background image

 

WS0-CPU000200/WS0-CPU130202/WS0-CPU320202 

Safety Controller CPU Module  

User's Manual (Hardware)

 

 
Mitsubishi Electric Corporation 
2-7-3 Marunouchi, Chiyoda-ku, Tokyo, Japan 
Mitsubishi Electric Europe B.V. 
Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany 
All rights reserved • Specified product properties and technical data do not 
represent a guarantee declaration. 

 

MODEL 

WS-CPU-U-HW-E 

MODEL CODE 

13JZ91 

IB(NA)-0800527ENG-E(2206)SICK 

© 2014 MITSUBISHI ELECTRIC CORPORATION 

Precautions regarding warranty and specifications 

MELSEC-WS series products were jointly developed and manufactured 
by Mitsubishi and SICK AG, Industrial Safety Systems, in Germany. Note 
that there are some precautions regarding warranty and specifications of 
MELSEC-WS series products. 

 

<

Warranty> 

  The gratis warranty term of the product shall be for one (1) year after the 

date of delivery or for eighteen (18) months after manufacturing, 
whichever is less. 

  The onerous repair term after discontinuation of production shall be for 

four (4) years. 

  Mitsubishi shall mainly replace the product that needs a repair. 

  It may take some time to respond to the problem or repair the product 

depending on the condition and timing. 

 

<Specifications> 

  General specifications of the products differ. 

 

MELSEC-WS 

MELSEC-Q 

MELSEC-QS 

Operating ambient 
temperature 

Température 
ambiante de 
fonctionnement 

-25 to 55°C

*1 

-25 à 55°C

*1

 

0 to 55°C 

0 à 55°C 

0 to 55°C 

0 à 55°C

 

Operating ambient 
humidity 

10 to 95%RH 

5 to 95%RH 

5 to 95%RH 

Storage ambient 
temperature 

-25 to 70°C 

-25 to 75°C 

-40 to 75°C 

Storage ambient 
humidity 

10 to 95%RH 

5 to 95%RH 

5 to 95%RH 

 

*1: When the WS0-GCC100202 is included in the system, operating 

ambient temperature will be 0 to 55°C. 

*1: Avec un module WS0-GCC100202 inclus dans le système, la 

température ambiante de service est de 0 à 55°C. 

 

  EMC standards that are applicable to the products differ. 

 

MELSEC-WS 

MELSEC-Q,  

MELSEC-QS 

EMC standards 

EN 61000-6-2, EN 55011 

EN 61131-2 

1  About this document 

This document is the original manual. 

1.1  Documentations for the MELSEC-WS system 

This manual describes the mounting of the CPU module of a MELSEC-
WS safety controller.  
Mounting of the MELSEC-WS network modules (WS0-GETH and WS0-
GCC1), safety I/O modules (WS0-XTIO and WS0-XTDI) and the relay 
output module (WS0-4RO) is described in separate manuals.  
The installation, configuration and commissioning of the MELSEC-WS 
safety controller are described in the "Safety Controller User’s Manual" 
and "Safety Controller Setting and Monitoring Tool Operating Manual". 

 

Title 

Number 

Safety Controller User’s Manual 

WS-CPU-U-E 

(13JZ32) 

Safety Controller Ethernet Interface 
User’s Manual 

WS-ET-U-E 

(13JZ33) 

Safety Controller CC-Link Interface 
User’s Manual 

WS-CC-U-E 

(13JZ45) 

Safety Controller Setting and Monitoring 
Tool Operating Manual 

SW1DNNWS0ADR-B-O-E 

(13JU67) 

 

1.2  Function of this document 

This manual instructs the technical staff of the machine manufacturer 
and/or of the machine operator on the safe operating of the CPU module 
of the MELSEC-WS safety controller. 
In addition mounting protective devices also requires specific technical 
skills which are not detailed in this documentation. 
This manual does not provide instructions for operating the machine in 
which the safety controller is, or will be, integrated. Information of this kind 
will be found in the manuals for the machine. 

2 On 

safety 

This chapter deals with your own safety and the safety of the equipment 
operators. 

  Please read this chapter carefully before beginning with the installation. 

2.1 Qualified safety personnel 

The MELSEC-WS safety controller may only be installed by qualified 
safety personnel. 
Qualified safety personnel are defined as persons who … 

  have undergone the appropriate technical training 

and

 

  who have been instructed by the responsible machine operator in the 

operation of the machine and the current valid safety guidelines 

and

 

  have access to the MELSEC-WS manuals and have read and 

familiarized themselves with them 

and

 

  have access to the manuals for the protective devices (e.g. light 

curtains) connected to the safety controller and have read and 
familiarized themselves with them. 

2.2  Applications of the device 

The MELSEC-WS safety controller is a configurable controller for safety 
applications. It can be used  

  in accordance with IEC 61508 to SIL 3 

  in accordance with IEC 62061 to SILCL 3 

  in accordance with EN/ISO 13849-1 up to Performance Level e 

 

The degree of safety actually attained depends on the external circuit, the 
realization of the wiring, the parameter configuration, the choice of the 
pick-ups and their location at the machine. 
Opto-electronic and tactile safety sensors (e.g. light curtains, laser 
scanners, safety switches, sensors, emergency-stop buttons) are 
connected to the safety controller and are linked logically. The 
corresponding actuators of the machines or systems can be switched off 
safely via the switching outputs of the safety controller. 

 

2.3 Correct use 

 

 

ATTENTION

 

The MELSEC-WS safety controller fulfils the 
requirements of Class A (industrial applications) in 
accordance with the "Interference emission" basic 
specifications! 

Le contrôleur de sécurité MELSEC-WS a été conçu en 
conformité aux exigences des appareils de Classe A 
(applications industrielles) pour ce qui concerne les 
spécifications de base dans le domaine des 
"émissions d'interférences" !

 

The MELSEC-WS safety controller is therefore only 
suitable for use in an industrial environment and not for 
private use. 

Le contrôleur de sécurité MELSEC-WS peut donc s'utiliser 
dans un environnement industriel mais n'a pas été prévu 
pour un usage domestique.

 

 

 

The MELSEC-WS safety controller may only be used within specific 
operating limits (voltage, temperature, etc., refer to the technical data and 
to the section "Application areas of the device"). It may only be used by 
qualified safety personnel and only at the machine at which it was 
mounted and initially commissioned by qualified safety personnel in 
accordance with the "Safety Controller User’s Manual". 
The modules of the MELSEC-WS safety controller conform to Class A, 
Group 1, in accordance with EN 55011. Group 1 encompasses all the ISM 
devices in which intentionally generated and/or used conductor-bound RF 
energy that is required for the inner function of the device itself occurs. 
Mitsubishi Electric Corporation accepts no claims for liability if the 
equipment is used in any other way or if modifications are made to the 
device, even in the context of mounting and installation. 
 
UL/CSA applications: 

  Use 60°C/75°C conductors. 

  The terminal tightening torque must be 5-7 lbs in. 

  To be used in a Pollution Degree 2 environment only. 

  Memory plug and CPU module shall be supplied by an isolating power 

source protected by an UL248 fuse, rating 42.4VDC which is the 
maximum voltage requirements of UL508. 

  The safety functions are not evaluated by UL. The approval is 

accomplished according to UL508, general use applications. 

Applications UL/CSA: 

 

Utiliser des conducteurs 60°C/75°C. 

 

Le couple de serrage des bornes doit être de 5-7 lbs in. 

 

À utiliser uniquement en environnement polluant de degré 2. 

 

La prise mémoire et le module CPU doivent être alimentés à partie 

d'une source isolée protégé par un fusible UL248, d'un' tension 
nominale de 42,2V cc, ce qui est le maximum admissible pour UL508. 

 

Les fonctions de sécurité n'ont pas été évaluées par UL. L'agrément a 

été accordé selon UL508 pour applications universelles. 

2.4  General protective notes and protective measures 

 

 

ATTENTION

 

Observe the protective notes and measures! 

Respecter les consignes de sécurité et mesures de 
protection !

 

Please observe the following items in order to ensure 
proper use of the MELSEC-WS safety controller. 

Pour garantir une utilisation correcte du contrôleur de 
sécurité MELSEC-WS, veuillez observer les points 
suivants.

 

 

 

  When mounting, installing and using the MELSEC-WS safety controller, 

observe the standards and directives applicable in your country. 

  The national rules and regulations apply to the installation, use and 

periodic technical inspection of the MELSEC-WS safety controller, in 
particular: 
–  Machinery Directive 2006/42/EC 
–  EMC Directive 2004/108/EC (valid until April 19th, 2016) 
–  EMC Directive 2014/30/EU (valid as of April 20th, 2016) 
–  Use of Work Equipment Directive 2009/104/EC 
–  Low-Voltage Directive 2006/95/EC (valid until April 19th, 2016) 
–  Low-Voltage Directive 2014/35/EU (valid as of April 20th, 2016) 
–  Work safety regulations/safety rules 

  Manufacturers and owners of the machine on which a MELSEC-WS 

safety controller is used are responsible for obtaining and observing all 
applicable safety regulations and rules. 

  It is imperative that the notices, in particular the test notices of the 

manual must be observed. 

 
 
 

 

  The tests must be carried out by qualified safety personnel or specially 

qualified and authorized personnel and must be recorded and 
documented to ensure that the tests can be reconstructed and retraced 
at any time by third parties. 
 

2.5 Disposal 

Disposal of unusable or irreparable devices should always occur in 
accordance with the applicable country-specific waste-disposal regulations 
(e.g. European Waste Code 16 02 14). 

3  Conditions of use for the product 

(1)  Although MELCO has obtained the certification for Product's 

compliance to the international safety standards IEC 61508, EN 954-
1/ISO 13849-1 from TUV Rheinland, this fact does not guarantee that 
Product will be free from any malfunction or failure. The user of this 
Product shall comply with any and all applicable safety standard, 
regulation or law and take appropriate safety measures for the system 
in which the Product is installed or used and shall take the second or 
third safety measures other than the Product. MELCO is not liable for 
damages that could have been prevented by compliance with any 
applicable safety standard, regulation or law. 

(2)  MELCO prohibits the use of Products with or in any application 

involving, and MELCO shall not be liable for a default, a liability for 
defect warranty, a quality assurance, negligence or other tort and a 
product liability in these applications. 

1) power plants, 
2) trains, railway systems, airplanes, airline operations, other 

transportation systems, 

3) hospitals, medical care, dialysis and life support facilities or 

equipment, 

4) amusement equipment, 
5) incineration and fuel devices, 
6) handling of nuclear or hazardous materials or chemicals, 
7) mining and drilling, 
8) and other applications where the level of risk to human life, health 

or property are elevated. 

4 Product 

description 

4.1  CPU modules WS0-CPU0, WS0-CPU1 and WS0-

CPU3 

The CPU modules WS0-CPU0, WS0-CPU1 or WS0-CPU3 are the central 
process unit of the entire system in which all the signals are monitored 
and processed logically in accordance with the configuration stored in the 
memory plug. The outputs of the system are switched as a result of the 
processing, whereby the  backplane bus serves as the data 
interface.  
The memory plug has to be ordered separately, refer to the "Safety 
Controller User’s Manual". 
The CPU modules further more have an RS-232 interface with the 
following functions: 

  Transferring the configuration from the MELSEC-WS Setting and 

Monitoring Tool to the memory plug or the connected SICK EFI-
compatible device 

  Uploading the configuration from the memory plug or the connected 

SICK EFI-compatible device to the MELSEC-WS Setting and 
Monitoring Tool 

  Online monitoring of the MELSEC-WS safety controller 

The WS0-CPU1 and WS0-CPU3 modules have two more EFI interfaces. 
If SICK EFI-compatible devices are connected, a functional extension at 
the sensors is then possible by simple means. 
The WS0-CPU3 module has following interfaces as well. 

  USB interface for the settings and diagnostics using the MELSEC-WS 

Setting and Monitoring Tool  

  Flexi Line interface that enables safety communications between 

MELSEC-WS safety controllers 

Reviews: