Mitsubishi AJ65S-64AD-U-H-JE User Manual Download Page 10

 

4

 

 3. Name of Each Part 

 

 
The name of each part in the AJ65SBT-64AD is shown. 

 

PW

RUN L RUN L ERR. CH1 2

OFFSET GAIN

MITSUBISHI

A

J65SBT-64AD

DA DG +24V

24G

DB

SLD

(FG)

TEST

TEST

V+

I+

AG

V+

I+

CH1

CH2

SELECT

SET

STATION   NO.

B   RATE

40 20 10 8   4   2   1 4   2   1

ON

DA

DG

1

3

5

7

24G

DB

SLD

2

4

6

(FG)

+24V

FG1

9

11

13

15

17

19

21

23

25

8

10

12

14

16

18

20

22

24

TEST

TEST

V+

I+

V+

I+

SLD

AG

1)

2)

3)

4)

5)

6)

7)

2-piece
(CC-Link
 communication
 section)

[Terminal numbers and signal names]

3 4

(FG1)

COM

SLD

COM

V+

I+

V+

I+

COM

SLD

COM

CH3

CH4

COM

COM

SLD

COM

COM

V+

I+

V+

I+

Direct-coupled
(Analog I/O section)

 

 

Number 

Name and 

appearance 

Description 

PW LED 

ON   : Power supply on 
OFF : Power supply off 

Normal 
mode 

On 

: Normal operation 

Flashing : 0.1s intervals indicate an input range error. 
Off 

: 24VDC power supply shutoff or watchdog timer 

error occurred. 

RUN LED 

Test  
mode 

On 

: Indicates that the SELECT/SET switch is in the 

SET position. 

Flashing : 0.1s intervals indicate that the input range 

setting is not any of "user range settings 1 to 3".
0.5s intervals indicate that you attempted to 
make offset/gain setting outside the setting 
range. 

Off 

: Indicates that the SELECT/SET switch is in the 

SELECT or center position. 

L RUN 
LED 

On  : Normal communication 
Off  : Communication cutoff (time expiration error) 

1) 

Operation 
status 
display LED 

L ERR. 
LED 

On  : Indicates that transmission speed setting or station number 

setting is outside the range. 

Flicker at fixed intervals  : Indicates that transmission speed 

setting or station number setting was 
changed from that at power-on. 

Flicker at unfixed intervals :  Indicates  that  you  forgot  fitting  the 

termination resistor or the module or 
CC-Link dedicated cable is affected 
by noise. 

Off  : Indicates normal communications. 

 

Summary of Contents for AJ65S-64AD-U-H-JE

Page 1: ...the Mitsubishi general purpose programmable controller MELSEC Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MODEL AJ65S 64A...

Page 2: ...derate injury or property damage Under some circumstances failure to observe the precautions given under CAUTION may lead to serious consequences Observe the precautions of both levels because they ar...

Page 3: ...z Ground the FG and FG1 terminals to the protective ground conductor dedicated to the programmable controller Failure to do so may result in malfunction z Tighten any unused terminal screws within th...

Page 4: ...or retightening the terminal screws Failure to do so may cause the module to fail or malfunction Undertightening the terminal screws can cause short circuit or malfunction Overtightening can damage th...

Page 5: ...tion 2 3 Sep 2006 IB NA 0800138 E Partial correction SAFETY PRECAUTIONS Chapter 3 Chapter 7 Dec 2006 IB NA 0800138 F Partial correction Chapter 6 Oct 2008 IB NA 0800138 G Partial correction SAFETY PRE...

Page 6: ...nverter Module Type AJ65SBT 64AD User s Manual SH 080106 13JR18 Compliance with the EMC and Low Voltage Directives 1 For programmable controller system To configure a system meeting the requirements o...

Page 7: ...2 Shock durability Conforming to JIS B 3502 IEC 61131 2 147m s2 3 times each in 3 directions Usage environment No corrosive gas Usage height 3 Less than 2000m less than 6562ft Installation area Within...

Page 8: ...RWw 4 points each Communication cable CC Link dedicated cable Dielectric withstand voltage Between power supply communication system batch and analog input batch 500VAC 1 minute Isolation system Acros...

Page 9: ...30 minutes after power is turned ON 1 Digit indicates digital value 2 Current value indicates value of instant input current that does not break module inner electrical resistance 2 3 Checking hardwar...

Page 10: ...ower supply shutoff or watchdog timer error occurred RUN LED Test mode On Indicates that the SELECT SET switch is in the SET position Flashing 0 1s intervals indicate that the input range setting is n...

Page 11: ...F OFF OFF ON 2 OFF OFF OFF OFF OFF ON OFF 3 OFF OFF OFF OFF OFF ON ON 4 OFF OFF OFF OFF ON OFF OFF 10 OFF OFF ON OFF OFF OFF OFF 11 OFF OFF ON OFF OFF OFF ON 64 ON ON OFF OFF ON OFF OFF Example To set...

Page 12: ...l the A series programmable controller in the following environments 1 Locations where the ambient temperature is outside the range of 0 to 55 C 2 Locations where the ambient humidity is outside the r...

Page 13: ...C Link dedicated cable between the AJ65SBT 64AD and master module as shown below DA DB DG SLD FG DA DB DG SLD FG DA DB DG SLD FG Termination resistor CC Link dedicated cable Master module side AJ65SBT...

Page 14: ...cable However depending on the external noise conditions it may be better have a grounding externally 6 2 Module connection example V I COM SLD 500k 500k 250 V I COM SLD 500k 500k 250 FG1 CH1 4 1 Shie...

Page 15: ...u t 1 0 5 L RUNL ERR CH1 24G DA 24V DG SLD DB AJ65SBT 64AD I V COM COM SLD TEST I V I V TEST SELECT PW RUN 2 3 4 OFFSET GAIN FG I V AG SLD COM COM FG1 SET CH3 CH2 CH1 4 STATION NO 1 B RATE 1 2 2 4 8...

Page 16: ...s Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 South Africa Circuit Breaker Industri...

Reviews: