background image

 7 

4 System 

Configuration 

The system configuration depends on whether the external I/O unit   

provides outputs or not. 

4.1 

System Configuration for No Outputs 

 

User-fabricated

Inputs

(Originaloperator panel)

GOT

A85

 

GOT

A8GT-50KBF

External I/O unit

Connection cable

DC power supply 12/24V

User-fabricated

 

 

Summary of Contents for A8GT-50KBF

Page 1: ...you for choosing the Mitsubishi General Purpose PC Graphic Operation Terminal 800 series To ensure correct use of this equipment please read this manual carefully before operating it MODEL A8GT 50KBF...

Page 2: ...10 F Manulife Tower 169 Electric Rd North Point Hong Kong Phone 8878870 Singapore Malaysia MELCO Sales Singapore Pte Ltd Industrial Division 307 Alexandra Rd 05 01 02 Mitsubishi Electric Bldg Singapo...

Page 3: ...injury if not carried out properly CAUTION Procedures which may lead to a dangerous condition and cause superficial to medium injury or physical damage only if not carried out properly Depending on ci...

Page 4: ...degradation could occur For a correct installation insert the bus connection cable to this module A7GT BUS2S bus connector conversion module and base unit connector until you hear it click A bad conn...

Page 5: ...op short circuit or malfunction Overtightening could cause the module to drop short circuit or malfunction CAUTION Do not disassemble or modify this module Otherwise a failure malfunction injury or fi...

Page 6: ...A 4 DISPOSAL PRECAUTIONS CAUTION When disposing of this product treat it as industrial waste...

Page 7: ...g This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi electric Corporation cannot be held responsible for any problems i...

Page 8: ...the A850GOT IB 66669 13J847 A852GOT Graphic Operation Terminal User s Manual Packaged with the A852GOT IB 66767 13JL15 A853GOT Graphic Operation Terminal User s Manual Packaged with the A853GOT IB 66...

Page 9: ...nal block conversion unit 10 4 2 3 Connection of external inputs and external outputs to the terminal block conversion 12 5 User fabricasted connection cables 14 5 1 cable for connection between exter...

Page 10: ...the GOT to receive up to 8 64 points of inputs and provide up to 16 points of outputs LAMP GOT 16 points such as lamps and relays Terminal block conversion unit Operator panel pushbuttons DC power su...

Page 11: ...nt 4VDC or less 1mA or less Input resistance Approx 2 4K ON to OFF Approx 0 4ms or less 24VDC Response time 1 OFF to ON Approx 0 4ms or less 24VDC Dynamic scan cycle 13 3ms Output Specifications Outpu...

Page 12: ...oad current varies with the number of simultaneous ON points Refer to the following information Relationships between output load current common current number of simultan eous ON points and ambient t...

Page 13: ...bers and Signal Names of External Connector Pin Number Signal Name Pin Number Signal Name 1A XD7 1B XD6 2A XD5 2B XD4 3A XD3 3B XD2 4A XD1 4B XD0 5A XSCN7 5B XSCN8 6A XSCN5 6B XSCN4 7A XSCN3 7B XSCN2...

Page 14: ...C12 24V 17A 17B 18A Pin number Fuse blown detector circuit Internal control circuit Internal scan is made at 1 8 duty Internal control circuit Internal control circuit 1 A fuse blown error will also b...

Page 15: ...DC12 24V 00 08 10 18 20 28 30 38 Fuse blown detector circuit Input terminals Pin number Internal scan is made at 1 8 duty Internal control circuit Internal control circuit Internal control circuit 1 W...

Page 16: ...depends on whether the external I O unit provides outputs or not 4 1 System Configuration for No Outputs User fabricated Inputs Originaloperator panel GOT A85 GOT A8GT 50KBF External I O unit Connect...

Page 17: ...ck conversion unit A6TBY36 E A6TBY54 E DC poewr supply 12 24V Outputs e g lamps relays Inputs e g pushbuttons GOT A85 GOT A8GT C30TB 1 Connection cable A8GT 50KBF External I O unit 1 The cable for con...

Page 18: ...6TBY36 E A6TBY54 E DC poewr supply 12 24V Connection cable Outputs e g lamps relays External I O unit User fabricated Inputs Original operator panel User fabricated Connection cable 1 The cable for co...

Page 19: ...19B 20A 20B FG 13A XSCN1 XSCN2 XSCN3 XSCN4 XSCN5 XSCN6 XSCN7 YD1 YD2 YD3 YD4 YD5 YD6 YD7 YD10 YD11 YD12 YD13 YD14 YD15 YD8 YD9 LOT24 12 LOT24 12 RTN24 12 RTN24 12 B4 A4 B3 A3 B2 A2 B1 A1 B5 A5 B6 A6 B...

Page 20: ...6 XSCN7 YD1 YD2 YD3 YD4 YD5 YD6 YD7 YD10 YD11 YD12 YD13 YD14 YD15 YD8 YD9 LOT24 12 LOT24 12 RTN24 12 RTN24 12 B4 A4 B3 A3 B2 A2 B1 A1 B5 A5 B6 A6 B7 A7 B8 A8 B9 A9 B10 A10 B11 A11 B12 A12 B13 A13 B14...

Page 21: ...30 28 20 18 10 08 0 XD0 39 31 29 21 19 11 09 01 XD1 3A 32 2A 22 1A 12 0A 02 XD2 3B 33 2B 23 1B 13 0B 03 XD3 3C 34 2C 24 1C 14 0C 0C XD4 3D 35 2D 25 1D 15 0D 05 XD5 3E 36 2E 26 1E 16 0E 06 XD6 3F 37 2...

Page 22: ...25 1D 15 0D 05 XD5 3E 36 2E 26 1E 16 0E 06 XD6 3F 37 2F 27 1F 17 0F 07 XD7 3 4 5 6 7 1 2 C C C C 10 11 8 12 13 14 15 16 17 18 19 1A C C C C C C 1B 1C 1D XSCN0 XSCN1 XSCN2 XSCN3 XSCN4 XSCN5 XSCN6 XSCN7...

Page 23: ...side Shieleded cableconnect with FG Cables for connection of external input power supply DC12 24V Shield External I O unit side 4B 4A 3B 3A 2B 2A 1B 1A 8B 8A 7B 7A 6B 6A 5B 5A 9A 9B 10A 10B 11A 11B 12...

Page 24: ...of the connector of the user fabricated connection cable must be connected to the control box or the like Grounding should be independent where possible Use class 3 grounding method grounding resista...

Page 25: ...OT24 12 RTN24 12 RTN24 12 None 4B 4A 3B 3A 2B 2A 1B 1A 8B 8A 7B 7A 6B 6A 5B 5A 16B 16A 15B 15A 14B 14A 13B 12B 12A 11B 11A 10B 10A 9B 9A 17A 17B 18A 18B 19A 19B 20A 20B 13A 20B 20A 19B 19A 18B 18A 17B...

Page 26: ...cable must be connected to the control box or the like Grounding should be independent where possible Use class 3 grounding method grounding resistance is 100 max The grounding point should be as nea...

Page 27: ...SHI A8GT 50KBF 3 No Name Description 1 I O cable connection interface Interface for connection of the I O cable 2 Unit fixing screws Screws used to fix the unit to the GOT 3 Connector Connector used t...

Page 28: ...Install the external I O module within this distance so that the GOT end connector of the cable may be fitted into the GOT s connector When mounting the external I O module on the back of the control...

Page 29: ...main unit When using the STE The option module can be fitted to the GOT main unit Control box When not using the STE As the option module is used on the control box secure an installation space Contro...

Page 30: ...24 8 Outline Dimension Drawing Unit mm inch MITSUBISHI A8GT 50KBF 42 6 0 13 3 2 0 13 65 2 56 73 2 88 3 5 0 14 92 3 62 105 4 13 9 5 44 1 73 67 8 2 67 500 19 7 0 37...

Page 31: ...25 Appendix Appendix 1 Depth Diagram for Use of the STE A8GT 50STE A85 GOT Option module 6 0 24 109 6 4 32 47 6 1 88 130 5 12 Unit mm inch...

Reviews: