This user's manual explains the specifications, names and setting of parts, wiring 
and others of Type AJ65SBT-64AD analog-digital converter module (hereafter 
abbreviated to the “AJ65SBT-64AD”) which is used as a remote device station of 
a CC-Link system. 
 

 2. Specification 

 

 

2.1 General specifications 

The general specifications of the AJ65SBT-64AD are shown below. 

 

Item Specification 

Usage ambient 
temperature 

0 to 55°C 

Storage ambient 
temperature 

-20 to 75°C 

Usage ambient 
humidity 

10 to 90%RH, no condensation 

Storage ambient 
humidity 

10 to 90%RH, no condensation 

When there is intermittent vibration 

Frequency Acceleration Amplitude Sweep 

count 

10 to 57Hz 

— 

0.075mm 

(0.0030inch) 

57 to 150Hz 

9.8m/s

2

 

— 

10 times in 

each direction 

X, Y, Z 

When there is continuous vibration 

Frequency Acceleration Amplitude Sweep 

count 

10 to 57Hz 

— 

0.035mm 

(0.0014inch) 

Vibration durability 

Conforming to 

JIS B 3502, 

IEC 61131-2 

57 to 150Hz 

4.9m/s

2

 

— 

— 

Shock durability 

Conforming to JIS B 3502, IEC 61131-2  

(147m/s

2

, 3 times each in 3 directions) 

Usage environment 

No corrosive gas 

Usage height *

3

 

Less than 2000m (less than 6562ft.) 

Installation area 

Within the control board 

Over-voltage 
category *

1

 

Less than II 

Pollution level *

2

 

Less than 2 

*1 Indicates the location where the device is connected from the public cable network to the 

device structure wiring area. 
Category II applies to the devices to which the power is supplied from a fixed equipment. 
Surge withstand voltage for devices with up to 300V of rated voltage is 2500V. 

*2 This is an index which indicates the degree of conductive object generation in the 

environment Pollution level 2 is when only non-conductive pollution occurs.  
A temporary conductivity caused by condensation must be expected occasionally. 

*3 Do not operate or store the programmable controller in the environment where the pressure 

applied is equal to greater than the atmospheric pressure at the altitude of 0m. 
Doing so may cause a malfunction. Please consult our branch office when the 
programmable controller is to be operated under pressure. 
 

 

Summary of Contents for AJ65S-64AD-U-H-JE

Page 1: ...the Mitsubishi general purpose programmable controller MELSEC Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MODEL AJ65S 64A...

Page 2: ...derate injury or property damage Under some circumstances failure to observe the precautions given under CAUTION may lead to serious consequences Observe the precautions of both levels because they ar...

Page 3: ...z Ground the FG and FG1 terminals to the protective ground conductor dedicated to the programmable controller Failure to do so may result in malfunction z Tighten any unused terminal screws within th...

Page 4: ...or retightening the terminal screws Failure to do so may cause the module to fail or malfunction Undertightening the terminal screws can cause short circuit or malfunction Overtightening can damage th...

Page 5: ...tion 2 3 Sep 2006 IB NA 0800138 E Partial correction SAFETY PRECAUTIONS Chapter 3 Chapter 7 Dec 2006 IB NA 0800138 F Partial correction Chapter 6 Oct 2008 IB NA 0800138 G Partial correction SAFETY PRE...

Page 6: ...nverter Module Type AJ65SBT 64AD User s Manual SH 080106 13JR18 Compliance with the EMC and Low Voltage Directives 1 For programmable controller system To configure a system meeting the requirements o...

Page 7: ...2 Shock durability Conforming to JIS B 3502 IEC 61131 2 147m s2 3 times each in 3 directions Usage environment No corrosive gas Usage height 3 Less than 2000m less than 6562ft Installation area Within...

Page 8: ...RWw 4 points each Communication cable CC Link dedicated cable Dielectric withstand voltage Between power supply communication system batch and analog input batch 500VAC 1 minute Isolation system Acros...

Page 9: ...30 minutes after power is turned ON 1 Digit indicates digital value 2 Current value indicates value of instant input current that does not break module inner electrical resistance 2 3 Checking hardwar...

Page 10: ...ower supply shutoff or watchdog timer error occurred RUN LED Test mode On Indicates that the SELECT SET switch is in the SET position Flashing 0 1s intervals indicate that the input range setting is n...

Page 11: ...F OFF OFF ON 2 OFF OFF OFF OFF OFF ON OFF 3 OFF OFF OFF OFF OFF ON ON 4 OFF OFF OFF OFF ON OFF OFF 10 OFF OFF ON OFF OFF OFF OFF 11 OFF OFF ON OFF OFF OFF ON 64 ON ON OFF OFF ON OFF OFF Example To set...

Page 12: ...l the A series programmable controller in the following environments 1 Locations where the ambient temperature is outside the range of 0 to 55 C 2 Locations where the ambient humidity is outside the r...

Page 13: ...C Link dedicated cable between the AJ65SBT 64AD and master module as shown below DA DB DG SLD FG DA DB DG SLD FG DA DB DG SLD FG Termination resistor CC Link dedicated cable Master module side AJ65SBT...

Page 14: ...cable However depending on the external noise conditions it may be better have a grounding externally 6 2 Module connection example V I COM SLD 500k 500k 250 V I COM SLD 500k 500k 250 FG1 CH1 4 1 Shie...

Page 15: ...u t 1 0 5 L RUNL ERR CH1 24G DA 24V DG SLD DB AJ65SBT 64AD I V COM COM SLD TEST I V I V TEST SELECT PW RUN 2 3 4 OFFSET GAIN FG I V AG SLD COM COM FG1 SET CH3 CH2 CH1 4 STATION NO 1 B RATE 1 2 2 4 8...

Page 16: ...s Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 South Africa Circuit Breaker Industri...

Reviews: