61
PEA-RP400, 500GA
GREEN/YELLOW
INDOOR UNIT
OUTDOOR UNIT
OUTDOOR UNIT
TAB1
TAB1
FAN
CNDK
31
1
5
73
X4
X5
X6
CN20
CN21
CN41
CN29
1
2
3
4
1
2
1
2
2
1
CN2D
CN90
CN22
CN2L
CND
CN32
CN31
CN51
1
2
3
4
5
FUSE
ZNR
31
31
1
2
DC13.1V
LED1
LED2
LED3
2
1
2
1
2
1
2
1
3
3
6
5
4
9
8
7
3
1
2
CN3C
3
1
CNSK
2
1
CN2S
DC
13.1V
3
1
CNSK
2
1
CN2S
DC
13.1V
CN2D
CN90
CN22
CN2L
FAN
CNDK
CND
CN32
CN31
CN51
1
2
3
4
5
FUSE
ZNR
31
31
31
1
2
DC13.1V
1
5
73
X4
X5
X6
LED1
LED2
LED3
2
1
2
1
2
1
2
1
3
3
6
5
4
9
8
7
3
1
2
CN3C
CN20
CN21
CN41
CN29
1
2
3
4
1
2
1
2
2
1
FB11
S1
1
2
REMOTE CONTROLLER
S2
S3
TB5
TB6
LCD
X1
FB21
S1
S2
S3
X2
TH1-1
TH2-1
TH5-1
TH5-2
TH2-2
TH1-2
TB4-2
TB4-1
FB12
FB22
X4
X5
X6
X4
X5
X6
51F
BLUE
POWER SUPPLY
3N~PE
380/400/415V
50Hz
CIRCUIT BREAKER
(FIELD SUPPLY)
PEA-RP400,500GA:15A
BLACK
WHITE
RED
DSR
DSA
N
BLACK
WHITE
RED
TB2
L3
L2
L1
PE
52F
C01
C02
1
2
3
MF1
1
2
3
52F
C01
5
4
X01
X02
49F
SWE
OFF
ON
345
SW1
OFF
ON
5
ON
OFF
34
12
2
1
SWE
OFF
ON
345
SW1
OFF
ON
5
ON
OFF
SW2
34
12
2
1
SW2
AUXILIARY RELAY
X4-6
MF1
51F
49F
TB2,4-1,4-2,5
TH1-1,1-2
TH2-1,2-2
FAN MOTOR (INDOOR)
OVER CURRENT RELAY (INDOOR FAN MOTOR)
INTERNAL THERMOSTAT (INDOOR FAN MOTOR)
TERMINAL BLOCK
THERMISTOR
INDOOR UNIT
FUSE
FUSE (T6.3AL250V)
ZNR
VARISTOR
TH5-1,5-2
CR
SURGE KILLER
MAGNETIC CONTACTOR (INDOOR FAN MOTOR)
52F
ROOM TEMP.
LIQUID PIPE TEMP.
COND./EVA. TEMP.
FERRITE CORE
FB11,FB12
FB21,FB22
INDOOR
CONTROLLER
BOARD
X1,2
AUXILIARY RELAY
NAME
SYMBOL
SNB
BOARD 1
ZNR5~7
VARISTOR
DSA,DSR
ARRESTER
SW2
SWE
LED1
LED (POWER SUPPLY)
LED2
LED (POWER SUPPLY<REMOTE CONTROLLER>)
LED3
LED (TRANSMISSION<INDOOR·OUTDOOR>)
SWITCH (MODEL SELECTION)
SW1
SWITCH (CAPACITY CORD)
CONNECTOR (EMERGENCY OPERATION)
OUTDOOR UNIT
TERMINAL BLOCK
NAME
SYMBOL
TB3,TB8
CN2L
CN31
CN90
CN51
CN41
CN32
CONNECTOR (DRAIN SENSOR)
CONNECTOR (REMOTE SWITCH)
CONNECTOR (HA TERMINAL-A)
CONNECTOR (CENTRALLY CONTROL)
CONNECTOR (WIRELESS REMOTE CONTROLLER)
CONNECTOR (LOSSNAY)
REMOTE CONTROLLER
TERMINAL BLOCK
NAME
SYMBOL
TB6
4. Indoor and outdoor connecting wires have polarities, make sure to
match wiring and terminal.
5. Emergency operation
If a trouble occurs with either the remote controller or the indoor microcom-
puter and no other trouble exists, emergency operation for cooling or heating
can be performed by changing the setting of connector (SWE) "ON" on the
indoor controller board.
SWE :ON / Indoor fan is running at high speed.
(No.2)
INDOOR
CONTROLLER
BOARD
(No.1)
REMOTE CONTROLLER BOARD
INDOOR POWER BOARD
(No.1)
(No.2)
INDOOR
CONTROLLER
BOARD
(No.2)
TO OUTDOOR UNIT
CONNECTING WIRES
(POLAR)
TO OUTDOOR UNIT
CONNECTING WIRES
(POLAR)
SNB BOARD 1
(No.1)
INDOOR POWER BOARD
Note:1. The dotted lines show field wiring.
2. Color of earth wire is yellow and green twisting.
3. Specification subject to change without notice.
51F
6. mark is connector. mark is terminal.
Caution,
1.To protect fan motor from abnormal current, overcurrent relays are installed.
Therefore, do not change factory set value of overcurrent relays.
CR
ZNR5~7
OCS05E-2.qxp 08.3.31 10:21 AM Page 61
Summary of Contents for PUHZ-RP100VHA3
Page 52: ...52 WIRED REMOTE CONTROLLER Unit mm 130 120 19 43 5 ...
Page 53: ...53 WIRELESS REMOTE CONTROLLER Unit mm 159 3 55 58 19 ...
Page 98: ...98 9 3 PLA RP AA PLA RP AA2 9 3 1 Fresh air intake amount ...
Page 99: ...99 9 3 2 BRANCH DUCT Installation at site ...
Page 108: ...108 PEAD RP60GA PEAD RP71GA ...
Page 109: ...109 PEAD RP100GA ...
Page 116: ...116 ...