardware test
B
Transmission rate 625Kbps
C
Transmission rate 2.5Mbps
D
Transmission rate 5Mbps
E
Transmission rate 10Mbps
F
Unusable
Setting error