This manual details how to install the PAC-SC51KUA power supply unit and its wiring with the centralized controller and the indoor units. 
For the information about how to install the centralized controller or the indoor units, see the appropriate installation manual.
For your safety, first read   1 Safety Precautions   described below before installing the PAC-SC51KUA.
Store this manual in as easily accessible location. Make sure that this manual will be passed on to any future PAC-SC51KUA power 
supply unit users.

1

Safety Precautions

Read all the “Safety Precautions” before installing this unit.
Follow at the “Safety Precautions” ; the information provides very important points regarding safety. 

Symbols and Terms

Specific Precautions

 WARNING

Statements identify conditions or practices that could result in personal injury or loss of life.

 CAUTION

Statements identify conditions or practices that could result in damage to the unit or other property.

 WARNING

 CAUTION

The unit must be installed by a dealer or technical 
representative.

Improper installation by an unqualified person may result in 
electric shock and fire.

Install in a location that is strong enough to withstand 
the weight of the unit.

A weak installation area may cause the unit to fall down, 
resulting in a personal injury.

Only use specified cables. Securely connect each 
cable so that the weight of the cable is not applied to 
the connectors.

Loose or improper connections may result in heat 
generation or fire.

Do not attempt to modify or repair the controller.

Modification or improper repair may result in electric shock 
or fire.
Consult your dealer when repairs are necessary.

Make sure that the unit is powered by a dedicated line.

Other appliances connected to the same line could cause 
an overload.

Make sure that there is a main power switch and 
Ground-fault interrupter.

A ready accessible breaker for power source line helps 
reduce the risk of electric shock. Installation of a breaker is 
mandatory in some area.

Precisely follow the steps detailed in this manual for 
proper installation.

Any deficiency caused by improper installation may result 
in an electric shock or fire.

All electrical work must be performed by a licensed 
technician, according to local regulations and the 
instructions detailed in this manual.

Inadequate electric circuit or any deficiency caused by 
improper installation may result in an electric shock or fire.

Ask your dealer or an authorized technician to move or 
reinstall the controller.

Improper installation may result in an electric shock or fire.

This appliance must be grounded.

Make sure to install a protect PE (ground) wire.
Do not connect the PE (ground) wire to gas or water pipes, 
lightning conductors, or telephone lines.
Improper grounding may cause an electric shock.

Securely install the cover (panel) of the PAC-SC51KUA.

If the cover (panel) is not installed properly, dust or water 
may enter the unit and may result in fire or electric shock.

Do not install the controller where there is a risk of 
flammable gas.

If the leaked gas accumulates around the controller, it may 
ignite and cause an explosion.

Do not use the controller in an environment high in oil, 
steam, or sulfuric gas.

These substances may have adverse effects on the 
performance of the controller or damage its parts.

Install so that the wires are not subjected to any 
tension.

Tension may cause the wires to break, overheating, or fire.

Do not wash the unit with water.

Doing so may cause an electric shock or malfunction.

Do not install in any area where the temperature could 
be more than 55°C (131°F) or less than -10°C (14°F). Do 
not expose to direct sunlight.

Use only a breaker and fuse of the specified capacity.

If breaker is not installed, it may cause an electric shock.
If a fuse and wire or copper wiring that has too large of a 
capacity is used, it may cause the unit to malfunction or fire.

Do not install in a place that has the potential for 
steam such as bath room or kitchen.

Steam may cause an electric shock or unit malfunction.

Do not install in any place where acidic, alkaline 
solution, special spray, or other substances are used.

Doing so may cause an electric shock or unit malfunction.

Use standard wires in compliance with the current 
capacity.

A failure to do this may result in an electric leakage, 
overheating or fire.

Do not touch any PCB (Printed Circuit Board) with 
your hand or tools. Do not allow dust to collect on the 
PCB.

Doing so may cause fire or an electric shock.

00gb_WT05372X04_7.book  Page 1  Monday, September 28, 2009  2:03 PM

Summary of Contents for PAC-SC51KUA

Page 1: ... 4 Wiring 5 1 Cover Removal and Installation 5 2 Power line 6 3 DC Power Supply and M NET Transmission Line 6 5 M NET Transmission Lines Length 10 Air Conditioner Control System Power supply unit Model PAC SC51KUA Installation Manual Before using the controller please read this Installation Manual carefully to ensure proper operation Retain this manual for future reference 00gb_WT05372X04_7 book P...

Page 2: ...ectrical work must be performed by a licensed technician according to local regulations and the instructions detailed in this manual Inadequate electric circuit or any deficiency caused by improper installation may result in an electric shock or fire Ask your dealer or an authorized technician to move or reinstall the controller Improper installation may result in an electric shock or fire This ap...

Page 3: ...C DC power supply 24VDC 5 0 0 75A Load capacity 24V Number of the loading unit AG 150A Centralized Controller 1 unit Environmental conditions Temperature Operating range 10 to 55ºC 14 to 131ºF Storage range 20 to 60ºC 4 to 140ºF Humidity 30 90 RH No condensation Dimensions 169 H 271 W 72 D mm 6 11 16 H 10 11 16 W 2 7 8 D in Weight 1 4 kg 3 1 8 lbs Installation Environment In the metal control pane...

Page 4: ... 3 3 External Dimensions TB2 TB3 TB1 271 10 11 16 90 3 9 16 155 6 1 8 130 5 1 8 169 6 11 16 72 2 7 8 T Unit mm in 00gb_WT05372X04_7 book Page 3 Monday September 28 2009 2 03 PM ...

Page 5: ...arately Refer to the AG 150A Installation Manual for details Field supplied Parts Specification Attachment screw M4 screw 4 pieces For wall mounting the unit Power cable Ground cable Use sheathed vinyl cord or wire Wire type Wire should not be lighter than standard PVC sheathed flexible cord IEC 60227 designation 60227 IEC 53 Wire size 0 75mm to 2mm AWG18 to 14 Main power switch Breaker for wiring...

Page 6: ...t be performed according to local regulations Improper electrical work may result in electric shock or fire Be sure to shut off the power source of this unit and all other connected units before wiring CAUTION Do not connect the AC power line to the M NET and POWER 24VDC terminal blocks of this device otherwise the unit may fail Refer to the AG 150A Installation Manual for instructions on how to i...

Page 7: ...ble 2 Use L N in EU Use L1 L2 in the U S Use a ring terminal to connect to the terminal block Fig 4 2 Ground terminal Power cable 1 1 Install ground fault interrupter and breaker for wiring on the power supply 2 Do not use anything other than a breaker and fuse with the correct capacity Using a fuse or wire of too large capacity may cause malfunction or fire 3 Note When installing the unit use the...

Page 8: ...xture CAUTION Both of PAC SC51KUA and Outdoor unit can supply DC power to the M NET transmission line Set the outdoor unit central control system transmission line power supply to the factory setting CN41 no supply For further details refer to the outdoor unit installation manual Failure to do so may cause unit malfunction or fire Power supply unit PAC SC51KUA Centralized controller AG 150A M NETt...

Page 9: ... 24VDC Power supply unit PAC SC51KUA Centralized controller AG 150A Cable Clamp DC power supply line 24VDC Polarized Use a ring terminal to connect to the terminal block Back of controller 50 m 164 ft or less Fig 4 5 Function earthing ground line DC power supply line Polarity Power supply unit DC power supply line Polarity HUB LAN PAC YG50ECA TB7 OUTDOOR UNIT 00gb_WT05372X04_7 book Page 8 Monday S...

Page 10: ... controller AG 150A Only use the M NET output TB2 or CN1 CAUTION The 24 VDC power supply is for exclusive use with the centralized controller AG 150A Power supply unit PAC SC51KUA Centralized controller AG 150A DC power supply line 24VDC Polarized DC power supply line 24VDC Polarized Fig 4 6 00gb_WT05372X04_7 book Page 9 Monday September 28 2009 2 03 PM ...

Page 11: ...pment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equip...

Page 12: ... Paper Please be sure to put the contact address telephone number on this manual before handing it to the customer This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC 00gb_WT05372X04_7 book Page 11...

Reviews: