35
OPERATING PROCEDURE
PHOTOS
3. Removing the outdoor fan motor
(1) Remove the front panel. (Refer to 1)
(2) Unconnect the connector remove the clamp of fan motor
lead wire.
(3) Remove the propeller nut and remove the propeller fan.
(4) Remove screws fixing the fan motor.
4. Removing the compressor
(1) Remove the cabinet. (Refer to 1)
(2) Remove the relay panel.
(3) Remove the soundproof felt.
(4) Remove the terminal cover on the compressor.
(5) Disconnect lead wires from the glass terminal of the com-
pressor.
(6) Recover gas from the refrigerant circuit.
(7) Disconnect the welded part of the discharge pipe.
(8) Disconnect the welded part of the suction pipe.
(9) Remove nuts fixing the compressor.
(10) Remove the compressor.
NOTE
●
Before using a burner, recover gas from the pipes until the
pressure gauge shows 0 kg/cm
2
(0 MPa).
●
Use the burner under the condition that gas can be recovered
even when the inner pressure rises by heat.
Photo 5
Terminal cover
Compressor
Discharge pipe
Suction
pipe
Compressor nuts
Photo 4
propeller fan
Set screws for
outdoor fan motor
Outdoor
fan motor
Propeller
fan nut
OC282-A--2.qxp 03.1.28 4:30 PM Page 35