4. AnSHCPU MODULE
4 - 11
MELSEC-A
4.1.6
List of parameter setting ranges
The parameters specify various PLC functions, device ranges and user memory
assignments of the AnSHCPU.
As shown in Table 4.4, the parameters have default settings so the user does not
have to set all the parameter items. If any parameter item needs to be modified,
please refer to the table for the allowed setting range.
The operating manuals for each peripheral device give details on parameter
settings.
Table 4.4 Parameter setting ranges
Setting
Default value
Setting range
Valid peripheral
devices
Item
PU
GPP
A1SJHCPU(S8)
A1SHCPU
6 k steps
1 to 8 k steps
(in units of 1 k steps)
{
{
A2SHCPU(S1)
1 to 14 k steps
(in units of 1 k steps)
{
{
File register capacity
None
1 to 4 k points
(in units of 1 k points)
{
{
Comment capacity
A1SJHCPU(S8)
A1SHCPU
None
0 to 3648 points
(in units of 64 points)
{
A2SHCPU(S1)
0 to 3648 points
(in units of 64 points)
Memory capacity
0/8 to 16 k bytes
Status latch
Data memory
None
Absent/present
{
File register
Absent/present
(2 to 8 k bytes)
Memory capacity
0/8 k bytes
Device setting
Device number
None
Per scan
{
Execution condition
Per time
Sampling trace
Sampling count
0 to 1024 times
(in units of 129 times)
A1SJHCPU
A1SHCPU
None
0 to 14 k bytes
(in units of 2 k bytes)
{
Microcomputer
program capacity
A2SHCPU (S1)
0 to 26 k bytes
(in units of 2 k bytes)
Link relay (B)
B0 to B3FF
(in units of 1 point)
Timer (T)
T0 to T255
(in units of 1 point)
Counter (C)
C0 to C255
(in units of 1 point)
{
{
Data register (D)
D0 to D1023
(in units of 1 point)
Setting of latch
(power
interruption
compensation)
range
Link register (W)
W0 to W3FF
(in units of 1 point)
Number of link stations
1 to 64
Setting of link
range
Input (X)
A1SJHCPU(S8)
A1SHCPU
None
X0 to FF
(in units of 16 points)
{
Main sequence program area
Only for L1000 to
L2047.
None for
others