10
5
DATA
5-1. REFILLING REFRIGERANT CHARGE (R410A : kg)
5-2. COMPRESSOR TECHNICAL DATA
Piping length (one way)
10m
20m
30m
40m
50m
Factory
charged
2.1
2.1
3.1
3.1
4.6
4.6
4.6
2.3
2.3
3.3
3.3
4.8
4.8
4.8
2.5
2.5
3.5
3.5
5.0
5.0
5.0
2.7
2.7
4.1
4.1
5.6
5.6
5.6
2.9
2.9
4.7
4.7
6.2
6.2
6.2
60m
—
—
—
—
6.8
6.8
6.8
75m
—
—
—
—
7.4
7.4
7.4
2.5
2.5
3.5
3.5
5.0
5.0
5.0
Service Ref.
PUHZ-RP35VHA2
PUHZ-RP100VHA2
PUHZ-RP125VHA2
PUHZ-RP125YHA2
PUHZ-RP140VHA2
PUHZ-RP140YHA2
PUHZ-RP50VHA2
PUHZ-RP60VHA2
PUHZ-RP71VHA2
U-V
U-W
W-V
Unit
Compressor model
Winding
Resistance
(
"
)
ANV33FDDMT
(at 20
°
C)
0.266
0.266
0.266
SNB130FLBH
0.300 ~ 0.340
0.300 ~ 0.340
0.300 ~ 0.340
PUHZ-RP100VHA2
ANV33FDBMT
1.064
1.064
1.064
ANB33FDFMT
ANB33FCKMT
0.302
0.302
0.302
0.188
0.188
0.188
PUHZ-RP100YHA2
PUHZ-RP35/50VHA2
TNB220FMBH
0.865 ~ 0.895
0.865 ~ 0.895
0.865 ~ 0.895
PUHZ-RP60/71VHA2
PUHZ-RP125/140YHA2
PUHZ-RP125/140VHA2
Longer pipe than 30m, additional charge is
required.
OC374A--1.qxp 06.7.26 5:07 PM Page 10