3. Operation
3.4. Fan speed setting
F1
F2
F3
F4
Cool
Room
Auto
Set temp.
Mode
Temp.
Fan
Fri
Press the [F4] button to go through the fan speeds in the following order.
Auto
3.5. Airflow direction setting
3.5.1 Navigating through the Main menu
<Accessing the Main menu>
F1
F2
F3
F4
Main
Main display:
Cursor
Page
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
<Item selection>
F1
F2
F3
F4
Main
Main display:
Cursor
Page
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
Cursor
Press the [MENU] button.
The Main menu will appear.
Press [F1] to move the cursor
down.
Press [F2] to move the cursor
up.
■ Automatic fan speed setting (For wireless remote controller)
It is necessary to set for wireless remote controller only when automatic
fan speed is not set at default setting.
It is not necessary to set for wired remote controller with automatic fan
speed at default setting.
1
Press the SET button with something sharp at the end.
Operate when display of remote controller is off.
MODEL SELECT
blinks and Model No. is lighted
A
.
2
Press the AUTO STOP
button.
blinks and setting No. is lighted
B
.
(Setting No.01: without automatic fan speed)
3
Press the temp.
buttons to set the setting No.02.
(Setting No.02: with automatic fan speed)
If you mistook the operation, press the ON/OFF button and operate
again from procedure
2
.
4
Press the SET button with something sharp at the end.
MODEL SELECT
and Model No. are lighted for 3 seconds, then turned off.
ON/OFF
TEMP
RESET
SET
CLOCK
MODEL SELECT
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
B
A
3
2
1 4
3.3. Temperature setting
<Cool, Dry, Heat, and Auto>
Cool
Room
28.5
Auto
Set temp.
Mode
Temp.
Fan
Fri
28.5
Example display
(Centigrade in 0.5-degree
increments)
F1
F2
F3
F4
Cool
Room
Auto
Set temp.
Mode
Temp.
Fan
Fri
Press the [F2] button to decrease the preset temperature, and press the
[F3] button to increase.
• Refer to the table on page 7 for the settable temperature range for dif-
ferent operation modes.
• Preset temperature range cannot be set for Fan/Ventilation operation.
• Preset temperature will be displayed either in Centigrade in 0.5- or
1-degree increments, or in Fahrenheit, depending on the indoor unit
model and the display mode setting on the remote controller.
• The available fan speeds depend on the models of connected indoor
units.
Note:
The number of available fan speeds depends on the type of unit connected.
Note also that some units do not provide an “Auto” setting.
In the following cases, the actual fan speed generated by the unit will differ
from the speed shown the remote controller display.
1. While the display is showing “STAND BY” or “DEFROST”.
2. When the temperature of the heat exchanger is low in the heat mode. (e.g.
immediately after heat operation starts)
3. In HEAT mode, when room temperature is higher than the temperature
setting.
4. In COOL mode, when room temperature is lower than the temperature
setting.
5. When the unit is in DRY mode.
01_RG79F159H01_EN.indd 8