47
OCH721A
1
2
3
4
5
6
M
Gray
Orange
Red
Yellow
Black
Parts name
Checkpoints
Disconnect the connector then measure the resistance with a tester.
(Ambient temperature 50 to 86°F [10 to 30°C])
Thermistor (TH3)
<Liquid>
Thermistor (TH4)
<Discharge>
Thermistor (TH6)
<2-phase pipe>
Thermistor (TH7)
<Ambient>
Thermistor (TH8)
<Heat sink>
Thermistor (TH33)
<Comp. surface>
Normal
160 to 410 k
Ω
4.3 to 9.6 k
Ω
39 to 105 k
Ω
TH4
TH33
TH3
TH6
TH7
TH8
Abnormal
Open or short
Measure the resistance between the terminals with a tester.
(Ambient temperature 68°F [20°C])
Solenoid valve coil
<4-way valve>
(21S4)
Motor for compressor
(MC)
Linear expansion valve
(LEV-A/LEV-B/LEV-C)
Normal
Abnormal
Open or short
Disconnect the connector then measure the resistance with a tester.
(Winding temperature 68°F [20°C])
Refer to the next page.
Fan motor(MF1)
1435
i
150
Ω
0.188
Ω
Measure the resistance between the terminals with a tester.
(Winding temperature 68°F [20°C])
Normal
Abnormal
Open or short
W
V
U
Normal
Gray - Black
Gray - Red
Gray - Yellow
Gray - Orange
Abnormal
46
i
3
Ω
Open or short
10-6. HOW TO CHECK THE PARTS
PUZ-HA24NHA