41
5. Removing the fan case
(1) Remove the eight fixing screws on the fan
case (T) to remove it.
(T)
Fig. 16
(U)
Fig. 17
Exercise caution when removing heavy parts.
4. Removing the reactor
(1) Remove the two fixing screws on the reactor
base (S) to remove it.
(S)
Fig. 15
7. Reactor, fan, and fan motor (bottom side maintenance)
1. Remove the control box cover according to the
procedure in section 1.
2. Removing the fan motor and ACL cable
(1) Disconnect the connector (CNCT1) from the INV
board and connector (CNACL) from the noise fil-
ter board. Then, disconnect the relay connector.
(2) Remove the cable through the rubber bush.
3. Removing the bottom plate
(1) Remove the ten fixing screws on the bottom plate
(R) to remove it.
(R)
Noise filter board
INV board
Fig. 14
6. Removing the fan and fan motor
(1) Remove the two fixing screws and attachment
on the fan motor (U).
(2) Pull out the fan motor in the direction of the
arrow.
HWE17030.qxd 17.11.9 16:28 Page 41