[Wiring Precautions]

CAUTION

Be sure to shut off all phases of the external power supply used by the 
system before installation or wiring.
Failure to do so may cause a damage to the product and/or malfunctions.
Always ground the FG terminal to the protective ground conductor.
Failure to do so may result in malfunctions.
Be sure to tighten any unused terminal screws within a tightening torque 
range.
Failure to do so may cause a short circuit due to contact with a solderless 
terminal.
Use applicable solderless terminals and tighten them with the specified 
torque.
If any solderless spade terminal is used, it may be disconnected when the 
terminal screw comes loose, resulting in failure.
Check the rated voltage and terminal layout and then wire the module 
correctly.
Connecting a power supply of a different voltage rating or incorrect wiring 
may cause a fire or failure.
Tighten terminal screws within the specified torque range.
A loose terminal screw may cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to damage of the 
screws or module.
Take care to prevent foreign matter such as dust or wire chips from entering 
the module.
Failure to do so may cause a fire, failure or malfunctions.
Place the connection wires and cables in a duct or clamp them.
If not, dangling cables may swing or inadvertently be pulled, resulting in 
damage to the module and/or cables or malfunctions due to poor cable 
connection.

Summary of Contents for 13JY77

Page 1: ...asing the Mitsubishi programmable controller 2008 MITSUBISHI ELECTRIC CORPORATION RTD Input Module Prior to use please read this and relevant manuals thorougly to fully understand the product MODEL AJ...

Page 2: ...user s manual In this manual the safety instructions are ranked as DANGER and CAUTION Note that the CAUTION level may lead to a serious consequence according to the circumstances Always follow the in...

Page 3: ...module in an environment that meets the general specifications given in this manual Operating it in any other environment may cause an electric shock fire malfunction product damage or deterioration F...

Page 4: ...cted when the terminal screw comes loose resulting in failure Check the rated voltage and terminal layout and then wire the module correctly Connecting a power supply of a different voltage rating or...

Page 5: ...ing so can cause the module to fail or malfunction Undertightening can cause a drop short circuit or malfunction Overtightening can cause a drop short circuit or malfunction due to damage of the screw...

Page 6: ...May 2008 IB NA 0800420 A First edition This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot...

Page 7: ...AND SETTINGS 6 3 1 Part Names 6 4 LOADING AND INSTALLATION 9 4 1 Handling Precautions 9 5 DATA LINK CABLE WIRING 11 5 1 Wiring Precautions 11 5 2 CC Link Dedicated Cable Connection Method 11 5 3 Conn...

Page 8: ...y or equipment refer to the EMC AND LOW VOLTAGE DIRECTIVES chapter of the User s Manual for the CPU module used The CE mark indicating compliance with the EMC and Low Voltage Directives is printed on...

Page 9: ...his user s manual explains the specifications names of the components and wiring for the type AJ65SBT2B 64RD3 RTD Input Module hereafter AJ65SBT2B 64RD3 which are used as a remote device station of a...

Page 10: ...atmospheric pressure at the altitude of 0m Doing so may cause a malfunction Please consult our branch office when the programmable controller is to be operated under pressure Table 2 1 General specifi...

Page 11: ...ion RX RY 32 points each RWr RWw 4 points each Connection cable CC Link dedicated cable Withstand voltage 500 V AC for 1 minute across all power supply and communication system terminals and all RTD i...

Page 12: ...tightening torque 59 to 88N cm Applicable solderless terminals 2 max Applicable wire size 0 3 to 2 0mm2 Applicable solderless terminals RAV1 25 3 conforming to JIS C 2805 Applicable wire size 0 3 to...

Page 13: ...conversion accuracy Degree of tolerance of RTD Refer to Table 2 3 1 40 0 15 0 002 800 3 15 Because the resolution is 0 1 3 2 t Measured temperature Table 2 3 Degree of tolerance of RTD Resistance the...

Page 14: ...6 3 PART NAMES AND SETTINGS 3 1 Part Names This section explains the names of the components for the AJ65SBT2B 64RD3 Figure 3 1 Appearance of the AJ65SBT2B 64RD3...

Page 15: ...subtracted from the gain value Indicates that the SELECT SET switch is in the SELECT or center position L RUN LED On Normal communication Off Communication cutoff time expiration error L ERR LED On F...

Page 16: ...32 set the switches as indicated below Use prohibited Set all station number to OFF Terminal block Used to connect the module power supply transmission and analog I O signals DIN rail hook Used to mo...

Page 17: ...the screw resulting in a short circuit or malfunction When disposing of this product treat it as industrial waste Use the module in an environment that meets the general specifications given in this m...

Page 18: ...5SBT2B 64RD3 to the DIN rail press with your finger the centerline of the DIN rail hook at the bottom of the module until it clicks Figure 4 1 Installation to DIN rail 4 Refer to the Master Module use...

Page 19: ...s no need the external wiring 1 Precautions a Move the L TER switch until it clicks b Make sure that between DA and DB is high resistance when the L TER switch is off or is 110 When the L TER switch i...

Page 20: ...TD at least 10cm away from the main circuit cables and AC control circuit lines Fully keep it away from high voltage cables and circuits which include high frequency waves such as an inverter s load c...

Page 21: ...ERNAL DIMENSIONS The external dimensions of the AJ65SBT2B 64RD3 is shown below Unit mm inch DIN rail center 109 5 0 5 4 31 0 02 2 4 5 5 1M4 16 5 0 65 50 1 97 4 5 0 18 7 9 0 31 7 5 0 30 1 0 5 122 4 80...

Page 22: ...Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B...

Reviews: