4. Removing the room temperature thermistor (TH1)
(1) Remove the electrical box cover. (See Photo 1 and 2)
(2) Disconnect the connector CN20 (Red) from the indoor
controller board.
(3) Remove the room temperature thermistor with its
holder. (See Photo 3)
Electrical box
fixing screw
(M5×10)
Electrical box
fixing screw
(M5×10)
Thermistor holder
Thermistor (TH1)
5. Removing the indoor controller board (I.B)
(1) Remove the electrical box cover. (See Photo 1 and 2)
(2) Disconnect the connectors:
CNMF (White) for fan motor
CNV (White) for vane motor
CN5Y (White) for motor for i-see Sensor (Option)
CN4Z (White) for sensor for i-see Sensor (Option)
CN90 (White) for signal receiver (Option)
CNP (White) for drain pump
CN4F (White) for float switch
CN44 (White) for thermistor (TH2/TH5)
CN01 (Black) for Indoor/Outdoor connecting line
CN3C (Blue) for Indoor/Outdoor transmission
Disconnect the connectors for optional parts, if any.
(3) For the unit controlled with the wireless remote control
-
ler, disconnect the lead wire connected to TB5 on the
indoor controller board.
TB5: Remote controller transmission connecting wire
(4) Remove the indoor controller board (3 holders/4 Hooks).
(See Photo 4)
Holders
Hooks