4. ELECTRICAL WIRING DIAGRAMS

MEE16K008_U

4. ELECTRICAL WIRING DIAGRAMS

PLFY-P08,12,15 NCMU-E

DP

 WHT

(DRAIN)

 WHT

FAN

(FAN)

See fig:   1

MODELS

P08

P12

P15

<fig:   1>

ON

OFF

1 2 3 4 5 6

ON

OFF

1 2 3 4 5 6

ON

OFF

1 2 3 4 5 6

SW2

Power supply for MA-Remote controller on     Lamp is lit.

Main power supply(Indoor unit:208-230V) power on     Lamp is lit.

Main power supply

LED2

LED1

Mark

Meaning

LED on indoor controller board for service

Function

CN32

(REMO

TE SWITCH)  WHT

321

DC24-30V

CONTROLLER

60Hz

HA

1

2

3

4

 WHT

CN41

CN51

 WHT

(CENTRALLY

 CONTROL)

5 4 3 2 1

CN52

(REMOTE 

 INDICATION)

 GRN

1

2

3

4

5

REMOTE SWITCH

CN32

X7

FAN MOTOR (Me)

X6

FAN MOTOR (Hi)

X5

FAN MOTOR (Lo)

SW1

SWITCH

MODE SELECTION

CONNECTION No.

SW14

SW12

SW11

ADDRESS SETTING 1ST DIGIT

ADDRESS SETTING 2ND DIGIT

MODEL SELECTION

MODE SELECTION

CAPACITY CODE

SW4

SW3

SW2

(32 F/15k   77 F/5.4k  )

(32 F/15k   77 F/5.4k  )

DP

DRAIN PUMP

DS

DRAIN SENSOR

H2

DEW PREVENTION HEATER

FAN MOTOR (LL)

DRAIN PUMP/DEW PREVENTION HEATER

X1

AUX. RELAY

SYMBOL

NAME

VARISTOR

INDOOR POWER BOARD

P.B

ZNR

X4

I.B

CN41

CN51

CN52

FUSE

FUSE (6.3A/250V)

REMOTE INDICATION

CENTRALLY CONTROL

HA TERMINAL-A

CONNECTOR

INDOOR CONTROLLER BOARD

[LEGEND]

NAME

SYMBOL

PIPE TEMPERATURE DETECTION/GAS

TH23

TRANSMISSION

TERMINAL

BLOCK

POWER SUPPLY

TB5

TB15

TB2

(32 F/15k   77 F/5.4k  )

THERMISTOR ROOM TEMPERATURE DETECTION

TH22

TH21

LEV

LINEAR EXPANSION VALVE

MV

MF

VANE MOTOR

FAN MOTOR (WITH THERMAL FUSE)

CAPACITOR (FAN MOTOR)

C1

PIPE TEMPERATURE DETECTION/LIQUID

MA-REMOTE CONTROLLER

LED2

LED1

3

1

1 3

CND

(POWER)

YL

W

2

1

YL

W

1 3

 BLU

(D+U+M)

CNC

(D+HEATER)

 RED

 ORN

FUSE

ZNR

CNP

X1

RED

ORN

GRILLE

BLU

5

WHT
BLU

RED
ORN
YLW

RED

RED

1

10

7

2

3

6

4

5

8

9

3

5

5

5

5

C1

1

5

BLK

YL

W

 WHT

BRN

7 9

X6 X5 X4

X7

X4

X7

X5

X6

MF

I.B

CN20

CN31

1

2

3

BLU

WHT

ORN

RED

YL

W

6

6 5 4 3 2 1

(VANE)

CN6V

 GRN

RED

ORN

BLU

6 5 4 3 2 1

(LEV)

CN60

 WHT

WHT

YL

W

BRN

 BLK

2

2 1

1

(LIQUID)

(INTAKE)

CN21

 RED

 WHT

2 1

(GAS)

CN29

(REMOCON)

WHT

1

3

RED

P.B

 RED

CNDK

(POWER 

 BORD)

1

2

3

AC208-230V

CNSK(RED)

TB2

L1
L2
GR

RED
BLU

GRN/YLW

AC 208/230V 

POWER SUPPLY

TRANS

DC13.1V

CN2S(WHT)

2

1

21

(PO

WER 

 BORD)

CN2D

WHT

 WHT

 BLK

M1

1

2

CONTROLLER

DC8.7-13V

TO MA-REMOTE

CN2M

(M-NET)

1
2

31

CN3A

BLU

BLU

M2

TB15

S(SHIELD)

M-NET REMOTE 

TO OUTDOOR UNIT

BC CONTROLLER

TB5

X1

TH23

TH22

TH21

DS

LEV

5

3RD

DIGIT

0

O

0

0N

0FF

SW1

1 2 3 4 5 6 7 8 9 10

SW12

SW11

1ST

DIGIT

0

2ND

DIGIT

SW14

CONNECTION

No.

1 2 3 4 5

0FF

0N

SW4

SW2

6

5

4

3

2

1

10

9

8

7

6

5

4

3

2

1

0FF

0N

SW3

MV

H2

MV

MV

MV

Notes:

2.In case of using MA-Remote controller, please connect to TB15. (Remote controller wire is non-polar.)
3.In case of using M-NET, please connect to TB5. (Transmisson line is non-polar.)
4.Symbol[S] of TB5 is the shield wire connection.
5.Symbols used in wiring diagram above are,       :terminal block,         :connecter.

7.Use copper supply wire.

6.The setting of the SW2 dip switches differs in the capacity for the detail, refer to the fig:1.

1.At servicing for outdoor unit, always follow the wiring diagram of outdoor unit.

Power supply for

MA-Remote controller

0000004082.BOOK  13 ページ  2016年9月8日 木曜日 午後2時43分

Summary of Contents for PLFY-(E)P-NEMU-E

Page 1: ...MODEL PLFY P NCMU E PLFY E P NEMU E NEW AIR CONDITIONING SYSTEMS ...

Page 2: ...1 CITY MULTI MEE16K008_U 1 INDOOR UNITS Ceiling cassette 4 way flow type 3 PLFY P NCMU E PLFY E P NEMU E ELECTRICAL CHARACTERISTICS 31 ...

Page 3: ...2 MEE16K008_U ...

Page 4: ...vels 16 5 2 NC curves 16 6 TEMPERATURE AIRFLOW DISTRIBUTIONS 18 6 1 Temperature distributions 18 6 2 Airflow distributions 21 7 OUTDOOR AIR INTAKE AMOUNT STATIC PRESSURE 24 8 OPTIONAL PARTS 27 8 1 Optional parts line up for the Indoor unit 27 8 2 Air outlet shutter plate 27 8 3 High efficiency filter element 28 8 4 Multi function casement 28 8 5 Wireless signal receiver 29 8 6 Flange for fresh air...

Page 5: ... 150 167 183 150 167 183 Sound pressure level Low Mid High dB A 29 32 38 208 230V 30 34 39 208 230V 31 35 40 208 230V measured in anechoic room dB A dB A Insulation material Polyethylene foam Air filter PP honey comb fabric Protection device Fuse Refrigerant control device LEV Connectable outdoor unit R410A CITY MULTI Diameter of refrigerant pipe O D Liquid R410A in mm 1 4 6 35 Flare 1 4 6 35 Flar...

Page 6: ...vel measured in anechoic room Low Mid2 Mid1 High Low Mid2 Mid1 High Low Mid2 Mid1 High Low Mid2 Mid1 High dB A 27 29 30 31 27 29 30 31 28 29 30 31 28 30 31 32 Insulation material PS Air filter PP honeycomb long life filter anti bacterial type Protection device Fuse Refrigerant control device LEV Connectable outdoor unit R410A CITY MULTI Refrigerant piping Liquid R410A inch mm 1 4 6 35 Flare 1 4 6 ...

Page 7: ...evel measured in anechoic room Low Mid2 Mid1 High Low Mid2 Mid1 High Low Mid2 Mid1 High Low Mid2 Mid1 High dB A 28 30 32 34 28 31 33 35 35 37 39 41 36 39 42 45 Insulation material PS Air filter PP honeycomb long life filter anti bacterial type Protection device Fuse Refrigerant control device LEV Connectable outdoor unit R410A CITY MULTI Refrigerant piping Liquid R410A inch mm 3 8 9 52 Flare 3 8 9...

Page 8: ...sure level measured in anechoic room Low Mid2 Mid1 High Low Mid2 Mid1 High Low Mid2 Mid1 High Low Mid2 Mid1 High dB A 27 29 30 31 27 29 30 31 28 29 30 31 28 30 31 32 Insulation material PS Air filter PP honeycomb long life filter anti bacterial type Protection device Fuse Refrigerant control device LEV Connectable outdoor unit R410A CITY MULTI Refrigerant piping Liquid R410A inch mm 1 4 6 35 Flare...

Page 9: ... pressure level measured in anechoic room Low Mid2 Mid1 High Low Mid2 Mid1 High Low Mid2 Mid1 High Low Mid2 Mid1 High dB A 28 31 34 37 28 32 35 38 35 38 41 44 36 39 42 45 Insulation material PS Air filter PP honeycomb long life filter anti bacterial type Protection device Fuse Refrigerant control device LEV Connectable outdoor unit R410A CITY MULTI Refrigerant piping Liquid R410A inch mm 3 8 9 52 ...

Page 10: ... O D 1 1 4 32 Vane motor Drain hole Models Air intake grille 2 5 32 55 1 3 8 35 1 3 8 35 2 5 32 55 Auto vane Grille Air intake hole Air intake hole Air outlet hole Air outlet hole 11 27 32 301 11 27 32 301 14 27 32 377 14 27 32 377 25 19 32 650 Suspension bolt M10 or W3 8 Suspension bolt lower edge 9 1 16 230 7 5 32 182 1 7 8 48 Wiring entry Terminal block Ceiling surface 9 1 4 235 8 3 16 208 7 19...

Page 11: ...TO SOCKET OR ATTACHED FLEXIBLE HOSE CONNECTING BY VINYL CHLORIDE SERIES ADHESIVE THE BOTTOM OF SUSPENSION BOLT THE BOTTOM OF MOVE EYE SENSOR 17 5 0 0 3 16 2 9 32 58 1 31 32 TO 2 3 4 50 70 5 1 2 140 6 11 16 170 4 1 8 105 7 15 32 190 21 32 A 1 9 16 40 B 2 3 8 60 24 23 32 628 GRILLE CEILING ø6 7 8 ø175 BURRING HOLE PITCH SELF TAP 4 SCREWS 4 PLACES BRANCH DUCT HOLE ø5 29 32 ø150 CUTTING OUT HOLE BRANC...

Page 12: ...LE DRAIN PIPE CONNECT TO VP 25 CEILING CONNECTING TO SOCKET OR ATTACHED FLEXIBLE HOSE CONNECTING BY VINYL CHLORIDE SERIES ADHESIVE THE BOTTOM OF SUSPENSION BOLT THE BOTTOM OF MOVE EYE SENSOR 17 5 0 0 3 16 2 9 32 58 1 31 32 TO 2 3 4 50 70 5 1 2 140 6 11 16 170 4 1 8 105 7 15 32 190 21 32 A 1 9 16 40 B 2 3 8 60 24 23 32 628 GRILLE CEILING ø6 7 8 ø175 BURRING HOLE PITCH SELF TAP 4 SCREWS 4 PLACES BRA...

Page 13: ... 16 100 3 15 16 100 3 15 16 100 3 15 16 PLFY EP08NEMU E PLFY EP12NEMU E PLFY EP15NEMU E PLFY EP18NEMU E PLFY EP24NEMU E PLFY EP30NEMU E PLFY EP36NEMU E PLFY EP48NEMU E X Y Z mm in Model name 325 12 13 16 325 12 13 16 325 12 13 16 325 12 13 16 325 12 13 16 325 12 13 16 325 12 13 16 325 12 13 16 390 15 3 8 390 15 3 8 390 15 3 8 390 15 3 8 390 15 3 8 390 15 3 8 380 14 31 32 380 14 31 32 115 4 17 32 1...

Page 14: ...ERMAL FUSE CAPACITOR FAN MOTOR C1 PIPE TEMPERATURE DETECTION LIQUID MA REMOTE CONTROLLER LED2 LED1 3 1 1 3 CND POWER YLW 2 1 YLW 1 3 BLU D U M CNC D HEATER RED ORN FUSE ZNR CNP X1 RED ORN GRILLE BLU 5 WHT BLU RED ORN YLW RED RED 1 10 7 2 3 6 4 5 8 9 3 5 5 5 5 C1 1 5 BLK YLW WHT BRN 7 9 X6 X5 X4 X7 X4 X7 X5 X6 MF I B CN20 CN31 1 2 3 BLU WHT ORN RED YLW 6 6 5 4 3 2 1 VANE CN6V GRN RED ORN BLU 6 5 4 ...

Page 15: ...turn off the indoor and the outdoor units before replacing indoor controller board 8 is the switch position 1 Use copper supply wires 1 Utilisez des fils d alimentation en cuivre CN27 CN32 CN51 CN52 SW2 SW3 SW4 F1 MF MV DP FS TB2 TB5 TB15 TH22 TH23 LEV W B RU BZ LED1 LED2 SW1 SW2 POWER SUPPLY TRANSMISSION MA REMOTE CONTROLLER PIPE TEMP DETECTION LIQUID 32ºF 15kΩ 77ºF 5 4kΩ PIPE TEMP DETECTION GAS ...

Page 16: ... turn off the indoor and the outdoor units before replacing indoor controller board 8 is the switch position 1 Use copper supply wires 1 Utilisez des fils d alimentation en cuivre CN27 CN32 CN51 CN52 SW2 SW3 SW4 F1 MF MV DP FS TB2 TB5 TB15 TH22 TH23 LEV W B RU BZ LED1 LED2 SW1 SW2 POWER SUPPLY TRANSMISSION MA REMOTE CONTROLLER PIPE TEMP DETECTION LIQUID 32ºF 15kΩ 77ºF 5 4kΩ PIPE TEMP DETECTION GAS...

Page 17: ...ximate minimum audible limit on continuous noise NC 40 NC 30 NC 20 High Middle 60Hz Middle2 60Hz Low 60Hz 60Hz 63 125 250 500 1k 2k 4k 8k Octave band center frequencies Hz PLFY EP08 12NEMU E External Static Pressure 0Pa 0 00in WG Power Source 208 230V 60Hz 10 0 15 0 20 0 25 0 30 0 35 0 40 0 45 0 50 0 55 0 60 0 65 0 70 0 NC 60 NC 50 Octave band pressure level dB 0dB 20μPa Approximate minimum audibl...

Page 18: ...NC 50 Octave band pressure level dB 0dB 20μPa Approximate minimum audible limit on continuous noise NC 40 NC 30 NC 20 High Middle 60Hz Middle2 60Hz Low 60Hz 60Hz 63 125 250 500 1k 2k 4k 8k Octave band center frequencies Hz PLFY P18NEMU E External Static Pressure 0Pa 0 00in WG Power Source 208 230V 60Hz 10 0 15 0 20 0 25 0 30 0 35 0 40 0 45 0 50 0 55 0 60 0 65 0 70 0 NC 60 NC 50 Octave band pressur...

Page 19: ...distributions PLFY P08 12 15 NCMU E 2 7 8 9 Height m ft Floor distance m ft 2 6 6 1 3 3 3 9 8 2 6 6 1 3 3 0 0 21 70 23 73 25 77 25 77 Floor distance m ft 0 0 35 95 27 81 23 73 23 73 31 88 19 66 C F 3 9 8 2 6 6 1 3 3 2 7 8 9 Height m ft 2 6 6 1 3 3 Heating mode Flow angle 70 Cooling mode Flow angle 30 C F ...

Page 20: ... 7 8 9 23 73 23 73 Height m ft Floor distance m ft C F 27 81 27 81 27 81 27 81 25 77 25 77 1 0 3 3 0 2 5 8 2 2 6 6 1 3 3 1 3 3 0 2 6 6 2 5 8 2 2 0 6 6 2 7 8 9 Height m ft Floor distance m ft C F 28 82 24 75 26 79 24 75 30 86 30 86 30 86 28 82 24 75 26 79 24 75 30 86 30 86 30 86 Height m ft Floor distance m ft C F 1 0 3 3 0 3 9 9 2 6 6 1 3 3 0 1 3 3 2 6 6 3 9 9 2 0 6 6 2 7 8 9 27 81 27 81 27 81 27 ...

Page 21: ...t m ft C F 1 0 3 3 0 2 0 6 6 2 7 8 9 Height m ft Floor distance m ft C F 1 0 3 3 2 0 6 6 3 0 9 9 3 2 10 5 5 16 4 5 16 4 3 9 9 4 13 1 4 13 1 3 9 9 2 6 6 2 6 6 1 3 3 1 3 3 0 27 81 27 81 27 81 27 81 25 77 25 77 23 73 23 73 0 Height m ft Floor distance m ft C F 1 0 3 3 2 0 6 6 3 0 9 9 3 2 10 5 5 16 4 5 16 4 3 9 9 4 13 1 4 13 1 3 9 9 2 6 6 2 6 6 1 3 3 1 3 3 0 0 26 79 26 79 26 79 26 79 26 79 26 79 24 75...

Page 22: ...gle 30 Fan mode Flow angle 70 Height m ft Floor distance m ft Floor distance m ft 0 0 m s ft s m s ft s Height m ft 0 0 PLFY P08 12 15 NCMU E 2 7 2 1 2 7 8 9 6 6 3 3 8 9 6 6 3 3 2 1 3 4 2 1 3 0 3 3 2 0 6 6 1 0 3 3 0 5 1 6 2 0 6 6 3 0 9 8 1 0 3 3 0 5 1 6 3 4 13 1 9 8 6 6 3 3 13 1 9 8 6 6 3 3 2 1 ...

Page 23: ...loor distance m ft m s ft s 2 0 6 6 2 0 6 6 1 0 3 3 1 0 3 3 0 5 1 6 0 5 1 6 1 5 4 9 1 5 4 9 1 5 4 9 1 5 4 9 Height m ft Floor distance m ft m s ft s 1 0 3 3 0 3 9 9 2 6 6 1 3 3 0 1 3 3 2 6 6 3 9 9 2 0 6 6 2 7 8 9 1 0 3 3 1 0 3 3 0 5 1 6 0 5 1 6 1 5 4 9 1 5 4 9 2 0 6 6 2 0 6 6 2 0 6 6 2 0 6 6 2 0 6 6 2 0 6 6 0 5 1 6 0 5 1 6 0 5 1 6 0 5 1 6 0 5 1 6 0 5 1 6 Height m ft Floor distance m ft m s ft s 1 ...

Page 24: ...9 9 2 6 6 2 6 6 1 3 3 1 3 3 0 0 2 0 6 6 2 0 6 6 1 5 4 9 1 5 4 9 1 0 3 3 1 0 3 3 0 5 1 6 0 5 1 6 2 5 8 2 2 5 8 2 2 5 8 2 2 5 8 2 2 5 8 2 2 5 8 2 3 0 9 9 3 0 9 9 Height m ft Floor distance m ft m s ft s 1 0 3 3 2 0 6 6 3 0 9 9 3 2 10 5 5 16 4 5 16 4 3 9 9 4 13 1 4 13 1 3 9 9 2 6 6 2 6 6 1 3 3 1 3 3 0 0 2 0 6 6 2 0 6 6 1 0 3 3 1 0 3 3 0 5 1 6 0 5 1 6 0 5 1 6 0 5 1 6 2 5 8 2 2 5 8 2 2 5 8 2 2 5 8 2 2 ...

Page 25: ...rring hole 3 15 16 Burring hole pitch 2 7 8 Cut out hole Ceiling surface 120 1 2 0 4 21 32 whole air amount to prevent dew dripping PLFY E P08 12 15 18 24 30 36 48NEMU E At the time of installation use the duct holes cut out located at the positions shown in following diagram as and when required A fresh air intake hole for the optional multi function casement can also be made Note The figures mar...

Page 26: ...air intake duct system for air flow amount Q Pa in W G 10 2 E Static pressure of indoor unit with air flow amount Q Pa in W G 10 2 Qa Estimated amount of fresh air intake without D CMM CFM How to read curves 200 80 150 60 100 40 50 20 0 50 20 0 1 2 50 100 150 200 CFM 3 4 5 6 CMM 2 inlet 1 inlet Air flow rate Static pressure Pa in W G 10 2 200 80 150 60 100 40 50 20 0 50 20 0 1 2 50 100 150 200 CFM...

Page 27: ...ir intake duct system for air flow amount Q Pa in W G 10 2 E Static pressure of indoor unit with air flow amount Q Pa in W G 10 2 Qa Estimated amount of fresh air intake without D CMM CFM How to read curves 200 80 150 60 100 40 50 20 0 50 20 0 1 2 50 100 150 200 CFM 3 4 5 6 CMM 2 inlet 1 inlet Air flow rate Static pressure Pa in W G 10 2 200 80 150 60 100 40 50 20 0 50 20 0 1 2 50 100 150 200 CFM ...

Page 28: ...E PAC SH59KF E Multi function casement PAC SJ41TM E Air outlet shutter plate PAC SJ37SP E High efficiency filter element PAC SH59KF E PAC SJ41TM E is necessary to use with filter PAC SH59KF E Using the air outlet shutter plate to block the air outlet to modify the air way from 4 to 3 or 2 With 1 PAC SJ37SP E 4 air ways can be changed to 3 With 2 PAC SJ37SP E 4 air ways can be changed to 2 Changing...

Page 29: ...ed Details should be referred to its Installation Manual Quantity 1 Shape Detailed installation information is referred in its Installation Manual Multi function casement is used for High efficiency filter element and or fresh air intake from outdoor It should be used with High efficiency filter element PAC SH59KF E Colorimetric method 65 Fresh air intake on the Multi function casement is possible...

Page 30: ... Wireless signal receiver Quantity 1 1 Shape Detailed installation information should be referred to its Installation Manual Signal receiver Using the flange for fresh air intake to connect to 100 3 15 16 inch duct The flange for fresh air intake is installed in the Multi function casement PAC SJ41TM E or indoor unit Item 1 Duct flange Quantity 1 Shape 2 Insulator 1 3 Screw 3 M4x10 Detailed instal...

Page 31: ...switch SW4 4 ON OFF For relay X use the specifications given below Operation coil Rated voltage 12VDC Power consumption 1W or less Use the diode that is recommended by the relay manufacturer at both ends of the relay coil The length of the electrical wiring for the PAC YU25HT is 2 meters 6 1 2 ft To extend this length use sheathed 2 core cable Control cable type CVV CVS CPEV or equivalent Cable si...

Page 32: ...31 ELECTRICAL CHARACTERISTICS Electrical characteristics MEE16K008_U I ELECTRICAL CHARACTERISTICS 1 Power supply for Indoor unit 32 1 1 Electrical characteristics of Indoor unit 32 ...

Page 33: ...FY EP15NEMU E 0 39 0 39 0 050 0 050 0 31 0 31 PLFY EP18NEMU E 0 43 0 43 0 050 0 050 0 34 0 34 PLFY EP24NEMU E 0 54 0 54 0 120 0 120 0 43 0 43 PLFY EP30NEMU E 0 57 0 57 0 120 0 120 0 45 0 45 PLFY EP36NEMU E 0 92 0 92 0 120 0 120 0 73 0 73 PLFY EP48NEMU E 1 27 1 27 0 120 0 120 1 01 1 01 PLFY P08NEMU E 0 31 0 31 0 050 0 050 0 25 0 25 PLFY P12NEMU E 0 33 0 33 0 050 0 050 0 26 0 26 PLFY P15NEMU E 0 36 ...

Page 34: ...ng so may cause the unit or pipes to burst or result in explosion or fire during use during repair or at the time of disposal of the unit It may also be in violation of applicable laws MITSUBISHI ELECTRIC CORPORATION cannot be held responsible for malfunctions or accidents resulting from the use of the wrong type of refrigerant Our air conditioning equipments and heat pumps contain a fluorinated g...

Reviews: