34
12
DISASSEMBLY INSTRUCTIONS
OPERATING PROCEDURE
PHOTOS
Photo 1
1. Removing the cabinet.
(1) Remove the screws fixing the top panel. (Photo 1)
(2) Remove the top panel. (Photo 1)
(3) Remove the screw fixing the service panel. (Photo 2)
(4) Pull down the service panel and remove it. (Photo 2)
(5) Remove the screws fixing the cabinet.
(6) Remove the cabinet.
(7) Disconnect the indoor/outdoor connecting wire.
(8) Remove the screws fixing the back panel.
(9) Remove the back panel.
Screws of
the cabinet
(1) Slide the sleeve and check if there is a locking lever or not.
(2) The terminal with this connector is a terminal
with lock mechanism
1
Slide the sleeve.
2
Pull the terminal while
pushing the locking
lever.
1
Hold the sleeve, and
pull out the terminal
slowly.
In case of terminal with lock mechanism, detach the terminal as shown below.
There are two types ( Refer to (1) and (2)) of the terminal with lock mechanism.
The terminal with no lock mechanism can be removed by pulling it out.
Check the shape of the terminal and work.
<"Terminal with lock mechanism" Detaching points>
Connector
Sleeve
Locking lever
Photo 2
Screw of the
service panel
Direction to
remove
Hooks
Screws of
the top panel
Back
panel
Service
panel
MUZ-A09YV -
MUZ-A12YV -
MUZ-A09YVH -
MUZ-A12YVH -
OUTDOOR UNIT
E1
E1
E1
E1
Screws of
the top panel
Screws of
the cabinet
OB328A --2qxp 04.4.26 4:50 PM Page 34