![Mitsubishi Electric MUZ-GA50VA Service Manual Download Page 6](http://html.mh-extra.com/html/mitsubishi-electric/muz-ga50va/muz-ga50va_service-manual_1810927006.webp)
6
PART NAMES AND FUNCTIONS
2
Air inlet
Piping
Air outlet
(back and side)
Drain hose
Drain outlet
ACCESSORIES
1
2
Drain socket
Drain cap
[
33
1
2
E1
E2
E3
Single phase
230V,50Hz
20
7.46
0.30
SNB130FLDH or SNB130FLDH1
850
U-V 0.45 W-U 0.45
V-W 0.45
RC0J60-AA
BLK-WHT 15.2
WHT-RED 15.2 RED-BLK15.2
840
o
850
o
330
53
2
1.8
NEO22
Cooling
5.0(0.9-5.9)
2.5
2,940/1,650
6.23
1,410
98.4
5.93
3.42
53/51
800/480
Heating
5.9(0.9-7.8)
—
2,940/2,210
7.01
1,580
98.0
6.71
3.62
55/53
800/620
Outdoor model
Function
Power supply
Capacity Rated frequency(Min.-Max.)
Dehumidification
Air flow(High/Low)
Power outlet
Running current
Power input
Power factor
Starting current
✽
1
Compressor motor current
✽
1
Fan motor current
Model
Output
Winding
resistance(at 20
:
)
Model
Winding
resistance(at 20
:
)
Dimensions W
O
H
O
D
Weight
Sound level(High/Low)
Fan speed(High/Low)
Fan speed regulator
Refrigerant filling
capacity(R410A)
Refrigeration oil(Model)
kW
r
/h
K
/h
A
A
W
%
A
A
A
W
"
"
mm
kg
dB
rpm
kg
Compressor
Fan
motor
Special
remarks
Coefficient of performance(C.O.P)
✽
1
Capacity
Electrical
data
Single phase
230V,50Hz
20
11.2
0.30
TNB220FMCH
1,300
U-V 1.41 W-U 1.41
V-W 1.41
RC0J60-AA
BLK-WHT 15.2
WHT-RED 15.2 RED-BLK15.2
840
o
850
o
330
58
2
2.0
NEO22
Cooling
7.1(0.9-8.3)
3.8
2,940/1,650
10.4
2,360
98.7
10.1
2.93
53/51
800/480
Heating
8.1(0.9-9.6)
—
2,940/2,210
10.6
2,390
98.0
10.3
3.31
55/53
800/620
MUZ-GA71VA
Single phase
230V,50Hz
20
8.93
0.30
SNB130FLDH or SNB130FLDH1
SNB130FLEH1
SNB130FGBH
850
U-V 0.45 W-U 0.45
V-W 0.45
RC0J60-AA
BLK-WHT 15.2
WHT-RED 15.2 RED-BLK15.2
840
o
850
o
330
53
2
1.8
NEO22
Cooling
6.0(0.9-6.7)
3.0
2,940/1,650
8.23
1,870
98.8
7.93
3.11
53/51
800/480
Heating
6.8(0.9-8.1)
—
2,940/2,210
8.33
1,880
98.1
8.03
3.51
55/53
800/620
MUZ-GA60VA
MUZ-GA50VA
NOTE : Test conditions are based on ISO 5151.
Cooling : Indoor
DB 27
:
WB 19
:
Outdoor DB 35
:
WB (24
:
)
Heating : Indoor
DB 20
:
WB 15
:
Outdoor DB 7
:
WB 6
:
Refrigerant piping length (one way): 5m
✽
1 Measured under rated operating frequency.
3
SPECIFICATION
MUZ-GA50VA
MUZ-GA60VA
MUZ-GA71VA