7
Model name
Indoor unit
PLA-RP100BA
PLA-RP125BA
PLA-RP140BA
Outdoor unit
PUHZ-RP100YHA2
PUHZ-RP125YHA2
PUHZ-RP140YHA2
Cooling
Capacity
Btu/h
34,100
42,700
47,800
kW
10.0(4.9-11.4)
12.5(5.5-14.0)
14.0(5.5-15.3)
Total input
kW
3.02
3.87
4.65
EER
3.31
3.23
3.01
Energy label class
A
A
B
SHF
0.74
0.71
0.71
Heating
Capacity
Btu/h
38,200
47,800
54,600
kW
11.2(4.5-14.0)
14.0(5.0-16.0)
16.0(5.0-18.0)
Total input
kW
3.10
3.88
4.43
COP
3.61
3.61
3.61
Energy label class
A
A
A
Booster heater
kW
–
–
–
Power supply
Phase
[
3
Cycle
Hz
50
Voltage
V
400
Breaker size
A
16
Indoor unit
Air flow
CMM
20-23-26-30
22-25-28-31
(Low-Medium2-Medium1-High)
CFM
710-810-920-1060
780-880-990-1090
External pressure
Pa
0
0
Sound level
dB(A)
32-34-37-40
34-36-39-41
24-26-29-32
850-920-1020-1130
0
36-39-42-44
(Low-Medium2-Medium1-High)
External finish (Panel)
White Munsell 6.4Y 8.9/0.4
Dimension
W : mm
840 (950)
Unit (Panel)
D : mm
840 (950)
H : mm
298 (35)
W : inch
33-1/16 (37-3/8)
D : inch
33-1/16 (37-3/8)
H : inch
11-3/4 (1-3/8)
Weight
kg
27 (6)
Unit (Panel)
lbs
60 (13)
25 (6)
55 (13)
Field drain pipe O.D.
mm
32
inch
1-1/4
Outdoor unit
Air flow
CMM
100
CFM
3,530
Sound level at cooling
dB(A)
49
50
Sound level at heating
dB(A)
51
52
External finish
Ivory Munsell 3Y 7.8/1.1
Dimension
W : mm
950
D : mm
330+30
H : mm
1350
W : inch
37-3/8
D : inch
13 + 1-3/16
H : inch
53-1/8
Weight
kg
135
130
lbs
298
287
Refrigerant pipe size
Gas side O.D.
mm
15.88
inch
5/8
Liquid side O.D.
mm
9.52
inch
3/8
Refrigerant pipe length
Height difference
m
Max. 30
Length
m
Max. 75
NOTE:
1. Rating conditions (ISO T1)
Cooling Indoor : D.B. 27
:
(80˚F) W.B. 19
:
(66˚F)
Outdoor : D.B. 35
:
(95˚F) W.B. 24
:
(75˚F)
Heating Indoor : D.B. 20
:
(68˚F)
Outdoor : D.B. 7
:
(45˚F)
W.B. 6
:
(43˚F)
Refrigerant piping length (one way) : 5m (16ft.)
2. Guaranteed operating range
Indoor
Outdoor
Cooling
Upper limit D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C
Lower limit D.B. 19˚C, W.B. 15˚C
D.B. -5˚C
w
Heating
Upper limit D.B. 28˚C
D.B. 21˚C, W.B. 15˚C
Lower limit D.B. 17˚C
D.B. -20˚C, W.B. -20˚C
4. Above data are based on the indicated voltage.
Indoor unit
Single phase 230V 50Hz
3 phase 400V 50Hz
Outdoor unit
Indoor unit
198~264V, 50Hz
342~457V, 50Hz
Outdoor unit
3. Guaranteed voltage
w
If optional air protect guide installed. D.B.-15
:
OCS05E-1.qxp 08.3.31 9:52 AM Page 7
Summary of Contents for PUHZ-RP100VHA3
Page 52: ...52 WIRED REMOTE CONTROLLER Unit mm 130 120 19 43 5 ...
Page 53: ...53 WIRELESS REMOTE CONTROLLER Unit mm 159 3 55 58 19 ...
Page 98: ...98 9 3 PLA RP AA PLA RP AA2 9 3 1 Fresh air intake amount ...
Page 99: ...99 9 3 2 BRANCH DUCT Installation at site ...
Page 108: ...108 PEAD RP60GA PEAD RP71GA ...
Page 109: ...109 PEAD RP100GA ...
Page 116: ...116 ...