1. SPECIFICATIONS
6
MEE16K008_U
Model
PLFY-EP24NEMU-E
PLFY-EP30NEMU-E
PLFY-EP36NEMU-E
PLFY-EP48NEMU-E
Power source
1-phase 208-230 V 60Hz
Cooling capacity
*1 BTU/h
24,000
30,000
36,000
48,000
*1 kW
7.0
8.8
10.6
14.1
Power input
kW
0.04
0.04
0.07
0.11
Current input
A
0.43
0.45
0.73
1.01
Heating capacity
*2 BTU/h
27,000
34,000
40,000
54,000
*2 kW
7.9
10.0
11.7
15.8
Power input
kW
0.04
0.04
0.07
0.11
Current input
A
0.38
0.40
0.68
0.96
External finish
Galvanized steel sheet
External dimension H × W × D
inch
11-3/4 × 33-3/32 × 33-3/32
11-3/4 × 33-3/32 × 33-3/32
11-3/4 × 33-3/32 × 33-3/32
11-3/4 × 33-3/32 × 33-3/32
mm
298 × 840 × 840
298 × 840 × 840
298 × 840 × 840
298 × 840 × 840
Net weight
lbs (kg)
55 (25)
55 (25)
55 (25)
55 (25)
Decoration panel
Model
PLP-40EAEU
PLP-40EAEU
PLP-40EAEU
PLP-40EAEU
External finish
MUNSELL (6.4Y 8.9/0.4)
Dimension
in.
1-9/16 × 37-3/8 × 37-3/8
1-9/16 × 37-3/8 × 37-3/8
1-9/16 × 37-3/8 × 37-3/8
1-9/16 × 37-3/8 × 37-3/8
H × W × D
mm
40 × 950 × 950
40 × 950 × 950
40 × 950 × 950
40 × 950 × 950
Net weight
lbs (kg)
11 (5)
11 (5)
11 (5)
11 (5)
Heat exchanger
Cross fin
FAN
Type × Quantity
Turbo fan × 1
Turbo fan × 1
Turbo fan × 1
Turbo fan × 1
External static press.
in.WG
0.000 (208V)
0.000 (208V)
0.000 (208V)
0.000 (208V)
Pa
0
0
0
0
in.WG
0.000 (230V)
0.000 (230V)
0.000 (230V)
0.000 (230V)
Pa
0
0
0
0
Motor Type
DC motor
Motor output
kW
0.12
0.12
0.12
0.12
Driving mechanism
Direct-driven
Air flow rate
(Low-Mid2-Mid1-High)
(Low-Mid2-Mid1-High)
(Low-Mid2-Mid1-High)
(Low-Mid2-Mid1-High)
cfm
636 - 671 - 742 - 812
636 - 706 - 777 - 812
777 - 883 - 989 - 1,095
777 - 953 - 1,095 - 1,236
m
3
/min
18 - 19 - 21 - 23
18 - 20 - 22 - 23
22 - 25 - 28 - 31
22 - 27 - 31 - 35
L/s
300 - 317 - 350 - 383
300 - 333 - 367 - 383
367 - 417 - 467 - 517
367 - 450 - 517 - 583
Sound pressure level (measured in anechoic room)
(Low-Mid2-Mid1-High)
(Low-Mid2-Mid1-High)
(Low-Mid2-Mid1-High)
(Low-Mid2-Mid1-High)
dB <A>
28 - 30 - 32 - 34
28 - 31 - 33 - 35
35 - 37 - 39 - 41
36 - 39 - 42 - 45
Insulation material
PS
Air filter
PP honeycomb (long life filter, anti-bacterial type)
Protection device
Fuse
Refrigerant control device
LEV
Connectable outdoor unit
R410A CITY MULTI
Refrigerant piping
Liquid (R410A)
inch (mm)
3/8 (9.52) Flare
3/8 (9.52) Flare
3/8 (9.52) Flare
3/8 (9.52) Flare
diameter
Gas (R410A)
inch (mm)
5/8 (15.88) Flare
5/8 (15.88) Flare
5/8 (15.88) Flare
5/8 (15.88) Flare
Field drain pipe size
inch (mm)
O.D. 1-1/4(32)
O.D. 1-1/4(32)
O.D. 1-1/4(32)
O.D. 1-1/4(32)
Drawing
External
BK01V542
BK01V542
BK01V542
BK01V542
Wiring
RG79Y808
RG79Y808
RG79Y808
RG79Y808
Refrigerant cycle
-
-
-
-
Standard attachment
Document
Installation Manual, Instruction Book
Accessory
Optional parts
Grille with 3D i-see Sensor
PLP-40EAEU
PLP-40EAEU
PLP-40EAEU
PLP-40EAEU
Air outlet shutter plate
PAC-SJ37SP-E
PAC-SJ37SP-E
PAC-SJ37SP-E
PAC-SJ37SP-E
High efficiency filter element
PAC-SH59KF-E
PAC-SH59KF-E
PAC-SH59KF-E
PAC-SH59KF-E
Multi-function casement
PAC-SJ41TM-E
PAC-SJ41TM-E
PAC-SJ41TM-E
PAC-SJ41TM-E
Remarks
* Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be re-
ferred to the Installation Manual.
* Due to continuing improvement, above specification may be subject to change without notice.
Notes :
*1 Nominal cooling conditions
*2 Nominal heating conditions
Unit converter
Indoor: 80degF D.B. / 67degF W.B.
70degF D.B.
kcal/h = kW x 860
(26.7degC D.B. / 19.4degC W.B.)
(21.1degC D.B.)
BTU/h = kW x 3,412
Outdoor: 95degF D.B.
47degF D.B. / 43degF W.B.
cfm = m
3
/min x 35.31
(35degC D.B.)
(8.3degC D.B. / 6.1degC W.B.)
lbs = kg / 0.4536
Pipe length: 25 ft. (7.6 m)
25 ft. (7.6 m)
Level difference: 0 ft. (0 m)
0 ft. (0 m)
*Above specification data is
subject to rounding variation.
0000004082.BOOK 6 ページ 2016年9月8日 木曜日 午後2時43分