19
18
OCH779
REFRIGERANT SYSTEM DIAGRAM
8
Unit: mm
SUZ-SM35VA.TH
Flared connection
Defrost
thermistor
RT61
Discharge
temperature
thermistor
RT62
Flared connection
Stop valve
(with strainer)
Stop valve
(with service port)
Refrigerant flow in cooling
Compressor
4-way valve
Refrigerant flow in heating
Refrigerant pipe ø9.52
(with heat insulator)
Refrigerant pipe ø6.35
(with heat insulator)
R.V. coil
heating ON
cooling OFF
Strainer
#100
Ambient
temperature
thermistor
RT65
Muffler
Capillary tube
ø3.0×ø2.0×240
Outdoor heat
exchanger
temperature
thermistor
RT68
Muffler
Outdoor
heat
exchanger
LEV
Strainer
#50
Outdoor
heat
exchanger
Flared connection
Defrost
thermistor
RT61
Discharge
temperature
thermistor
RT62
Flared connection
Stop valve
(with strainer)
Stop valve
(with service port)
Refrigerant flow in cooling
Compressor
4-way valve
Refrigerant flow in heating
Refrigerant pipe ø9.52
(with heat insulator)
Refrigerant pipe ø6.35
(with heat insulator)
R.V. coil
heating ON
cooling OFF
Strainer
#100
Capillary tube
ø3.0×ø2.0×210(×2)
LEV
Ambient
temperature
thermistor
Muffler
Capillary tube
ø4.0×ø2.4×240
Outdoor heat
exchanger
temperature
thermistor
Muffler
RT65
RT68
Strainer
#50
Unit: mm
SUZ-SM50VA.TH
Summary of Contents for SUZ-SM35VA
Page 15: ...15 OCH779 15 7 WIRING DIAGRAM SUZ SM35VA TH ...
Page 16: ...16 OCH779 SUZ SM50VA TH ...
Page 17: ...17 OCH779 SUZ SM60VA TH ...
Page 69: ...69 OCH779 ...