![Mitsubishi Heavy Industries TNW4E Operation Manual Download Page 17](http://html1.mh-extra.com/html/mitsubishi-heavy-industries/tnw4e/tnw4e_operation-manual_1812153017.webp)
Mode Display
(10) Displaying the log setting
Press the [UP] switch or [DOWN] switch. The display will change to the running log interval display.
Displaying the log setting
Running log interval
setting display
Stopped log interval
setting display
1
•
3
•
6
1
2
3
4
5
6
7
8
2
•
4
•
7
5
•
8
Press the [MODE] switch (13 times if the refrigeration unit is stopped and 12 times if it is running) to
change the digital display to the log setting display.
The log setting display mode displays the fixed time interval (in minutes) when the log of the
refrigeration unit’s data are recorded while it is running and while it is stopped. In the setting mode, the
interval can be changed. If the optional printer is connected, the recorded log can be printed out.
If the [MODE] switch is pressed, the digital display will
blink and it will be possible to change the setting.
Finalize the setting by pressing the [SET] switch. After
the setting is finalized, the digital display will display
the setting temperature/room temperature. If the
refrigeration unit is stopped, the display will change to
the time display.
Finalize the setting by pressing the [SET] switch. The
display will change to the Stopped log interval display.
If the [MODE] switch is pressed, the digital display will
blink and it will be possible to change the setting.
Set the desired interval (in minutes) displayed in the bottom row of
the digital display by pressing the [UP] switch or [DOWN] switch.
Set the desired interval (in minutes) displayed in the bottom row of
the digital display by pressing the [UP] switch or [DOWN] switch.
The log is stored in the cabin controller’s flash memory, but if the memory’s capacity is
exceeded, the log will be overwritten, so exercise caution. It is possible to record the log for a
period of 2 months when in the default setting.
ADVICE
The log setting time interval can be set at 1 ~ 60 min.
ADVICE
The log setting time interval can be set at 1 ~ 60 min.
CAUTION
14
-
-
TSJ012A149A英トンボPDF 16.8.31 10:21 AM ページ 14