Outdoor unit model
SUZ-KA09
NAHZ
SUZ-KA12
NAHZ
SUZ-KA15
NAHZ
SUZ-KA18
NAHZ
Power supply
V , phase , Hz
208/230 , 1 , 60
Max. fuse size (time delay)
A
15
20
Min. circuit ampacity
A
14
17
Fan motor
F.L.A
0.67
1.00
Compressor
Model
SNB130FHBM2T
SNB220FQGMT
R.L.A
10.0
13.0
L.R.A
12.5
16.0
Refrigeration oil oz. (Model)
22.0
(FV50S)
23.7 (FV50S)
Refrigerant control
Linear expansion valve
Sound level
*
1
Cooling
dB(A)
54
55
Heating
dB(A)
55
Defrost method
Reverse cycle
Dimensions
W
in
33-1/16
D
in
13
H
in
34-5/8
Weight
Ib
129
131
External finish
Munsell 3Y 7.8/1.1
Control voltage (by built-in transformer)
VDC
12 - 24
Refrigerant piping
Not supplied
Refrigerant pipe size
(Min. wall thickness)
Liquid
in
1/4 (0.0265)
1/4 (0.0265)
Gas
in
3/8 (0.0285)
1/2 (0.0285)
Connection method Indoor
Flared
Outdoor
Flared
Between the indoor &
outdoor units
Height difference
ft
40
50
Piping length
ft
65
100
Refrigerant charge (R410A)
3 lb. 9 oz.
3 lb. 12 oz.
Note: Test conditions are based on AHRI 210/240.
Rating conditions (Cooling) — Indoor: 80˚F D.B., 67˚F W.B., Outdoor: 95˚F D.B., (75˚F W.B.)
(Heating) — Indoor: 70˚F D.B., 60˚F W.B., Outdoor: 47˚F D.B., 43˚F W.B.
3
SPECIFICATION
OPERATING RANGE
(1) POWER SUPPLY
Rated voltage
Guaranteed voltage (V)
Outdoor unit
208/230 V
1 phase
60 Hz
Min. 187
208
230 Max. 253