502
12 DATA USED FOR POSITIONING CONTROL
12.7 Monitor Data
[Md.500] Servo status7
• This area stores the servo status7.
Refresh cycle: Operation cycle
■
Reading the monitor value
• Monitoring is carried out with a hexadecimal display.
• Buffer memory address
Refer to the following for the buffer memory address in this area.
[Md.502] Driver operation alarm number
• This area stores the driver operation alarm number.
Refresh cycle: Immediate
■
Reading the monitor value
• Monitoring is carried out with a hexadecimal display.
Ex.
When the driver operation alarm is "10H" and the detailed number is "23H", "1023H" is displayed.
• Buffer memory address
Refer to the following for the buffer memory address in this area.
[Md.503] Pre-reading data analysis status
Use this monitor when using the pre-reading start function.
• This area stores the positioning data analysis status.
Refresh cycle: Operation cycle
■
Reading the monitor value
• Monitoring is carried out with a decimal display.
• Buffer memory address
Refer to the following for the buffer memory address in this area.
b15
b12
b8
b4
b0
Stored items
Meaning
0: OFF
1: ON
b9 Driver operation alarm
Monitor
value
Driver operation alarm
Detailed number
Pre-reading data analysis status
0: Standby
Monitor
value
1: Analyzing
2: Completed
Summary of Contents for RD77MS16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Application RD77MS2 RD77MS4 RD77MS8 RD77MS16 ...
Page 2: ......
Page 316: ...314 9 COMMON FUNCTIONS 9 4 External Input Signal Select Function Program example ...
Page 317: ...9 COMMON FUNCTIONS 9 4 External Input Signal Select Function 315 9 ...
Page 575: ...13 PROGRAMMING 13 4 Positioning Program Examples 573 13 Error reset program Axis stop program ...
Page 643: ......