151 / 155
Service Manual Mitsubishi L-Series diesel engines
Version 08/2004
SPECIFICATIONS AND MAINTENANCE
STANDARDS
ENGLISH
SERVICE SPECIFICATIONS AND
STANDARDS
Unit: mm (in.)
Description
Specification and Standard
Repair Limit Service Limit
Glow plug indicator (Quick-heat type) for L3
Type
Red-hot type
Model DH-139V-29
Rated current
29A
Voltage across terminals (at 29A)
1.7V±0.2V
Fuel cutoff solenoid
Type
Electromagnetic ETS push type
Coil resistance
1.6
Ω
±10% (at 20°C [68°F])
Working voltage
10 to 15V DC
Stroke
10±0.5 [0.3937±0.0197]
Temperature range
–30 to 120°C [–22 to 248°F]
Fuel cutoff solenoid
Type
Electromagnetic ETR pull type
Rated voltage
12V DC
Rated temperature
20°C [68°F]
Coil resistance
Pull 0.25
Ω
±10% Hold 13.5
Ω
±10%
Rated pull current
55A
Rated hold current
1A
Control timer
Input voltage
9V to 15V DC
Load
Solenoid (Coil resistance 1.7
Ω
or more)
Working temperature
–30 to 80°C [–22 to176°F]
Glow timer
Model
S81NJ
Rated voltage
12V DC
Working temperature
–40 to 85°C [–40 to 185°F]
Initial characteristic
(Normal temperature, normal
humidity, Vcc = 12V)
6
sec.
Environmental characteristic
(–30°C to 70°C [–22°F to 158°F],
Vcc = 7 to 15V)
6
sec.
Glow relay
Model
G71S P
Rated voltage
12 V DC
Continous rating
1 minute
Coil resistance
13
Ω
Inductance
24 mH (at 1 KHz)
Working temperature
-40 to 100°C [-40 to 212°F]
(70 to 100°C [158 to 212°F] for 20 sec. or less
continued use)
+1.4
-0
+2.0
-0.6
Summary of Contents for L2
Page 1: ...MITSUBISHI DIESEL ENGINE SERVICE MANUAL L2 L3 MODELS MITSUBISHI HEAVY INDUSTRIES LTD 08 2004 ...
Page 11: ...10 155 Service Manual Mitsubishi L Series diesel engines Version 08 2004 ENGLISH ...
Page 12: ...11 155 Service Manual Mitsubishi L Series diesel engines Version 08 2004 ENGLISH GENERAL ...
Page 86: ...85 155 Service Manual Mitsubishi L Series diesel engines Version 08 2004 ENGLISH FUEL SYSTEM ...
Page 114: ...113 155 Service Manual Mitsubishi L Series diesel engines Version 08 2004 ENGLISH AIR CLEANER ...