8. Electrical work

Power supply from Outdoor unit

Power supply

Supply power separately to branch box and outdoor unit

Power supply

L

N

Isolator (Switch)

L

N

Outdoor unit

L

N

B1

B2

L

N

Branch box

S1

S2

S3

S1

S2

S3

"A

-

control

Indoor unit"

3 pole isolator
(Switch)

2 pole isolator
(Switch)

L

N

Isolator (Switch)

L

N

Branch box

S1

S2

S3

S1

S2

S3

"A

-

control

Indoor unit"

3 pole isolator
(Switch)

L

N

 

 Caution:

After  using  the  isolator,  be  sure  to  turn  off  and  on  the  main  power  supply  to  reset  the  system.  Otherwise,  the  outdoor  unit  may  not  be  able  to  detect  the 
branch box(es) or indoor units.

 Warning:

In case of A-control wiring, there is high voltage potential on the S3 terminal caused by electrical circuit design that has no electrical insulation between power 
line and communication signal line. Therefore, please turn off the main power supply when servicing. And do not touch the S1, S2, S3 terminals when the power 
is energized. If isolator should be used between outdoor unit and branch box/indoor unit and branch box, please use 2-pole or 3-pole type, as shown in the  
following figures.

Condition: Branch Box ×  + SEZ-M

DA × 5, C=8 (refer to right sample chart)

F = 5.1 × /8  +  19.8 × 5/8 

=  13.65

*3 Current sensitivity is calculated using the following formula.
 G1 = V + V3 × (Wire length[km])

G1

Current sensitivity

30 or less

30 mA  0.1sec or less

100 or less

100 mA  0.1sec or less

Wire thickness (mm

)

V3

1.5

48

.5

56

4.0

66

When connecting 3 units of the PLA-RP series respectively to the Branch Box 
1.5mm

 using 0m of wiring and connecting the Branch Box and PEFY-VMA to 

a single breaker using wiring totaling 100m in length;

G1 = .4 × 3 + 3 + 1.6 + 48 × 0.0 × 3 + 56 × 0.1

=  0.8

→ 30 mA Current sensitivity

*5 When the ecodan is connected, the master controller (G-50A etc.) cannot be connected.

6000

600

60

10

Tripping Time [s]

1

0.1

0.01

1

2

Rated Tripping current (x)

3 4

6 8

C

10

20

SAMPLE

Sample chart

Total operating current of the indoor unit

Minimum wire thickness (mm²)

Capacity (A)

Fuse (A)

Breaker for wiring 

(NFB)

Ground-fault interrupter *1

Main cable

Branch

Ground

F0 = 16A or less *

1.5

1.5

1.5

16

16

0

0A current sensitivity *3

F0 = 5A or less *

.5

.5

.5

5

5

30

30A current sensitivity *3

F0 = 3A or less *

4.0

4.0

4.0

3

3

40

40A current sensitivity *3

Apply to IEC61000-3-3 about max. permissive system impedance.
*1  The Ground-fault interrupter should support inverter circuit.

The Ground-fault interrupter should combine using of local switch or wiring breaker.

*  Take the larger of F1 or F as the value for F0. 
F1 = Total operating maximum current of the indoor units × 1.
F = (V1/C)

Connect to Branch box (PAC-MK•BC(B))

Indoor unit

V1

V

Type 1

SEZ-KD•VAQ(L), SEZ-M•DA(L), PCA-RP•KAQ, PCA-M•KA, 

SLZ-KF•VA, SLZ-M•FA, PLA-RP•BA, PLA-RP•EA

19.8

.4

Type 

PEAD-RP•JAQ(L), PEAD-M•JA(L)

6.9

Type 3

MLZ-KA•VA

9.9

Type 4

MSZ-FH•VE, MSZ-GF•VE, MSZ-SF•VE, MSZ-EF•VE,  

MSZ-SF•VA, MSZ-AP•VF

6.8

Type 5

MFZ-KJ•VE, MSZ-LN•VG, MSZ-AP•VG, MLZ-KP•VF

7.4

Type 6

Branch box (PAC-MK•BC(B))

5.1

3.0

Type 7

ecodan C generation*5

5.1

5.0*

*This value may increase due to a locally connected actuator.
C : Multiple of tripping current at tripping time 0.01s
Please pick up "C" from the tripping characteristic of the breaker.

►  As for types not listed in the left-side table for indoor units connected 

to  the  branch  box,  refer  to  the  attached  sheet,  “Criteria  for  selecting 
breaker when branch box is fed from separate power source”.

►  As to coefficient (V1, V2) of the LEV kit connected indoor unit and City 

Multi indoor unit, refer to the outdoor unit INSTALLATION MANUAL.

Summary of Contents for PAC-MK33BC

Page 1: ...H BOX PAC MK53BC PAC MK33BC ONLY FOR R410A OUTDOOR UNIT ONLY FOR INDOOR USE HFC utilized R410A INSTALLATION MANUAL For safe and correct use please read this installation manual thoroughly before installing the air conditioner unit English FOR INSTALLER ...

Page 2: ... ground or a poor electrical contact at the intermediate connection point If an intermediate connection is necessary be sure to take measures to prevent water from entering the cords and wires Caution Make sure that the refrigerant pipes are well insulated to prevent condensa tion Incomplete insulation may cause condensation on the surface of pipes wetting of the ceiling floor and other important ...

Page 3: ...it use optional different diameter de formed joints to the branch box side Connect deformed joint directly to the branch box side A Suspension bolt pitch B To indoor unit C To outdoor unit D Service panel E Electric cover F Rubber bush G Terminal block to indoor unit on control board H Terminal block to outdoor unit J Terminal block for communication cable K Cable clamp PAC MK53BC Fig 4 2 Suspensi...

Page 4: ...unit A B C Liquid pipe ø6 35 ø6 35 ø6 35 ø9 52 Gas pipe ø9 52 ø9 52 ø9 52 ø15 88 320 402 12 24 A A B C B C CAP CAP 72 90 25 25 209 170 47 65 25 70 70 450 112 70 87 280 40 96 83 TB2B TB5 TB3B TB3C TB3A A A B C D K F E H G J Fig 4 3 4 1 The direction of the piping can be changed Fig 4 4 Fig 4 4 1 Remove the screws in each part 4 2 Piping direction change work procedures Fig 4 5 1 8 mm Fig 4 5 ...

Page 5: ...pposite surface B Service panel B 7 Install the electric cover on the opposite surface A Electric cover A Fig 4 5 4 Dimensions and required servicing space of Branch Box 2 Remove the electric cover service panel and top panel A Electric cover B Service panel C Top panel B A C 3 Install the top panel on the opposite surface C Top panel C ...

Page 6: ...nsion valve coils and sensors from a maintenance hole becomes difficult Only exchange work of a PCB is possible 3 Top View Fig 4 10 2 The space when installing on the floor Fig 4 11 3 The space when installing on a wall Fig 4 12 Warning The installation direction is limited when installing on a wall Fig 4 13 Correct installation direction When installing the unit on the wall install the piping con...

Page 7: ...surface of the insulation material Insulation material Heat resistant temperature 120 C Thickness 15 mm or more When the refrigerant piping is used in locations subject to high temperature and humidity such as in the attic further addition of insulation may be re quired Insulate the liquid and gas pipes of the branch box by attaching the heat resis tant polyethylene foam tightly around them Fig 7 ...

Page 8: ...0 ø1 7 50 Refrigerant charge Refer to the installation manual of the outdoor unit Use only R410A refrigerant use of other refrigerants may cause troubles Caution To avoid excessive strain on the branch box support the piping with one or more support s 1 5 m or less from the branch box Refer to Fig 7 6 as an example J Refrigerant piping L Thermal insulation for refrigerant piping mm Fig 7 4 C D 3 6...

Page 9: ...that wiring installed in the ceiling is chewed by rats etc it should be installed in wiring conduit 1 Remove the electric cover Fig 8 1 2 Pass the wiring into the branch box each wire in place with a wiring clamp 3 Firmly connect each wire to the appropriate terminal block Fig 8 8 4 Set dip sw Refer to 8 3 5 Replace the electric cover Fig 8 1 Fig 8 2 Fig 8 3 Fig 8 4 B 1 5 m or less Support Fig 8 7...

Page 10: ...or unit Circuit breaker indoor unit C indoor unit D indoor unit C indoor unit A indoor unit B indoor unit E indoor unit A indoor unit B Indoor unit M NET Branch BOX 2 3 branches type Pull box M NET Branch BOX 1 5 branches type L B1 B2 M1 M2 L N TB3A N TB3B TB3C TB3 TB2B TB5 TB3A TB3B TB3C TB2B TB5 L N M1 M2 S E B C C C C C C C C M1 M2 S S1 S2 S3 S1 S2 S3 S1 S2 S3 S1 S2 S3 S1 S2 S3 S1 S2 S3 S1 S2 S...

Page 11: ...power supply method Outdoor unit Power supply from outdoor unit Separate power supply 1 phase power supply Unnecessary Necessary 3 phase power supply Necessary Necessary 9 Recommended Connection Method When connecting one indoor unit to the branch box connect it to TB3A When connecting 2 indoor units connect them to TB3A and TB3B When connecting 3 indoor units connect them to TB3A TB3B and TB3C Co...

Page 12: ...28 30 mA Current sensitivity 5 When the ecodan is connected the master controller G 50A etc cannot be connected 6000 600 60 10 Tripping Time s 1 0 1 0 01 1 2 Rated Tripping current x 3 4 6 8 C 10 20 SAMPLE Sample chart Total operating current of the indoor unit Minimum wire thickness mm Capacity A Fuse A Breaker for wiring NFB Ground fault interrupter 1 Main cable Branch Ground F0 16A or less 2 1 ...

Page 13: ...igit Example When setting the address to 3 set the ones digit to 3 and the tens digit to 0 When setting the address to 25 set the ones digit to 5 and the tens digit to 2 Example When setting the address of the branch BOX to 3 an address is assigned to each indoor unit starting with Unit A as shown below no matter if each indoor unit is con nected SW1 1 5 ON Indoor Unit A Address 3 Indoor Unit B Ad...

Page 14: ...rigerant pipes and the indoor outdoor unit connecting wires To check for improper wiring perform the test run for each indoor unit individually Caution Use the remote controller to operate the indoor unit The following symptoms are not malfunctions Symptom Cause Indoor unit LED display Indoor unit does not operate even if set to cooling heating operation The cooling heating operation cannot be ope...

Page 15: ...ortuguese Branch Avda do Forte 10 2799 514 Carnaxide Lisbon Portugal Spanish Branch Carretera de Rubi 76 80 Apdo 420 08173 Sant Cugat del Valles Barcelona Spain Scandinavian Branch Hammarbacken 14 P O Box 750 SE 19127 Sollentuna Sweden UK Branch Travellers Lane Hatfield Herts AL10 8XB England U K Polish Branch Krakowska 50 PL 32 083 Balice Poland MITSUBISHI ELECTRIC TURKEY ELEKTRİK ÜRÜNLERI A Ş Şe...

Reviews: