70
1
2
3
4
5
6
M
Gray
Orange
Red
Yellow
Black
1
2
3
4
5
6
M
RP60/71/100/125/140
Parts name
Check points
Disconnect the connector then measure the resistance with a tester.
(At the ambient temperature 10
~30
)
Disconnect the connector then measure the resistance with a tester.
(Winding temperature 20
)
Thermistor (TH3)
<Outdoor pipe>
Thermistor (TH4)
<Discharge>
Thermistor (TH6)
<Outdoor 2-phase pipe>
Thermistor (TH7)
<Outdoor>
Thermistor (TH8)
<Heatsink>
Thermistor (TH32)
<Shell>
Thermistor (TH33)
<Outdoor pipe>
Normal
160k
~410k
4.3k
~9.6k
39k
~105k
TH4, TH32
TH3
TH6
TH7
TH33
TH8
Abnormal
Open or short
Normal
Red - White
Red - Orange
Brown - Yellow
Brown - Blue
Abnormal
46±4
Measure the resistance between the terminals with a tester.
(At the ambient temperature 20
)
Solenoid valve coil
<Four-way valve>
(21S4)
Motor for compressor
(MC)
Linear expansion valve
(LEV-A/ LEV-B)
For RP35-RP71
Linear expansion valve
(LEV-A/ LEV-B)
For RP100-RP140
Normal
Abnormal
Open or short
Abnormal
Open or short
Refer to 6-2.
RP35-71
Open or short
Disconnect the connector then measure the resistance with a tester.
(Winding temperature 20
)
Normal
Gray - Black
Gray - Red
Gray - Yellow
Gray - Orange
Abnormal
46±3
Open or short
Measure the resistance between the terminals with a tester.
(At the ambient temperature 20
)
Normal
Abnormal
Open
or
short
Solenoid valve coil
<Bypass valve>
(SV)
For RP60-RP140
Refer to next page.
Fan motor(MF1,MF2)
2350±170
Measure the resistance between the terminals with a tester.
(Winding temperature 20
)
Normal
W
V
U
Red
Brown
Blue
Orange
Yellow
White
RP100/125/140
1435±150
1197±10
11-6. HOW TO CHECK THE PARTS
PUHZ-RP35/50/60/71/100/125/140VHA2
(1)
PUHZ-RP125/140VHA2#2
PUHZ-RP100/125/140YHA2
(1)
PUHZ-RP125/140YHA2#2
PUHZ-RP35/50/60/71/100VHA3
PUHZ-RP60/71/100VHA3#1
PUHZ-RP100YHA3
PUHZ-RP100YHA3#1
Summary of Contents for PUHZ-RP100VHA3