EN-36
Problem
The exhaust vents
emit warm air.
No audio is output.
The menu can’t be
used.
“TEMPERATURE!!” is
displayed.
The mark appears.
The remote control
doesn’t function easily
or at all.
The buttons on the
control panel (except
for the POWER
button) don’t function.
Abnormal sound is
heard.
Images are not displayed correctly. (continued)
Solution
• Some signals may be recognized wrongly as XGA60 signal. In such cases, carry out
the following procedure.
1. Set WXGA in the FEATURE menu to AUTO.
2. Display an image with many characters such as HELP menu.
3. Press the AUTO POSITION button.
If images are still recognized wrongly:
•
Set WXGA in the FEATURE menu manually depending on input signal. (See page 24.)
• The input signal may be an inapplicable signal. Change the signal format of the
computer.
• When WXGA in the FEATURE menu is set to other than OFF, it may take long time to
detect WXGA signal or may cause misclassifi cation of signals. In such cases, set it to
OFF.
Problem
Images of WXGA
signal are not
displayed correctly.
It takes abnormally
long time to display
images of signals
other than WXGA, or
the images are not
displayed correctly.
Others
Solution
• This air comes out after cooling the inside of the projector. You may feel hot, but this is
not a malfunction.
• Check that the volume isn’t set to low.
• The microcomputers inside the projector may be wrongly operating because of noise.
Turn off the main power, wait about 10 minutes, and turn on the main power again.
• This indication appears when the ambient temperature rises high. When the ambient
temperature stays high, the lamp goes out.
Eliminate any causes of the rise in the ambient temperature.
• This indication appears when the air inlet or outlet grille is blocked. When they are kept
blocked, the lamp goes out.
Remove the objects blocking the air inlet or outlet grille.
• This mark appears when ineffective operation is carried out. This isn’t a product
malfunction.
• Check that the batteries are loaded in the remote control or the batteries are not weak.
(See page 6.)
• Check that the remote control sensor isn’t exposed to direct sunlight or fl uorescent
light. (See page 9.)
• Use the remote control within its operation range. (See page 9.)
• Use the remote control at least 10 cm away from the projector.
• PASSWORD FUNCTION in the FEATURE menu has been set to MENU ACCESS to en-
able the password lock.
Cancel the password lock or contact the person in charge of management of the
projector. (See page 28.)
• Because the color wheel spins at a high speed, metallic sounds may be heard in rare
occasions. Such symptom is not a malfunction.
If the following problem occurs after the lamp is replaced, check the following fi rst.
Problem
The projector does not
turn on.
The STATUS indicator
blinks.
Solution
• Fit the lamp cover securely. (See pages 32 and 33.)
• Reset the lamp operating time. (See page 33.)
• Reset the lamp operating time. (See page 33.)
Kensington Lock
This projector has a Kensington Security Standard connector for use with Kensington MicroSaver Security System.
Refer to the information that came with the Kensington System for instructions on how to use it to secure the
projector. Please contact Kensington Technology Group below.
Kensington Technology Group
2855 Campus Drive
San Mateo, CA 94403, U.S.A.
Phone : +1- (650)572-2700
Fax : +1- (650)572-9675
Troubleshooting (continued)