ELEC
DIESEL
18
-
-
• When AUTO START/STOP is selected
Setting temperature
is maintained by
repeating ON-OFF
operation.
Fixed
Fixed
Setting temperature
is maintained by
repeating cooling
and heating.
• When CONT. RUN is selected
The sub-engine runs at two speeds. It starts by
pressing the cabin controller’s [RUN/STOP] switch
and when the room temperature is higher than the
temperature set on the thermostat, it runs at high
speed cooling, then changes to low speed cooling
when the room temperature nears the setting
temperature and stops automatically when the
temperature drops to 1ºC lower than the setting
temperature. When the room temperature is lower
than the temperature set on the thermostat, it
changes to high speed heating, then when the
temperature nears the setting temperature, it
changes to low speed heating, then stops
automatically when the temperature becomes 1ºC
lower than the setting temperature.
It starts by pressing the cabin controller’s
[RUN/STOP] switch and when the room
temperature is higher than the temperature set on
the thermostat, it begins a cooling operation. When
the room temperature is below the setting
temperature, it carries out a heating operation
automatically.
Furthermore, it runs continuously, changing back
and forth continuously between low speed cooling
when the temperature is higher than the setting
temperature and low speed heating when the
temperature is lower than the setting temperature.
ADVICE
Select this only for refrigerated
products, and do not select for frozen
products.
Each switch Operation
Selector switch for sub-engine driving or motor
drive.
5
ELEC/DIESEL changeover switch