3. Outdoor power board
325-370V DC
Output
(Red)
(White)
Connect to the compressor
Voltage among phases: 5V to
180V
Connect to the earth
CN5
Primary current detection
(Connect to the noise filter)
CN2
Connect to the controller board
(+)1-5(–): Signal transmission
(To electronic control P.C. board)
5V DC pulse wave
(+)2-5(–): Zero cross signal
3-4 : Not used
(+)6-5(–): 15V
(+)7-5(–): 15V
(+)
(–)
Signal reception (From
electronic control P.C. board)
5V DC pulse wave
)
CN3
Fin temperature thermistor RT64
325-370V DC
Output
(Red)
(White)
Connect to the compressor
Voltage among phases: 5V to 180V
Connect to the earth
CN5
Primary current detection
(Connect to the noise filter)
CN2
Connect to the controller board
(+)1-5(–): Signal transmission
(To electronic control P.C. board)
5V DC pulse wave
(+)2-5(–): Zero cross signal
3-4 : Not used
(+)6-5(–): 15V
(+)7-5(–): 15V
(+)
(–)
Signal reception (From
electronic control P.C. board)
5V DC pulse wave
)
CN3
Fin temperature thermistor RT64
1
3
1
3