7. Installation and transferring works, and checking

Regarding place for installation

Consult with your dealer for details on installation and transferring the installation.

Caution:

Never install the air conditioner where there is a risk of leakage of flammable
gas.
If gas leaks and accumulates around the unit, fire can result.

Never install the air conditioner at the following place:

where there is much machine oil

near ocean and beach areas where there is much salt

where humidity is high

where there are hot springs nearby

where there is much sulfureted gas

where there is a high-frequency processing machinery (a high-frequency welder,
etc.)

where acid solution is frequently used

where special sprays are frequently used

Install the unit horizontally. Otherwise, water leakage can result.

Take sufficient measures against noise when installing the air conditioners at
hospitals or communication-related businesses.

If the air conditioner is used in any of the above-mentioned environments, frequent
operational failure can be expected. It is advisable to avoid these types of installa-
tion sites.
For further details, consult with your dealer.

Regarding electrical work

Caution:

The electrical work must be undertaken by a person who is qualified as
an electric engineer according to the [technical standard respecting elec-
trical installation], [internal wiring rules], and the installation instruction
manual with the absolute use of exclusive circuits. The use of other prod-
ucts with the power source can result in burnt-out beakers and fuses.

Never connect the grounding wire to a gas pipe, water pipe, arrester, or
telephone grounding wire. For details, consult with your dealer.

In some types of installation sites, the installation of an earth leakage
breaker is mandatory. For details, consult with your dealer.

Regarding transfer of installation

When removing and reinstalling the air conditioner when you enlarge your
home, remodel, or move, consult with your dealer in advance to ascertain the
cost of the professional engineering work required for transferring the installa-
tion.

Caution:

When moving or reinstalling the air conditioner, consult with your dealer.
Defective installation can result in electric shock, fire, etc.

Regarding noise

In installing work, choose a place that can fully bear the weight of the air con-
ditioner, and where noise and vibration can be reduced.

Choose a place where cool or warm air and noise from the outdoor air outlet of
the air conditioner do not inconvenience the neighbors.

If any alien object is placed near the outdoor air outlet of the air conditioner,
decreased performance and increased noise can result. Avoid placing any
obstacles adjacent to the air outlet.

If the air conditioner produces any abnormal sound, consult with your dealer.

Maintenance and inspection

If the air conditioner is used throughout several seasons, the insides can get
dirty, reducing the performance.

Depending upon the conditions of usage, foul odors can be generated and
drainage can deteriorate due to dust and dirt, etc.

The unit started even though the start/stop button was not pushed.

• Is the timer on?

Press the start/stop button to stop the unit.

• Was a distant command sent from the remote controller?

Find out if the remote controller was used.

• Is the CENTRALLY CONTROLLED message lit?

Find out if the remote controller was used.

• Is the automatic (cooling/heating) mode selected?

Press the start/stop button to stop the unit.

The unit stopped even though the start/stop button was not pushed.

• Is the timer on?

Press the start/stop button to restart the unit.

• Was a distant command sent from the remote controller?

Find out if the remote controller was used.

• Is the CENTRALLY CONTROLLED message lit?

Find out if the remote controller was used.

The remote controller’s timer cannot be set.

• Set the schedule timer if one is connected.

“HO” is displayed in the remote controller.

• An automatic startup test is being performed (will last for about two minutes).

An error code is displayed in the remote controller.

• A self-diagnostic function is being performed to preserve the air conditioner.

* Do not attempt to make repairs yourself. Turn the main switch off and

contact the dealer from whom you bought the air conditioner. Provide him
or her with the name of the unit and the information displayed in the re-
mote controller.

The fan in the unit does not operate.

• Check the over-current relay on the fan motor to determine whether it has

been tripped.
If the over-current relay has been tripped, reset it after eliminating the cause
of the problem (e.g. motor lock).
To reset the over-current relay, open the control box and press the green
claw on bottom-right of the relay until a click is heard. Release the claw and
check that it returns to its original position.
Note that if it is pressed too hard it will not return to its original position.

