background image

Warranty

Mitsubishi will not be held liable for damage caused by factors found not to be the cause of 

Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, 
secondary damage, accident compensation caused by special factors unpredictable by 
Mitsubishi; damages to products other than Mitsubishi products; and to other duties.

For safe use

• This product has been manufactured as a general-purpose part for general industries, and 

has not been designed or manufactured to be incorporated in a device or system used in 
purposes related to human life. 

• Before using the product for special purposes such as nuclear power, electric power, 

aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.

• This product has been manufactured under strict quality control. However, when installing the 

product where major accidents or losses could occur if the product fails, install appropriate 
backup or failsafe functions in the system.

Country/Region Sales office/Tel

Specifications subject to change without notice.

Country/Region Sales office/Tel

U.S.A 

Mitsubishi Electric Automation Inc.

 

500 Corporate Woods Parkway Vernon 

 

Hills, IL 60061, U.S.A.

 

Tel : +1-847-478-2100

Brazil   

MELCO-TEC Rep. Com.e Assessoria  

 Tecnica 

Ltda.

 

Rua Correia Dias, 184,  

 

Edificio Paraiso Trade Center-8 andar 

 

Paraiso, Sao Paulo, SP Brazil

 

Tel : +55-11-5908-8331

Germany   

Mitsubishi Electric Europe B.V. German 

 Branch
 

Gothaer Strasse 8 D-40880 Ratingen,  

 GERMANY
 

Tel : +49-2102-486-0

U.K 

Mitsubishi Electric Europe B.V. UK  

 Branch
 

Travellers Lane, Hatfield, Hertfordshire.,  

 

AL10 8XB, U.K.

 

Tel : +44-1707-276100

Italy 

Mitsubishi Electric Europe B.V. Italian  

 Branch
 

Centro Dir. Colleoni, Pal. Perseo-Ingr.2

 

Via Paracelso 12, I-20041 Agrate Brianza.,  

 Milano, 

Italy

 

Tel : +39-039-60531

Spain   

Mitsubishi Electric Europe B.V. Spanish  

 Branch
 

Carretera de Rubi 76-80,

 

E-08190 Sant Cugat del Valles,  

 Barcelona, 

Spain

 

Tel : +34-93-565-3131

France   

Mitsubishi Electric Europe B.V. French  

 Branch
 

25, Boulevard des Bouvets, F-92741  

 

Nanterre Cedex, France

 TEL: 

+33-1-5568-5568

South Africa  

Circuit Breaker Industries Ltd.

 

Private Bag 2016, ZA-1600 Isando,  

 South 

Africa

 

Tel : +27-11-928-2000

Hong Kong  

Mitsubishi Electric Automation 

 

(Hong Kong) Ltd.

 

10th Floor, Manulife Tower, 169 Electric

 

Road, North Point, Hong Kong

 

Tel : +852-2887-8870

China Mitsubishi 

Electric 

Automation 

 (Shanghai) 

Ltd.

 

4/F Zhi Fu Plazz, No.80 Xin Chang Road,

 

Shanghai 200003, China

 

Tel : +86-21-6120-0808

Taiwan   

Setsuyo Enterprise Co., Ltd.

 

6F No.105 Wu-Kung 3rd.Rd, Wu-Ku 

 Hsiang, 

Taipei 

Hsine, 

Taiwan

 

Tel : +886-2-2299-2499

Korea   

Mitsubishi Electric Automation Korea Co., Ltd.

 

1480-6, Gayang-dong, Gangseo-ku 

 

Seoul 157-200, Korea

 

Tel : +82-2-3660-9552

Singapore 

Mitsubishi Electric Asia Pte, Ltd.

 

307 Alexandra Road #05-01/02, Mitsubishi 

 

Electric Building, Singapore 159943

 

Tel : +65-6470-2460

Thailand   

Mitsubishi Electric Automation (Thailand) 

 Co., 

Ltd.

 

Bang-Chan Industrial Estate No.111 

 

Moo 4, Serithai Rd, T.Kannayao, 

 

A.Kannayao, Bangkok 10230 Thailand

 

Tel : +66-2-517-1326

Indonesia P.T. 

Autoteknindo 

Sumber 

Makmur

 

Muara Karang Selatan, Block A/Utara 

 

No.1 Kav. No.11 Kawasan Industri 

 

Pergudangan Jakarta - Utara 14440, 

 

P.O.Box 5045 Jakarta, 11050 Indonesia

 

Tel : +62-21-6630833

India   

Messung Systems Pvt, Ltd.

 

Electronic Sadan NO:III Unit No15, 

 

M.I.D.C Bhosari, Pune-411026, India

 

Tel : +91-20-2712-3130

Australia   

Mitsubishi Electric Australia Pty. Ltd.

 

348 Victoria Road, Rydalmere, 

 N.S.W 

2116, 

Australia

 

Tel : +61-2-9684-7777

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN

When exported from Japan, this manual does not require application to the Ministry 
of Economy, Trade and Industry for service transaction permission.

Summary of Contents for 13JY77

Page 1: ...asing the Mitsubishi programmable controller 2008 MITSUBISHI ELECTRIC CORPORATION RTD Input Module Prior to use please read this and relevant manuals thorougly to fully understand the product MODEL AJ...

Page 2: ...user s manual In this manual the safety instructions are ranked as DANGER and CAUTION Note that the CAUTION level may lead to a serious consequence according to the circumstances Always follow the in...

Page 3: ...module in an environment that meets the general specifications given in this manual Operating it in any other environment may cause an electric shock fire malfunction product damage or deterioration F...

Page 4: ...cted when the terminal screw comes loose resulting in failure Check the rated voltage and terminal layout and then wire the module correctly Connecting a power supply of a different voltage rating or...

Page 5: ...ing so can cause the module to fail or malfunction Undertightening can cause a drop short circuit or malfunction Overtightening can cause a drop short circuit or malfunction due to damage of the screw...

Page 6: ...May 2008 IB NA 0800420 A First edition This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot...

Page 7: ...AND SETTINGS 6 3 1 Part Names 6 4 LOADING AND INSTALLATION 9 4 1 Handling Precautions 9 5 DATA LINK CABLE WIRING 11 5 1 Wiring Precautions 11 5 2 CC Link Dedicated Cable Connection Method 11 5 3 Conn...

Page 8: ...y or equipment refer to the EMC AND LOW VOLTAGE DIRECTIVES chapter of the User s Manual for the CPU module used The CE mark indicating compliance with the EMC and Low Voltage Directives is printed on...

Page 9: ...his user s manual explains the specifications names of the components and wiring for the type AJ65SBT2B 64RD3 RTD Input Module hereafter AJ65SBT2B 64RD3 which are used as a remote device station of a...

Page 10: ...atmospheric pressure at the altitude of 0m Doing so may cause a malfunction Please consult our branch office when the programmable controller is to be operated under pressure Table 2 1 General specifi...

Page 11: ...ion RX RY 32 points each RWr RWw 4 points each Connection cable CC Link dedicated cable Withstand voltage 500 V AC for 1 minute across all power supply and communication system terminals and all RTD i...

Page 12: ...tightening torque 59 to 88N cm Applicable solderless terminals 2 max Applicable wire size 0 3 to 2 0mm2 Applicable solderless terminals RAV1 25 3 conforming to JIS C 2805 Applicable wire size 0 3 to...

Page 13: ...conversion accuracy Degree of tolerance of RTD Refer to Table 2 3 1 40 0 15 0 002 800 3 15 Because the resolution is 0 1 3 2 t Measured temperature Table 2 3 Degree of tolerance of RTD Resistance the...

Page 14: ...6 3 PART NAMES AND SETTINGS 3 1 Part Names This section explains the names of the components for the AJ65SBT2B 64RD3 Figure 3 1 Appearance of the AJ65SBT2B 64RD3...

Page 15: ...subtracted from the gain value Indicates that the SELECT SET switch is in the SELECT or center position L RUN LED On Normal communication Off Communication cutoff time expiration error L ERR LED On F...

Page 16: ...32 set the switches as indicated below Use prohibited Set all station number to OFF Terminal block Used to connect the module power supply transmission and analog I O signals DIN rail hook Used to mo...

Page 17: ...the screw resulting in a short circuit or malfunction When disposing of this product treat it as industrial waste Use the module in an environment that meets the general specifications given in this m...

Page 18: ...5SBT2B 64RD3 to the DIN rail press with your finger the centerline of the DIN rail hook at the bottom of the module until it clicks Figure 4 1 Installation to DIN rail 4 Refer to the Master Module use...

Page 19: ...s no need the external wiring 1 Precautions a Move the L TER switch until it clicks b Make sure that between DA and DB is high resistance when the L TER switch is off or is 110 When the L TER switch i...

Page 20: ...TD at least 10cm away from the main circuit cables and AC control circuit lines Fully keep it away from high voltage cables and circuits which include high frequency waves such as an inverter s load c...

Page 21: ...ERNAL DIMENSIONS The external dimensions of the AJ65SBT2B 64RD3 is shown below Unit mm inch DIN rail center 109 5 0 5 4 31 0 02 2 4 5 5 1M4 16 5 0 65 50 1 97 4 5 0 18 7 9 0 31 7 5 0 30 1 0 5 122 4 80...

Page 22: ...Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B...

Reviews: