![Mitsubishi FR-F500 Instruction Manual Download Page 193](http://html1.mh-extra.com/html/mitsubishi/fr-f500/fr-f500_instruction-manual_1809263193.webp)
PROTECTIVE FUNCTIONS
179
••••
Checking the inverter and converter modules
<Preparation>
1) Disconnect the external power supply cables (R, S, T)
〈
L
1
, L
2
, L
3
〉
and motor cables (U, V, W).
2) Prepare a meter. (Use 100
Ω
range.)
<Checking method>
Change the polarity of the tester alternately at the inverter terminals R, S, T, U, V, W, P and N
〈
L
1
, L
2
, L
3,
U,
V, W,
+
and
−〉
, and check for continuity.
Note: 1. Before measurement, check that the smoothing capacitor is discharged.
2. At the time of continuity, the measured value is several to several ten’s-of ohms depending on the
module type, circuit tester type, etc. If all measured values are almost the same, the modules are
without fault.
<Module device numbers and terminals to be checked>
Tester Polarity
Tester Polarity
Measured Value
Measured Value
R
〈
L
1
〉
P
〈+〉
Discontinuity
R
〈
L
1
〉
N
〈−〉
Continuity
D1
P
〈+〉
R
〈
L
1
〉
Continuity
D4
N
〈−〉
R
〈
L
1
〉
Discontinuity
S
〈
L
2
〉
P
〈+〉
Discontinuity
S
〈
L
2
〉
N
〈−〉
Continuity
D2
P
〈+〉
S
〈
L
2
〉
Continuity
D5
N
〈−〉
S
〈
L
2
〉
Discontinuity
T
〈
L
3
〉
P
〈+〉
Discontinuity
T
〈
L
3
〉
N
〈−〉
Continuity
Convert
e
r m
odul
e
D3
P
〈+〉
T
〈
L
3
〉
Continuity
D6
N
〈−〉
T
〈
L
3
〉
Discontinuity
U
P
〈+〉
Discontinuity
U
N
〈−〉
Continuity
TR1
P
〈+〉
U
Continuity
TR4
N
〈−〉
U
Discontinuity
V
P
〈+〉
Discontinuity
V
N
〈−〉
Continuity
TR3
P
〈+〉
V
Continuity
TR6
N
〈−〉
V
Discontinuity
W
P
〈+〉
Discontinuity
W
N
〈−〉
Continuity
In
vert
er m
odul
e
TR5
P
〈+〉
W
Continuity
TR2
N
〈−〉
W
Discontinuity
(Assumes the use of an analog meter.)
D1
D2
D3
D4
D5
D6
TR1
TR3
TR5
TR4
TR6
TR2
U
V
W
R
〈
L
1
〉
S
〈
L
2
〉
T
〈
L
3
〉
C
P
〈
+
〉
N
〈
–
〉
Inverter module
Converter module