110
Compressor
(MC)
Valve bed
Separator
Separator
fixing screw
Power
receiver
Stop
valve
Stop valve
fixing screws
Ball valve
fixing screws
Valve
bed
fixing
screws
Valve
bed fixing
screw
Compressor
fixing nut
Receiver leg
fixing screws
Power
receiver
Receiver
leg
Inlet
Damper
Band
Outlet
Compressor
(MC)
10. Removing the compressor (MC)
(1) Remove the electrical parts box. (See Photo 4 or 5)
(2) Remove the cover panel (front). (See Photo1)
(3) Remove the cover panel (rear). (See Photo 1)
(4) Remove the ball valve fixing screws (2 for front/ 5x16).
(5) Remove the stop valve fixing screws (2 for front/ 5x16).
(6) Remove the valve bed. (See Photo 16)
(7) Remove the side panel (R). (See Photo 1)
(8) Remove the front panel fixing screws (5 for front/ 5x12 and 2
for front/ 4x10), then slide the front panel upward to remove it.
(The front panel is fixed with 4 hooks; 3 on the left side fixing
to the side panel (L), and the other on the right side fixing to
the separator.)
(9) Release the lead wire for FM1 and FM2 from the hole on
separator.
(10) Remove the separator fixing screws (4 for front/ 4x10),
then slide the separator upward to remove it.
(The separator is fixed to hooks of the side plate.)
(11) Remove the band and the damper. (See Figure 5)
(12) Recover refrigerant.
(13) Remove the welded part of compressor (2 positions).
(14)
Remove the 3 compressor fixing nuts (M6) to remove the
compressor.
Note 1: Recover refrigerant without spreading it in the air.
Note 2: The compressor can be easily removed by
removing separator.
Note 3: When replacing the compressor, ensure that
the surrounding parts are completely cold after
brazing, then fix the accessory damper with a
locally-procured band: Ensure to maintain at least
10 mm distance from the surrounding piping.
Photo 17
Photo 18
Figure 5
11. Removing the power receiver
(1) Remove the electrical parts box. (See photo 4 or 5)
(2) Remove the cover panel (front). (See Photo 1)
(3) Remove the cover panel (rear). (See Photo 1)
(4) Remove the ball valve fixing screws (See Photo 17).
(5) Remove the stop valve fixing screws (See Photo 17).
(6) Remove the valve bed. (See Photo 17)
(7) Remove the side panel (R). (See Photo 1)
(8) Recover refrigerant.
(9)
Remove the welded part of the power receiver to remove it.
(10) Remove the receiver leg fixing screws (2 for front /4 x 10),
then slide the power receiver forward to remove it.
(The power receiver is fixed to the base with a hook on
the bottom.)
Note: Recover refrigerant without spreading it in the air.
Ball
valve
OPERATING PROCEDURE
PHOTOS
OCH654