13
MUZ-GA71VA
Unit: mm
Outdoor
heat
exchanger
Flared connection
Defrost
thermistor
RT61
Discharge
temperature
thermistor
RT62
Flared connection
Stop valve
Stop valve
(with service port)
Capillary tube
Ø3.6 x Ø2.4 x 50
Capillary tube
Ø1.8 x Ø0.6 x 1000
Refrigerant flow in cooling
Compressor
4-way valve
Refrigerant flow in heating
Refrigerant pipe Ø15.88
(with heat insulator)
Refrigerant pipe Ø9.52
(with heat insulator)
LEV
R.V. coil
heating ON
cooling OFF
Oil separator High-pressure
switch
Strainer
#100
Receiver
Outdoor
heat
exchanger
temperature
thermistor
RT68
Strainer
#100
Strainer
#100
Ambient
temperature
thermistor
RT65
MUZ-GA60VA -
E3
Unit: mm
Outdoor
heat
exchanger
Flared connection
Defrost
thermistor
RT61
Discharge
temperature
thermistor
RT62
Flared connection
Stop valve
Stop valve
(with service port)
Capillary tube
Ø3.6 x Ø2.4 x 50
Refrigerant flow in cooling
Compressor
4-way valve
Refrigerant flow in heating
Refrigerant pipe Ø15.88
(with heat insulator)
Refrigerant pipe Ø6.35
(with heat insulator)
LEV
R.V. coil
heating ON
cooling OFF
Muffler
#100
Strainer
#100
Receiver
Outdoor heat
exchanger
temperature
thermistor
RT68
Ambient
temperature
thermistor
RT65
Strainer
#100
High-pressure
switch
Summary of Contents for MUZ-GA50VA-E1
Page 10: ...10 MUZ GA60VA E3 ...