NOTE:
The following do not indicate any malfunction:

Odours: smells such as tobacco or cosmetic odours may persist after they have
been sucked into the unit.
Sound of liquid flowing inside air inlet and outlet part: this can occur during or after
operation and is simply the sound of refrigerant being circulated inside the unit.
Ticking sound coming from air inlet and outlet part: this can occur when cooling or
heating has just begun or has just stopped. It is caused by the indoor unit shrinking
or expanding slightly due to the change in temperature.
The message “CENTRALLY CONTROLLED” appearing on the LCD panel: from
time to time, this message may come up on the LCD panel. This does not indicate
any malfunction.

Summary of Contents for PRH-P10MYA

Page 1: ...IONES Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado para garantizar un uso seguro y correcto ISTRUZIONI DI FUNZIONAMENTO Leggere attentamente questi istruzioni di funzionamento prima di avviare l unità per un uso corretto e sicuro della stessa BEDIENINGSHANDLEIDING Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig ...

Page 2: ...f top flow A Return air B Supply air C Outdoor heat exchanger air inlet D Outdoor heat exchanger air outlet E Fresh air intake Fig 2 0 2 A Remote controller ON OFF TEMP A A D B C E E C D C C A E E B A PRH P8 10MYA PRH P16 20MYA B A B A D D C E E C C A D D C E E C C B B ...

Page 3: ...ting the unit make sure you read all the Safety precautions s Safety precautions lists important points about safety Please be sure to follow them Symbols used in the text Warning Describes precautions that should be observed to avoid the risk of injury or death to the user Caution Describes precautions that should be observed to prevent damage to the unit Symbols used in the illustrations Indicat...

Page 4: ...any repair serv ice Improper repair work can result in water leakage electric shock fire etc If the remote controller displays an error indication the air conditioner does not run or there is any abnormality stop operation and contact your dealer Leaving the unit as it is under such conditions can result in fire or failure If the power breaker is frequently activated get in touch with your dealer ...

Page 5: ...nt warm air blows out Caution When the air conditioner is used together with burners thoroughly ven tilate the area Insufficient ventilation can result in accidents due to oxy gen deficiency Never place a burner at a place where it is exposed to the airflow from the air conditioner Doing so can result in imperfect combustion of the burner The microcomputer functions in the following cases Air does...

Page 6: ...cted to a power stop of the air conditioner or a power failure 3 6 Timer setting If the timer is set the unit starts stops at the set time and the time mode is terminated When you wish to confirm the starting and ending time press the 4 time selection button while C is displayed Function of timer On timer Set the on timer for the time the working day begins in your company When the set start time ...

Page 7: ...shock or fire 3 7 Others CENTRALLY CONTROLLED Displayed when control is executed by a separately sold centralized control unit etc STAND BY DEFROST Displayed from the start of heating operation until the moment warm air blows out CHECK This displays indication when some abnormality oc curs in the unit NOT AVAILABLE When a button is pressed for any function which the indoor unit cannot perform this...

Page 8: ...bstacles adjacent to the air outlet If the air conditioner produces any abnormal sound consult with your dealer Maintenance and inspection If the air conditioner is used throughout several seasons the insides can get dirty reducing the performance Depending upon the conditions of usage foul odors can be generated and drainage can deteriorate due to dust and dirt etc The unit started even though th...

Page 9: ...the product nameplate attached to the unit for the electrical specifications 2 Rating conditions cooling Indoor 27 C DB 19 C WB Outdoor 35 C DB 24 C WB 3 Rating conditions heating Indoor 20 C DB Outdoor 7 C DB 6 C WB Operating range Units should be installed by licensed electric contractor accordingly to local code requirement Cooling Heating Maximum Minimum Maximum Minimum Indoor air intake tempe...

Page 10: ...he contact address telephone number on this manual before handing it to the customer The product at hand is based on the following EU regulations Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directive 89 336 EEC This product is designed and intended for use in the residential commer cial and light industrial environment ...

Page 11: ......

Reviews: