background image

HEAD OFFICE

: MITSUBISHI DENKI BLDG MARUNOUTI TOKYO 100-8310

TELEX : J24532 CABLE MELCO TOKYO

HIMEJI WORKS : 840, CHIYODA CHO, HIMEJI, JAPAN

2.3 Screen Hardware Specifications

3. Installation

Note;

Do not mount the GOT in an environment that contains dust, soot corrosive or conducive
dust, corrosive or flammable gas, or expose the unit to high temperatures, dew
condensation, rain and wind or impact and vibration.
If the GOT is used in such a place, electrical shock, fire, malfunction, damages or
deterioration may be caused.

Never drop cutting chips or electric wire chips into the ventilation window of the GOT when
drilling screw holes or performing wiring. Such chips may cause fire, failure or malfunction.

Make sure that the power is turned off, before securely connecting any cables. Poor
connection may cause malfunction.

The GOT is designed to be mounted in a panel. Install it using the following procedure.

1) Preparing the panel surface. 

On the panel surface, cut a rectangular mounting slot with the
dimensions shown on the right.
At this time, a space of 10 mm is required at each of the top and the
bottom sides of the slot, inside the panel for metal fixtures as shown in
“4) Dimensions required inside the panel for installation”.

Note

Make sure that the thickness of the panel surface is no more than 5 mm (0.20").

2) Inserting the GOT into the panel surface

Attach the packing seal to the GOT, and insert the GOT from the
front face of the panel surface.

a) Packing seal
b) GOT

c)

Mounting slot

3) Fixing the GOT

Put hooks of the mounting brackets (supplied) in to the mounting
holes in the GOT. Tighten mounting bolts (also supplied) until the
GOT is securely fixed.
Fix mounting bolts in all four positions, above and below the GOT.

a) Clamping bolt

b) Mounting bracket

Items

Specifications

Display Device

STN monochrome liquid crystal

Resolution

240 

×

 80 (dot), 30 characters 

×

 5 lines

Dot Pitch

0.47 mm (0.019") Horizontal 

×

 0.47 mm (0.019") Vertical.

Effective Display 
Size

117 mm (4.61") 

×

 42 mm (1.65"); 4 (4.4 inch) type

Number of Colors

2 colors (White and Blue)

Life of liquid crystal

Approximately 50,000 hours
(Operating temperature: 25 

°

C/77

°

F)

Guaranteed term is 1 year. 

Backlight

Cold cathode tube

Life of Backlight

50,000 hours or more
(Operating temperature: 25 

°

C/77

°

F)

Guaranteed term is 1 year. 

Touch Keys

Maximum 50 touch keys / screen, 15 

×

 4 matrix

Keypad

28 keys(0 to 9 keys, Cursor keys, Function keys, SET key, DEV key, ESC key, ENT key)

Interface

RS-422

Conforming to RS-422 (COM0)

RS-232C

Conforming to RS-232C (COM1)

Number of Screens

User screen: 500 screens or less
System screen: Allocated screens No. 1001-1030.

User Memory

Flash memory 256 KB (built-in)

170(6.69")

+1(+0.04")   0

Slot to be

cut on panel

155

+1

  0

+0.04"

  0

(6.10"       )

Unit: mm(inches)

c)

a)

b)

a)

b)

Note:

Make sure to tighten the clamping bolts with a torque of 0.3 ~ 0.5 N

####

m.

4) Peeling of protective sheet

Make sure to peel off the protective sheet on the surface of the product before use.

Dimensions required inside
the panel for installation.
When installing the GOT,
make sure that the inside
dimensions shown on the
right are available.

a) PLC connection cable

b) Packing seal

4. Wiring for Power Supply

Caution:

Cut OFF all phases of power source externally, before installation or wiring work in order to
avoid electric shock or damage to the product.

Note:

When wiring the power supply, use electric wires of 0.75 mm

2

 or more so that voltage

drop will not occur. For crimp-style terminals, use M3 size. Securely tighten crimp-style
terminals with a torque of 0.5 ~ 0.8 N

#

m so that errors will not occur.

Insure correct termination of DC power source, incorrect connection may result in unit
failure or the GOT being burnt.

Attach a fuse of 2 A to the 24V DC power supply. 

Perform grounding (100

Ω 

or less) with an electric wire of at least 1.25 mm

2

.

Never perform common grounding of the GOT and a strong power system.

Note

Feed power to the GOT by an external power supply. 
The service power supply of the programmable controller cannot be used.
(Confirm service power supply capacity of main unit or extension unit is more than the total
value of the current consumption of GOT, extension blocks and special function blocks.)

Even if instantaneous power interruption of less than 5 ms occurs, the GOT continues its
operation. When power interruption for considerable period of time or voltage drop occurs,
the GOT stops its operation. However, when the power supply is recovered, the GOT
automatically restar ts its operation. (The screen displayed just after recovery is
determined by the working environment originally set.)

4.1 Using Service Power Supply of PLC

4.2 Using External Power Supply

Crimp Terminal

Installing 1 wire Per a Terminal

Installing 2 wires Per a Terminal

174

6.85"

189(7.44")

179

7.05"

164(6.46")

94.5(3.72")

20

(0.79")

39.5

(1.56")

67(2.64")

20(0.79")

67(2.64")

104.5(4.11")

20

20

14.5(0.57")

10

108.5(4.27")

20(0.79")

20

(0.79")

14.5 (0.57")

6(0.24")

37.5(1.48")

5(0.20") or less

6.4(0.25")

30(1.18")

(0.79")

(0.39")

(0.79")

(cable)

COM1

RS232C

COM0

RS422

a)

b)

Unit: mm(inches)

24V

0V

PLC

GOT

24V DC

Fuse (2A)

Communication cable

Grounding registance

100

 or less

PLC

GOT

24V DC

Fuse (2A)

24V DC external
power supply

Grounding registance
100

 or less

Grounding registance
100

 or less

Crimp terminal

Terminal screw

Terminal

Crimp terminal

Terminal screw

Terminal

6.2 mm (0.24" )

or less

φ 

3.2 (0.13")

6.2 mm (0.24")

or less

φ 

3.2 (0.13")

5. Maintenance

Cautions:

Correctly connect the battery for memory backup. Never charge, disassemble, heat, burn or
short-circuit the battery. If the battery is handled in such a way, bursting or fire may be caused.

Always power OFF and remove the GOT from the panel before starting the replacement
of the backlight and battery. If this is not the case, the backlight may be dropped and
subsequently cause injury, or electrical shock may be sustained.

Never disassemble or modify the GOT. Disassembly or modification may cause failure,
malfunction or fire. For repair, please, contact a service representative.

Note:

Make sure to turn OFF the power, before connecting/disconnecting cables.
If you connect/disconnect cables while the power is turned on, failure or malfunction may be
caused.

When repairing liquid crystal screen, please, contact a service representative.

5.1 Replacement of Battery

When the battery voltage drops, a control device (system information) set by the screen design software
turns ON. The control device interlocks with an auxiliary relay in the PLC. It is recommended to provide a
lamp while utilizing the output of the PLC so that voltage drop can be monitored outside the GOT.
For details of control devices, refer to the GOT-F900 Series Operation Manual.

Note:

For approximately one month after the control device for battery voltage drop turns ON, the
battery backs up the alarm history, sampling and the current time. When the control device
(system information) turns ON, replace the battery (FX

2NC

-32BL) soon.

The screen data is stored in the flash memory. Even if the battery is totally worn out, the screen
data remains stored

5.1.1 Replacement Procedure

1) Turn off the power to the GOT and remove the battery holder cover.

2) Remove the existing battery from the battery holder, and

disconnect.

3) Within 30 seconds, connect a new battery.

4) Insert the new battery into the battery holder, and attach the cover.

6. Label insert

The clear plastic sheet for labeling Function key can be replaced from the rear of the GOT.
Clarify the user defined key name and operation by using this label.

Label dimensions

COM1

RS232C

FX

2NC

-32BL

Connector

Front panel

Rear panel

Label

Insert Label

COM1

RS232C

COM0

RS422

143(5.63")

30(1.18"

)

10

(0.39"

)

23(0.91")

23(0.91")

23(0.91")

23(0.91")

8

8

C2(0.08")

10

(0.39"

)

(0.31")

8

(0.31")

(0.31")

6(0.24")

C2(0.08")

5

(0.20"

)

2

(0.08"

)

3(0.12")

Insertion
direction.

Unit: mm

Manual number : JY997D02501

Manual revision : B

Date

: July 2002

Summary of Contents for F930GOT-BBD-K-E

Page 1: ...system is correctly configured DO NOT configure emergency stop or safety features to operate through the GOT and be sure that there is no adverse consequences in the event of a GOT PLC communications...

Page 2: ...system is correctly configured DO NOT configure emergency stop or safety features to operate through the GOT and be sure that there is no adverse consequences in the event of a GOT PLC communications...

Page 3: ...system is correctly configured DO NOT configure emergency stop or safety features to operate through the GOT and be sure that there is no adverse consequences in the event of a GOT PLC communications...

Page 4: ...perform common grounding of the GOT and a strong power system Note Feed power to the GOT by an external power supply The service power supply of the programmable controller cannot be used Confirm ser...

Page 5: ...perform common grounding of the GOT and a strong power system Note Feed power to the GOT by an external power supply The service power supply of the programmable controller cannot be used Confirm ser...

Page 6: ...perform common grounding of the GOT and a strong power system Note Feed power to the GOT by an external power supply The service power supply of the programmable controller cannot be used Confirm ser...

Page 7: ...system is correctly configured DO NOT configure emergency stop or safety features to operate through the GOT and be sure that there is no adverse consequences in the event of a GOT PLC communications...

Page 8: ...perform common grounding of the GOT and a strong power system Note Feed power to the GOT by an external power supply The service power supply of the programmable controller cannot be used Confirm ser...

Reviews: