136 / 155
Service Manual Mitsubishi L-Series diesel engines
ENGLISH
ALTERNATOR AND DYNAMO
ELECTRICAL SYSTEM
2.
Inspecting the regulator alone
To judge if the regulator itself is acceptable or not,
check the regulator for normal continuity by
connecting the circuit tester to the lead wires as
follows:
33.10.3 Installation
Heat tremendously affects the regulator and the
rectifier. Therefore it is necessary to install them in a
well-ventilated area. reassemble the regulator in the
proper direction by positioning the head of the outlet
leads downward.
Figure 147 Lead outlet coupler
Blue lead
Red lead
Yellow lead
Green lead
Blue lead
Black lead
Item
Normal
measure
-ment
If abnormal
– possible
cause of
regulator
trouble
Tester (+)
Tester (–)
Red
Blue 1
Continuity
Broken diode
Red
Blue 2
Blue 1
Black
Blue 2
Black
Blue 1
Red
Non-
continuity
Shorted diode
Blue 2
Red
Black
Blue 1
Shorted diode
or thyristor
Black
Blue 2
Table 52
Inspection of the regulator
NOTE
For testing, use an ohmmeter as the circuit tester.
Summary of Contents for L2
Page 1: ...MITSUBISHI DIESEL ENGINE SERVICE MANUAL L2 L3 MODELS MITSUBISHI HEAVY INDUSTRIES LTD 08 2004 ...
Page 11: ...10 155 Service Manual Mitsubishi L Series diesel engines Version 08 2004 ENGLISH ...
Page 12: ...11 155 Service Manual Mitsubishi L Series diesel engines Version 08 2004 ENGLISH GENERAL ...
Page 86: ...85 155 Service Manual Mitsubishi L Series diesel engines Version 08 2004 ENGLISH FUEL SYSTEM ...
Page 114: ...113 155 Service Manual Mitsubishi L Series diesel engines Version 08 2004 ENGLISH AIR CLEANER ...