FX1S Series Programmable Controllers
Installation Notes 3
3-3
1
2
3
4
5
6
7
3.2
FX
1S
RUN/STOP Control
RUN or STOP of the FX
1S
can be controlled by:
"
The RUN/STOP switch mounted next to the programming port.
#
A standard input (X0 to X17) defined by the system parameters.
$
Remotely from a personal computer or other programming peripheral.
Note
:The FX
1S
RUN/STOP switch works in parallel with the RUN input terminal. Please
refer to Table 3.2.
During remote operation the FX
1S
RUN/STOP status is determined by the most recently
operated control.
E.g. If the RUN/STOP switch is in RUN and a remote STOP is made from a personal
computer, the PLC can only be restarted with the RUN/STOP switch by first moving the
switch to STOP and then back to RUN.
Figure 3.2: RUN/STOP Input Wiring Diagram
Table 3.2: Run Status Table
RUN/STOP
SWITCH
➊
RUN INPUT
TERMINAL
FX
1S
MPU
STATUS
✔
✔
RUN
✔
✘
RUN
✘
✘
STOP
✘
✔
RUN
X0
S/S
0V
24V
X1
X0
RUN
➊